Microwave ablation is used to treat lung tumors by releasing microwave magnetic field to produce high temperature of more than 60 ℃ in the tumor tissues, thus causing tissue coagulation, dehydration and necrosis to achieve the purpose of treatment. However, the lack of appropriate power and time parameters for microwave ablation in clinical treatment of lung tumors leads to poor ablation or excessive ablation. In this paper, a two-dimensional simulation model of microwave antenna and ideal lung was established to realize the simulation of microwave ablation process. Meanwhile, microwave ablation experiments were carried out in ex-vivo porcine lung under different power and time. The temperature distribution was obtained by thermocouples and compared with the simulation calculation. Set 60℃ as boundary of the ablation area and the ablation time was 360 s. The length of the ablation area parallel to the antenna direction is longitudinal, and the length perpendicular to the antenna direction is transverse. From the simulation results, with the increase of ablation power (20 W to 60 W), the transverse diameter of ablation area increased from 32.5 mm to 55.6 mm, and the longitudinal diameter increased from 47.8 mm to 69.1 mm. From the results of ex-vivo experiments, with the increase of ablation power (30 W to 50 W), the transverse diameter of ablation area increased from 29.5 mm to 48.9 mm, the longitudinal diameter increased from 41.1 mm to 66.3 mm, and the maximum slot temperature increased from 75.6 ℃ to 106.7 ℃. The results of numerical simulation are slightly larger than those of ex-vivo experiments under the same parameters. When the average diameter of lung tumors is less than 40 mm, 30 W and 40 W ablation power can be selected. The ablation time is limited to 360 s. 50 W ablation power can be used to ablate the lesion quickly in a shorter time to achieve the same purpose. Although there are differences between ex-vivo and in vivo, the validity of the lung model and the influence of ablation parameters in the simulation are verified in this paper. The ablation area under different parameters was obtained, which served as a reference data for clinical practice. A basic study was made to consider the complex lung model and the changes of parameters with temperature in the future.
The aim of this study is to research the lesion outline and temperature field in different ways in atrial radiofrequency ablation by using finite element method. This study used the method which considered the thermal dosage to determine the boundary between viable and dead tissue, and compared to the 50 °C isotherm results in analyzing lesion outline. Besides, we used Hyperbolic equation which considered the relaxation time to calculate the temperature field and contrasted it with Pennes’ bioheat transfer equation. As the result of the comparison of the lesion outline, when the ablation time was 120 s, the isotherm of the thermal dosage was larger than the 50 °C isotherm and with the increasing of the voltage the gap increased. When the ablation voltage was 30 V, the 50 °C isotherm was larger than the thermal dosage isotherm when the ablation time was less than 160 s. The isotherms overlapped when the time was 160 s. And when the ablation time was more than 160 s, the 50 °C isotherm was less than the thermal dosage isotherm. As to the temperature field, when the ablation voltage was 30 V with the ablation time 120 s the highest temperature decided by Hyperbolic was 0.761 °C higher. The highest temperature changed with relaxation time. In most cases, the highest temperature of the Hyperbolic was higher otherwise the relaxation time was 30–40 s. It is better to use CEM43 °C to estimate the lesion outline when the ablative time within 160 s. For temperature distribution, the Hyperbolic reflects the influence of heat transmission speed, so the result is more close to the actual situation.
