George Patrick Jenkinson

Mr. George Patrick Jenkinson

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 January 2023 in Sensors
Verified
Journal Article
Open access
PDF file
GJGeorge Patrick Jenkinson
George Patrick Jenkinson
ACAndrew Conn
Andrew Conn
ATAntonia Tzemanaki
Antonia Tzemanaki
Optimising the sensitivity of a tactile sensor to a specific range of stimuli magnitude usually compromises the sensor’s widespread usage. This paper presents a novel soft tactile sensor capable of dynamically tuning its stiffness for enhanced sensitivity across a range of applied forces, taking inspiration from the Eustachian tube in the mammalian ear. The sensor exploits an adjustable pneumatic back pressure to control the effective stiffness of its 20 mm diameter elastomer interface. An internally translocated fluid is coupled to the membrane and optically tracked to measure physical interactions at the interface. The sensor can be actuated by pneumatic pressure to dynamically adjust its stiffness. It is demonstrated to detect forces as small as 0.012 N, and to be sensitive to a difference of 0.006 N in the force range of 35 to 40 N. The sensor is demonstrated to be capable of detecting tactile cues on the surface of objects in the sub-millimetre scale. It is able to adapt its compliance to increase its ability for distinguishing between stimuli with similar stiffnesses (0.181 N/mm difference) over a large range (0.1 to 1.1 N/mm) from only a 0.6 mm deep palpation. The sensor is intended to interact comfortably with skin, and the feasibility of its use in palpating tissue in search of hard inclusions is demonstrated by locating and estimating the size of a synthetic hard node embedded 20 mm deep in a soft silicone sample. The results suggest that the sensor is a good candidate for tactile tasks involving unpredictable or unknown stimuli.

3 April 2023 in Journal of Participatory Medicine
Verified
Journal Article
Open access
GJGeorge Patrick Jenkinson
George Patrick Jenkinson
NHNatasha Houghton
Natasha Houghton
NZNejra van Zalk
Nejra van Zalk
JWJo Waller
Jo Waller
FBFernando Bello
Fernando Bello
ATAntonia Tzemanaki
Antonia Tzemanaki
Background: In the United Kingdom, women aged 50 to 70 years are invited to undergo mammography. However, 10% of invasive breast cancers occur in women aged ≤45 years, representing an unmet need for young women. Identifying a suitable screening modality for this population is challenging; mammography is insufficiently sensitive, whereas alternative diagnostic methods are invasive or costly. Robotic clinical breast examination (R-CBE)—using soft robotic technology and machine learning for fully automated clinical breast examination—is a theoretically promising screening modality with early prototypes under development. Understanding the perspectives of potential users and partnering with patients in the design process from the outset is essential for ensuring the patient-centered design and implementation of this technology. Objective: This study investigated the attitudes and perspectives of women regarding the use of soft robotics and intelligent systems in breast cancer screening. It aimed to determine whether such technology is theoretically acceptable to potential users and identify aspects of the technology and implementation system that are priorities for patients, allowing these to be integrated into technology design. Methods: This study used a mixed methods design. We conducted a 30-minute web-based survey with 155 women in the United Kingdom. The survey comprised an overview of the proposed concept followed by 5 open-ended questions and 17 closed questions. Respondents were recruited through a web-based survey linked to the Cancer Research United Kingdom patient involvement opportunities web page and distributed through research networks’ mailing lists. Qualitative data generated via the open-ended questions were analyzed using thematic analysis. Quantitative data were analyzed using 2-sample Kolmogorov-Smirnov tests, 1-tailed t tests, and Pearson coefficients. Results: Most respondents (143/155, 92.3%) indicated that they would definitely or probably use R-CBE, with 82.6% (128/155) willing to be examined for up to 15 minutes. The most popular location for R-CBE was at a primary care setting, whereas the most accepted method for receiving the results was an on-screen display (with an option to print information) immediately after the examination. Thematic analysis of free-text responses identified the following 7 themes: women perceive that R-CBE has the potential to address limitations in current screening services; R-CBE may facilitate increased user choice and autonomy; ethical motivations for supporting R-CBE development; accuracy (and users’ perceptions of accuracy) is essential; results management with clear communication is a priority for users; device usability is important; and integration with health services is key. Conclusions: There is a high potential for the acceptance of R-CBE in its target user group and a high concordance between user expectations and technological feasibility. Early patient participation in the design process allowed the authors to identify key development priorities for ensuring that this new technology meets the needs of users. Ongoing patient and public involvement at each development stage is essential.

