Andreas Hain

Dr. Andreas Hain


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 November 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
JYJoerg Yogarajah
Joerg Yogarajah
JHJulie Hutter
Julie Hutter
PKPatrick Kahle
Patrick Kahle
PBPhilipp Beaujean
Philipp Beaujean
MTMarko Tomic
Marko Tomic
TNThomas Neumann
Thomas Neumann
Background and Aims: Various pulsed field ablation (PFA) systems are currently being developed. Recently, a novel CE-approved circular array PFA catheter (PulseSelect™ PFA System, Medtronic, Minneapolis, MN, USA) was introduced. Data on this commercially available system are sparse. The aim was to elucidate real-world data assessing the feasibility, safety, and acute efficacy of pulmonary vein isolation (PVI) and ablation beyond PVI with this novel ablation system. Methods: Consecutive patients with paroxysmal and persistent atrial fibrillation (AF) undergoing first-time ablation with the circular PFA catheter were enrolled in this study. In patients with persistent AF and left atrial (LA) enlargement (LA area > 20 cm2), additional left atrial roof ablation (LARA) was performed. Those with concomitant typical atrial flutter received adjunctive cavo-tricuspid isthmus (CTI) ablation. Results: A total of 100 AF patients were included (29% female, 50% persistent AF). Of these, 33 patients (33%) underwent adjunctive LARA, 1 patient (1%) received posterior wall isolation, and 6 patients (6%) required additional CTI ablation. The skin-to-skin procedural time averaged 66.3 ± 13.8 min, while the fluoroscopy time and dose area product were 13.7 ± 4.7 min and 6.8 ± 4.9 Gycm2, respectively. Acute PVI was achieved in 100% of pulmonary veins. A bidirectional conduction block of the LARA and CTI lines was confirmed in all patients, and no major adverse events were reported. Conclusions: These real-world data demonstrate the feasibility, safety, and acute efficacy of PVI and ablation beyond PVI using a novel circular array PFA catheter in patients with atrial fibrillation and flutter. The system can easily be integrated with standard PVI workflows. Further and larger studies are warranted to assess the clinical long-term effectiveness and safety of this PFA system.

Verified
Journal Article
Open access
PDF file
AHAndreas Hain
Andreas Hain
NBNikolai Busch
Nikolai Busch
EWElias Waezsada
Elias Waezsada
JHJulie Hutter
Julie Hutter
PKPatrick Kahle
Patrick Kahle
JSJohannes Sperzel
Johannes Sperzel
Guideline-directed medical therapy (GDMT) is crucial in reducing mortality in patients with heart failure with heart rate lowering by a beta blocker (BB) being an important therapeutic concept. We aimed to assess the usefulness of a wearable cardioverter/defibrillator (WCD) to provide detailed information about heart rate for managing patients with reduced left ventricular ejection fraction (LVEF) and symptoms of heart failure and to correlate mortality with the mean heart rate. A total of 4509 consecutive patients (mean age: 59 + 13 years, 88% male) were analyzed retrospectively. All patients had reduced LVEF and were prescribed a WCD for protection from sudden cardiac death (SCD) during GDMT uptitration awaiting LVEF recovery. The device continuously measured nighttime and daytime HR at the beginning and end of WCD use. Patients who died during wear time had significantly higher HRs compared with survivors: daytime beginning of use (BOU), 80 ± 15 bpm vs. 76 ± 13, p < 0.01; nighttime BOU, 76 ± 14 vs. 69 ± 13, p < 0.0001; daytime end of use (EOU), 84 ± 20 vs. 73 ± 13, p < 0.0001; nighttime EOU, 80 ± 20 vs. 65 ± 12, p < 0.0001). In conclusion, HR monitoring with a WCD yields important prognostic information and may assist in optimal usage of BB in patients with low LVEF.

