Point-of-care ultrasound is increasingly used at the bedside to integrate the clinical assessment of the critically ill; in particular, lung ultrasound has greatly developed in the last decade. This review describes basic lung ultrasound signs and focuses on their applications in critical care. Lung semiotics are composed of artifacts (derived by air/tissue interface) and real images (i.e., effusions and consolidations), both providing significant information to identify the main acute respiratory disorders. Lung ultrasound signs, either alone or combined with other point-of-care ultrasound techniques, are helpful in the diagnostic approach to patients with acute respiratory failure, circulatory shock, or cardiac arrest. Moreover, a semiquantification of lung aeration can be performed at the bedside and used in mechanically ventilated patients to guide positive end-expiratory pressure setting, assess the efficacy of treatments, monitor the evolution of the respiratory disorder, and help the weaning process. Finally, lung ultrasound can be used for early detection and management of respiratory complications under mechanical ventilation, such as pneumothorax, ventilator-associated pneumonia, atelectasis, and pleural effusions. Lung ultrasound is a useful diagnostic and monitoring tool that might in the near future become part of the basic knowledge of physicians caring for the critically ill patient.
In the intensive care unit, patient lung ultrasound provides accurate information on lung morphology with diagnostic and therapeutic relevance. It enables clinicians easy, rapid, and reliable evaluation of lung aeration and its variations at the bedside. Supplemental Digital Content is available in the text.
Objectives: Lung ultrasound is commonly used to evaluate lung morphology in patients with acute respiratory distress syndrome. Aim of this study was to determine lung ultrasound reliability in assessing lung aeration and positive end-expiratory pressure–induced recruitment compared with CT. Design: Randomized crossover study. Setting: University hospital ICU. Patients: Twenty sedated paralyzed acute respiratory distress syndrome patients: age 56 years (43–72 yr), body mass index 25 kg/m2 (22–27 kg/m2), and Pao 2/Fio 2 160 (113–218). Interventions: Lung CT and lung ultrasound examination were performed at positive end-expiratory pressure 5 and 15 cm H2O. Measurements and Main Results: Global and regional Lung Ultrasound scores were compared with CT quantitative analysis. Lung recruitment (i.e., decrease in not aerated tissue as assessed with CT) was compared with global Lung Ultrasound score variations. Global Lung Ultrasound score was strongly associated with average lung tissue density at positive end-expiratory pressure 5 (R2 = 0.78; p < 0.0001) and positive end-expiratory pressure 15 (R2 = 0.62; p < 0.0001). Regional Lung Ultrasound score strongly correlated with tissue density at positive end-expiratory pressure 5 (rs = 0.79; p < 0.0001) and positive end-expiratory pressure 15 (rs = 0.79; p < 0.0001). Each step increase of regional Lung Ultrasound score was associated with significant increase of tissue density (p < 0.005). A substantial agreement was found between regional Lung Ultrasound score and CT classification at positive end-expiratory pressure 5 (k = 0.69 [0.63–0.75]) and at positive end-expiratory pressure 15 (k = 0.70 [0.64–0.75]). At positive end-expiratory pressure 15, both global Lung Ultrasound score (22 [16–27] vs 26 [21–29]; p < 0.0001) and not aerated tissue (42% [25–57%] vs 52% [39–67%]; p < 0.0001) decreased. However, Lung Ultrasound score variations were not associated with lung recruitment (R2 = 0.01; p = 0.67). Conclusions: Lung Ultrasound score is a valid tool to assess regional and global lung aeration. Global Lung Ultrasound score variations should not be used for bedside assessment of positive end-expiratory pressure–induced recruitment.
Lung ultrasound is increasingly used in emergency departments, medical wards, and critical care units—adult, pediatric, and neonatal. In vitro and in vivo studies show that the number and type of artifacts visualized change with lung density. This has led to the idea of a quantitative lung ultrasound approach, opening up new prospects for use not only as a diagnostic but also as a monitoring tool. Consequently, the multiple scoring systems proposed in the last few years have different technical approaches and specific clinical indications, adaptable for more or less time-dependent patients. However, multiple scoring systems may generate confusion among physicians aiming at introducing lung ultrasound in their clinical practice. This review describes the various lung ultrasound scoring systems and aims to clarify their use in different settings, focusing on technical aspects, validation with reference techniques, and clinical applications.