Josef Benedikt Weiß

Mr. Josef Benedikt Weiß

B.Braun Aesculap AG, Tuttlingen, Baden-Württemberg, Germany
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 May 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
GHGeorg Hettich
Georg Hettich
JWJosef Benedikt Weiß
Josef Benedikt Weiß
BWBenjamin Wünsch
Benjamin Wünsch
TGThomas M. Grupp
Thomas M. Grupp
In severe cases of total knee arthroplasty, where off-the-shelf implants are not suitable or available anymore (i.e., in cases with extended bone defects or periprosthetic fractures), custom-made knee implants represent one of the few remaining treatment options. Design verification and validation of such custom-made implants is very challenging. The aim of this study is to support surgeons and engineers in their decision on whether a developed design is suitable for the specific case. A novel method for the pre-clinical testing of custom-made knee implants is suggested, which relies on the biomechanical test and finite element analysis (FEA) of a comparable reference implant. The method comprises six steps: (1) identification of the main potential failure mechanism and its corresponding FEA quantity of interest, (2) reproduction of the biomechanical test of the reference implant via FEA, (3) identification of the maximum value of the corresponding FEA quantity of interest at the required load level, (4) definition of this value as the acceptance criterion for the FEA of the custom-made implant, (5) reproduction of the biomechanical test with the custom-made implant via FEA, (6) conclusion, whether the acceptance criterion is fulfilled or not. Two exemplary cases of custom-made knee implants were evaluated with this method. The FEA acceptance criterion derived from the reference implants was fulfilled in both custom-made implants. Subsequent biomechanical tests verified the FEA results. The suggested method allows a quantitative evaluation of the biomechanical properties of a custom-made knee implant without performing a biomechanical test with it. This represents an important contribution in the pre-clinical testing of custom-made implants in order to achieve a sustainable treatment of complex revision total knee arthroplasty patients in a timely manner.

11 April 2023 in Orthopaedic Proceedings
Verified
Journal Article
Closed access
GHG. Hettich
G. Hettich
JWJosef Benedikt Weiß
Josef Benedikt Weiß
TGT.M. Grupp
T.M. Grupp
PRE-CLINICAL EVALUATION OF CUSTOM-MADE KNEE IMPLANTS USING FINITE ELEMENT ANALYSIS