30 June 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
JWJan Sebastian Wolter
Jan Sebastian Wolter
JTJulia Treiber
Julia Treiber
SFSelina Fischer
Selina Fischer
UFUlrich Fischer-Rasokat
Ulrich Fischer-Rasokat
SKSteffen Daniel Kriechbaum
Steffen Daniel Kriechbaum
ARAndreas Rolf
Andreas Rolf
Myocardial inflammation and edema are major pathological features in myocarditis. Myocardial tissue water content and myocardial edema can be quantified via T2 mapping. Thus, cardiac magnetic resonance (CMR) is the noninvasive gold standard for diagnosing myocarditis. Several studies showed an impact of short-term volume changes on T2 relaxation time. Plasma volume status (PVS) is a good surrogate parameter to quantify a patient’s volume status, and it is simple to use. The aim of this study was to determine the effect of PVS on the diagnostic value of T2 relaxation time in myocardial inflammation. Between April 2017 and December 2022, patients who were indicated for cardiac CMR were included in our prospective clinical registry. Patients with myocardial inflammation and those with unremarkable findings were analyzed in the present study. A blood sample was drawn, and PVS was calculated. Patients were separated into PVS tertiles to explore a possible nonlinear dose–response relationship. Logistic regression analysis was used to determine whether T2 is an independent predictor of myocardial inflammation. A total of 700 patients (47.43% female) were eligible for analysis. Of these, 551 patients were healthy (78.7%), while 149 (21.3%) showed signs of myocardial inflammation. The T2 relaxation time was elevated in patients with myocardial inflammation (40 ms [IQR 37–42 ms] vs. 38.0 ms [IQR 36–39 ms], p < 0.001). PVS showed no difference between the groups (−12.94 [IQR −18.4–−7.28] vs.−12.19 [IQR −18.93–−5.87], p = 0.384). T2 showed a clear dose–response relationship with PVS, with increasing T2 values along the PVS tertiles. In spite of this, T2 was found to be an independent marker of myocardial inflammation in logistic regression (OR T2 1.3 [95% CI 1.21–1.39], p < 0.001), even after adjusting for PVS (OR T2 [adj. PVS] 1.31 [95% CI 1.22–1.40], p < 0.001). Despite a dose–response relationship between T2 and the volume status, T2 was found to be an independent indicator of myocardial inflammation.

Verified
Journal Article
Open access
PDF file
UFUlrich Fischer-Rasokat
Ulrich Fischer-Rasokat
MRMatthias Renker
Matthias Renker
CLChristoph Liebetrau
Christoph Liebetrau
MWMaren Weferling
Maren Weferling
ARAndreas Rolf
Andreas Rolf
WKWon-Keun Kim
Won-Keun Kim
Patients with symptomatic aortic stenosis (AS) can have concomitant systolic heart failure (HF) that persists even after correction of afterload by transcatheter aortic valve implantation (TAVI). These patients qualify as potential candidates for prophylactic therapy with an implantable cardioverter defibrillator (ICD). We compared survival between patients with or without an ICD after successful TAVI. This retrospective study analyzed Kaplan-Meier survival data during a follow-up period of three years in two populations: (a) patients with a left ventricular ejection fraction (LVEF) ≤ 35% before TAVI (overall population); (b) patients with additionally documented LVEF ≤ 35% 3 months after TAVI (persistent LV dysfunction subpopulation). In the overall population, 53 patients with and 193 patients without an ICD had similar baseline characteristics and procedural success rates, and HF medication at discharge was comparable. Three-year mortality rates were 26.4% for patients with an ICD and 24.4% for patients without an ICD (p = 0.758). Cardiovascular death rates were similar between groups (p = 0.914), and deaths were most often attributed to worsening of HF. Survival rates in patients with persistent LV dysfunction with an ICD (n = 24) or without an ICD (n = 59) were similar between groups (p = 0.872), with cardiovascular deaths mostly qualified as worsening HF and none as sudden cardiac death. Patients of the overall study population with biventricular pacing devices showed only a tendency to have better outcomes (p = 0.298). ICD therapy in elderly patients with AS and LV dysfunction undergoing TAVI did not demonstrate a survival benefit during a 3-year follow-up period.

