Yun F. Wang

Dr. Yun F. Wang


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2013 in Journal of Clinical Microbiology
Verified
Journal Article
Open access
PDF file
AFAmy Fothergill
Amy Fothergill
VKVyjayanti Kasinathan
Vyjayanti Kasinathan
JHJay Hyman
Jay Hyman
JWJohn Walsh
John Walsh
TDTim Drake
Tim Drake
YWYun F. Wang
Yun F. Wang
Rapid identification of microorganisms causing bloodstream infections directly from a positive blood culture would decrease the time to directed antimicrobial therapy and greatly improve patient care. Matrix-assisted laser desorption ionization–time of flight (MALDI-TOF) mass spectrometry (MS) is a fast and reliable method for identifying microorganisms from positive culture. This study evaluates the performance of a novel filtration-based method for processing positive-blood-culture broth for immediate identification of microorganisms by MALDI-TOF with a Vitek MS research-use-only system (VMS). BacT/Alert non-charcoal-based blood culture bottles that were flagged positive by the BacT/Alert 3D system were included. An aliquot of positive-blood-culture broth was incubated with lysis buffer for 2 to 4 min at room temperature, the resulting lysate was filtered through a membrane, and harvested microorganisms were identified by VMS. Of the 259 bottles included in the study, VMS identified the organisms in 189 (73%) cultures to the species level and 51 (19.7%) gave no identification (ID), while 6 (2.3%) gave identifications that were considered incorrect. Among 131 monomicrobic isolates from positive-blood-culture bottles with one spot having a score of 99.9%, the IDs for 131 (100%) were correct to the species level. In 202 bottles where VMS was able to generate an ID, the IDs for 189 (93.6%) were correct to the species level, whereas the IDs provided for 7 isolates (3.5%) were incorrect. In conclusion, this method does not require centrifugation and produces a clean spectrum for VMS analysis in less than 15 min. This study demonstrates the effectiveness of the new lysis-filtration method for identifying microorganisms directly from positive-blood-culture bottles in a clinical setting.

14 February 2014 in PLOS ONE
Verified
Journal Article
Open access
PDF file
AMAlexandra Machen
Alexandra Machen
TDTim Drake
Tim Drake
YWYun F. Wang
Yun F. Wang
Rapid identification and antimicrobial susceptibility testing of microorganisms causing bloodstream infections or sepsis have the potential to improve patient care. This proof-of-principle study evaluates the Lysis-Filtration Method for identification as well as antimicrobial susceptibility testing of bacteria directly from positive blood culture bottles in a clinical setting. A total of 100 non-duplicated positive blood cultures were tested and 1012 microorganism-antimicrobial combinations were assessed. An aliquot of non-charcoal blood culture broth was incubated with lysis buffer briefly before being filtered and washed. Microorganisms recovered from the filter membrane were first identified by using Matrix-Assisted Laser Desorption/Ionization Time-of-Flight VITEK® Mass Spectrometry (VITEK MS). After quick identification from VITEK MS, filtered microorganisms were inoculated to VITEK®2 system for full panel antimicrobial susceptibility testing analysis. Of 100 bottles tested, the VITEK MS resulted in 94.0% correct organism identification to the species level. Compared to the conventional antimicrobial susceptibility testing methods, direct antimicrobial susceptibility testing from VITEK®2 resulted in 93.5% (946/1012) category agreement of antimicrobials tested, with 3.6% (36/1012) minor error, 1.7% (7/1012) major error, and 1.3% (13/1012) very major error of antimicrobials. The average time to identification and antimicrobial susceptibility testing was 11.4 hours by using the Lysis-Filtration method for both VITEK MS and VITEK®2 compared to 56.3 hours by using conventional methods (p<0.00001). Thus, the same-day results of microorganism identification and antimicrobial susceptibility testing directly from positive blood culture can be achieved and can be used for appropriate antibiotic therapy and antibiotic stewardship.

1 December 2013 in Journal of Clinical Microbiology
Verified
Journal Article
Open access
PDF file
AMAlexandra Machen
Alexandra Machen
MKMiwako Kobayashi
Miwako Kobayashi
MCMary Robin Connelly
Mary Robin Connelly
YWYun F. Wang
Yun F. Wang
Two novel protocols for inactivation and extraction were developed and used to identify 107 Mycobacterium clinical isolates, including Mycobacterium tuberculosis complex, from solid cultures using Vitek matrix-assisted laser desorption ionization–time of flight (MALDI-TOF) mass spectrometry. The protocol using heat inactivation with sonication and cell disruption with glass beads resulted in 82.2% and 88.8% species and genus level identifications, respectively.


28 April 2021 in IEEE Open Journal of Engineering in Medicine and Biology
Verified
Journal Article
Open access
ENEric J. Nehl
Eric J. Nehl
SHStacy Heilman
Stacy Heilman
DKDavid Ku
David Ku
DGDavid S. Gottfried
David S. Gottfried
SFSarah Farmer
Sarah Farmer
WLWilbur Lam
Wilbur Lam
Faced with the COVID-19 pandemic, the US system for developing and testing technologies was challenged in unparalleled ways. This article describes the multi-institutional, transdisciplinary team of the “RADx SM Tech Test Verification Core” and its role in expediting evaluations of COVID-19 testing devices. Expertise related to aspects of diagnostic testing was coordinated to evaluate testing devices with the goal of significantly expanding the ability to mass screen Americans to preserve lives and facilitate the safe return to work and school. Focal points included: laboratory and clinical device evaluation of the limit of viral detection, sensitivity, and specificity of devices in controlled and community settings; regulatory expertise to provide focused attention to barriers to device approval and distribution; usability testing from the perspective of patients and those using the tests to identify and overcome device limitations, and engineering assessment to evaluate robustness of design including human factors, manufacturability, and scalability.

25 January 2013 in Emerging Microbes & Infections
Verified
Journal Article
Open access
SHSalim S Hayek
Salim S Hayek
TAThura T Abd
Thura T Abd
SCSushma K Cribbs
Sushma K Cribbs
AAAlbert M Anderson
Albert M Anderson
AMAndre Melendez
Andre Melendez
YWYun F. Wang
Yun F. Wang
Though Elizabethkingia meningosepticum typically causes meningitis in neonates, its occurrence in adult is rare, with sixteen cases described worldwide. We report a case of E. meningosepticum meningitis in an immunocompetent adult. Bacterial identification was made a day earlier than conventional method by using matrix assisted laser desorption ionization time-of-flight (MALDI-TOF) Vitek mass spectrometry RUO (VMS), which resulted in successful treatment with rifampin, trimethoprim-sulfamethoxazole, levofloxacin and minocycline.Emerging Microbes & Infections (2013) 2, e17; doi:10.1038/emi.2013.16