5 August 2021 in Electromagnetic Biology and Medicine
Renal denervation transmits radiofrequency (RF) energy through an electrode to treat resistant hypertension (RH), applying ablation in the renal artery. Several experimental studies have shown that this treatment has been used effectively to treat RH. The aim of this paper is to investigate the effect of ablation parameters (i.e., electrode length, applied voltage, ablation time, and blood flow) on the temperature distribution using a balloon-based array electrodes system. A simplified three-dimensional model including four electrodes and a balloon was established. The balloon diameter was 3 mm and placed in a 5 mm diameter renal artery for forming intra-arterial occlusion. Four electrodes were mounted on the balloon and distributed in the same plane to mimic circumferential RF ablation. Computer simulations were conducted to investigate the thermal performances of the device by setting different electrode configurations, treatment protocols, and physiological factors. The thermal performances including the thermal distribution, maximum lesion depth, length, and area were analyzed. The lesion shape of the array RF electrodes was approximately a sphere with a 100% circumference coverage rate of the renal artery. The lesion depth and length increase with each factor except for blood velocity. Increasing the electrode length from 2 to 4 mm or 2 to 6 mm, the lesion depth increases by 1.15 mm and 0.54 mm at 60 s. The corresponding lesion length increases by 2.65 mm and 2.34 mm, respectively. The range of effective lesion depth is 1.90–4.90 mm, at a voltage of 15–30 V. But the peak temperature at the arterial outer wall exceeded 100 °C when the voltage is above 25 V. In tissue, the degree of thermal injury in the 2 mm area reached 100%, but in blood was not more than 5%. There was no significant difference at different flow conditions because the difference value in lesion depth was not exceeded 0.5 mm. The results showed that the balloon-based four electrodes system is expected to overcome the difficulty of incomplete ablation. In clinical application, 2 mm-electrode is recommended to avoid long wall damage as much as possible and control the voltage below 25 V. This treatment has little thermal injury on the blood, which means it may avoid coagulation formation. Moreover, the application of this device does not need to consider the difference in individual blood velocity.
Laser interstitial thermal therapy (LITT) is an emerging clinical treatment for deep brain tumors, which is safe, minimally invasive, and effective. This paper established a three-dimensional model based on the LITT heat transfer model, including brain tissue, laser fiber, and straight tube vessels. Combining the PID control equation, diffuse approximation equation, Pennes heat transfer equation, and Murray’s law, the effect of micro-vessel radius and distance between vessels and fiber on the ablation temperature field during laser ablation was investigated by using COMSOL finite element software. The results showed that at a constant distance of 1 mm between the vessel and the fiber, the vessels with a radius of 0.1–0.2 mm could be completely coagulated, the vessels with a radius of 0.3–0.6 mm had cooling and directional effects on temperature distribution and thermal damage, and the vessels with a radius of 0.7–1.0 mm had cooling effects on the ablation temperature. When the vessel-fiber spacing was raised by 2 mm, 0.3–0.4 mm, vasculature had a directional influence on the temperature field; when the vessel-fiber spacing was raised by 3 mm, only 0.3 mm vessels had a directional effect on the temperature field. The range of temperature field impacted by blood flow diminishes as the distance between the optical fiber and the blood artery grows. The ablation zone eventually tends to be left and right symmetrical. In this study, we simulated the LITT ablation temperature field model influenced by tiny vessels based on PID control. We initially classified the vessels, which provided some guidance for accurate prediction and helped the accuracy of preoperative planning.
1 January 2010 in International Journal of Hyperthermia
The aim of this study is to investigate the effects of an arterial bifurcation on the temperature distribution during microwave ablation in a muscle-equivalent phantom. Two experiments with water flow rates of 42.39 mL/min and 70.79 mL/min in the typical range of blood flows in the hepatic artery of the human body were implemented. Temperature measurements inside the phantom were performed in the plane of the arterial bifurcation, in each experiment the microwave antenna was placed at three different positions at 10, 15 and 20 mm from the vessel. The heating pattern was not symmetrical around the antenna with large temperature gradients near the blood vessel when the antenna was near to the vessel (10 mm): The higher the blood velocity, the smaller the heated area. The heating pattern was more circular and symmetrical, and the temperature contours with the two given flow rates nearly coincide when the antenna was far away from the blood vessel (20 mm). The temperatures near the recirculation zone in the daughter arteries immediately after the bifurcation hardly vary with blood velocity. These results indicate that the flow rate in the vessel and the distance between the vessel and the antenna can significantly affect the heating pattern during thermal ablation. The effect of blood flow on ablation is negligible if the distance between blood vessel and antenna exceeds 20 mm, and vessel occlusion can be avoided. The present results can be helpful in clinical microwave ablation surgical planning.