18 October 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
EWElias Waezsada
Elias Waezsada
JHJulie Hutter
Julie Hutter
PKPatrick Kahle
Patrick Kahle
JYJoerg Yogarajah
Joerg Yogarajah
JSJohannes Sperzel
Johannes Sperzel
AHAndreas Hain
Andreas Hain
Heart failure with reduced ejection fraction (LV-EF < 35%) is diagnosed in app. 11,000,000 patients worldwide. For the treatment of these patients, guideline directed medical therapy has proven to reduce mortality and rehospitalization regardless of the disease’s etiology. It is implemented to treat clinical symptoms by improving the left ventricular ejection fraction. Patients with a transient risk of ventricular tachycardia and sudden cardiac death can be protected by a defibrillator vest. The defibrillator vest is capable to detect and terminate ventricular arrhythmias during Guideline Directed Medical Therapy (GDMT). It is based on the recommendations of the European society of cardiology for 3 months. Afterwards, the WCD wear time could be prolonged, or, in case of persistent low ejection fraction (LV-EF ≤ 35%), an implantable cardioverter defibrillator (ICD) should be implanted, as shown in the WEARIT-II-registry. Our goal was to evaluate the effects of GDMT on LV-recovery and reduction of ICD implantations under protection with a defibrillator vest—depending on the uptitration of GDMT. Methods: 339 consecutive patients between August 2017 and September 2020 with newly diagnosed cardiomyopathy and an EF ≤ 35% were analyzed retrospectively by chart review. All patients were protected by a wearable cardioverter defibrillator (WCD). GDMT as recommended by the ESC started at discharge from hospital. The left ventricular ejection fraction (LV-EF) was determined by transthoracic echocardiography at week 4, 8 and at week 12 (in case of prolonged WCD wear time). Uptitration was performed after 4 and 8 weeks during patient visits. We focused on baseline medication as per GDMT and the dosage increase at week 4, 8 and 12. The aim was the uptitration to the maximum dosage tolerated by the patient. We also compared the LV-EF improvement in the group with and without uptitration of medication dosage. Results: The patient age was, on average, 63.2 years (SD ± 11.9 years). A total of 129 pts (38%) had ICM, 196 (58%) had NICM (incl 66 pts (19%) with DCM and 51 pts (15%) with Myocarditis, 79 pts (24%) with unknown origin) and 14 pts (4%) had other entities (e.g., Tachycardiomyopathy). In total, 21 pts (6%) had an LV-EF of less than 16%, 130 pts (38%) between 16–25% and 183 pts (54%) between 26–35%. GDMT started at discharge from the hospital included treatment with beta blocker for 327 pts (96.5%), ACE-inhibitors/Angiotensin/ARNI for 283 pts (83.5%) and Mineralcorticoid receptor antagonists (MRA) for 334 pts (88.4%). Uptitration was performed in all groups at a rate of 82.3%, 91.1% and 81.0% after 4 weeks and 64.7%, 50.3% and 66.3% after 8 weeks, respectively. After 4 weeks, 25 pts (7.4%) and, after 8 weeks, 171 pts (50.4%) had an EF increase of 5% or more (mean 14.2%). After 4 weeks, 81 patients had an LV-EF more than 35%. A total of 169 pts had a wear time of 12 weeks and an improvement of LVEF of more than 35%. Interestingly, in our study we did not find a significant difference in LV-EF improvement between the group with no uptitration and the group with uptitration. Conclusions: Guideline-directed medical therapy under protection with a WCD from ventricular arrhythmia can reduce the need for implantation of an ICD and can lead to an improvement of ejection fraction. Interestingly, the LV-EF improvement depends on the GDMT at discharge. Current guidelines recommend an initiation of all therapy columns of GDMT (sacubitril/valsartan, ACE-inhibitor/AT1-blocker, mineralcorticoidreceptorblocker, beta blocker) at once and further uptitration to the maximal dosage (ESC Guidelines 2021). A further uptitration of all drugs of GDMT should lead to improvement of LV-EF and consequently to a reduction in ICD implantations.

16 February 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
KWKay Felix Weipert
Kay Felix Weipert
JHJulie Hutter
Julie Hutter
MKMalte Kuniss
Malte Kuniss
PKPatrick Kahle
Patrick Kahle
JYJoerg Yogarajah
Joerg Yogarajah
TNThomas Neumann
Thomas Neumann
Background and Aims: Noninvasive mapping allows the identification of patient-specific atrial rotational activity (RA) that might play a key role in the perpetuation of persistent atrial fibrillation (PsAF). So far, the impact of pulmonary vein isolation by cryoballoon (Cryo-PVI) on RA is unclear. Moreover, the long-term effect of periprocedural termination of AF during the ablation procedure is controversial. Methods: Noninvasive electrocardiographic mapping with a 252-electrode vest was performed in 42 patients with PsAF. After the first analysis, Cryo-PVI was performed. The RA was analyzed again and then targeted by radiofrequency catheter ablation. The primary clinical endpoint was periprocedural termination of AF. The secondary endpoint was freedom from any atrial arrhythmia >30 s during a 12-month follow-up. Results: In 33 patients (79%), right atrial RA was identified leading to biatrial ablation, and nine patients (21%) had left atrial RA only. Twelve patients (28.6%) converted from AF to sinus rhythm (SR) (Group A). Thirteen patients (30.9%) converted to atrial tachycardia (AT) (Group B). In 17 patients (40.5%), AF was not terminated by ablation (Group C). After a mean follow-up time of 13.8 months, 26 patients were free from AF and AT (61.9%). In terms of rhythm, control Group A (75%) and B (83.3%) showed higher success rates than Group C (33.3%) (p < 0.01). Cryo-PVI had no substantial impact on RA. Conclusions: The RA-based ablation approach showed acceptable success rates. Periprocedural termination of AF had a positive predictive impact on the outcome. No difference was observed between conversion to SR or to AT. Cryo-PVI had no impact on RA.