3 December 2020
Verified
Book Chapter
Closed access
PDF file
GJGeorge Patrick Jenkinson
George Patrick Jenkinson
ACAndrew Conn
Andrew Conn
ATAntonia Tzemanaki
Antonia Tzemanaki

14 September 2022 in JMIR Preprints
Verified
Preprint
Open access
GJGeorge Patrick Jenkinson
George Patrick Jenkinson
NHNatasha Houghton
Natasha Houghton
NZNejra van Zalk
Nejra van Zalk
JWJo Waller
Jo Waller
FBFernando Bello
Fernando Bello
ATAntonia Tzemanaki
Antonia Tzemanaki
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet #Preprint #PeerReviewMe: Warning: This is a unreviewed preprint. Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn. Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period. Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author). Background: In the United Kingdom, women aged 50 to 70 years are invited to undergo mammography. However, 10% of invasive breast cancers occur in women aged ≤45 years, representing an unmet need for young women. Identifying a suitable screening modality for this population is challenging; mammography is insufficiently sensitive, whereas alternative diagnostic methods are invasive or costly. Robotic clinical breast examination (R-CBE)—using soft robotic technology and machine learning for fully automated clinical breast examination—is a theoretically promising screening modality with early prototypes under development. Understanding the perspectives of potential users and partnering with patients in the design process from the outset is essential for ensuring the patient-centered design and implementation of this technology. Objective: This study investigated the attitudes and perspectives of women regarding the use of soft robotics and intelligent systems in breast cancer screening. It aimed to determine whether such technology is theoretically acceptable to potential users and identify aspects of the technology and implementation system that are priorities for patients, allowing these to be integrated into technology design. Methods: This study used a mixed methods design. We conducted a 30-minute web-based survey with 155 women in the United Kingdom. The survey comprised an overview of the proposed concept followed by 5 open-ended questions and 17 closed questions. Respondents were recruited through a web-based survey linked to the Cancer Research United Kingdom patient involvement opportunities web page and distributed through research networks’ mailing lists. Qualitative data generated via the open-ended questions were analyzed using thematic analysis. Quantitative data were analyzed using 2-sample Kolmogorov-Smirnov tests, 1-tailed t tests, and Pearson coefficients. Results: Most respondents (143/155, 92.3%) indicated that they would definitely or probably use R-CBE, with 82.6% (128/155) willing to be examined for up to 15 minutes. The most popular location for R-CBE was at a primary care setting, whereas the most accepted method for receiving the results was an on-screen display (with an option to print information) immediately after the examination. Thematic analysis of free-text responses identified the following 7 themes: women perceive that R-CBE has the potential to address limitations in current screening services; R-CBE may facilitate increased user choice and autonomy; ethical motivations for supporting R-CBE development; accuracy (and users’ perceptions of accuracy) is essential; results management with clear communication is a priority for users; device usability is important; and integration with health services is key. Conclusions: There is a high potential for the acceptance of R-CBE in its target user group and a high concordance between user expectations and technological feasibility. Early patient participation in the design process allowed the authors to identify key development priorities for ensuring that this new technology meets the needs of users. Ongoing patient and public involvement at each development stage is essential.

7 April 2025 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
GJGeorge Patrick Jenkinson
George Patrick Jenkinson
ACAndrew Conn
Andrew Conn
ATAntonia Tzemanaki
Antonia Tzemanaki
Exploiting the high conductivity and fluidity of liquid metal, Coil-Tac is a soft transduction mechanism based on measuring change in capacitance as a flowable liquid metal core moves within a conductive helical coil. Using finite difference methods, a model is derived that estimates the response of Coil-Tac with various coil pitches to within 0.0502 pF of our experimental results in the range of 0–2.5 pF, corresponding to a lateral liquid metal movement of up to 35 mm. The Coil-Tac mechanism is demonstrated to be capable of oscillatory tactile sensing at 5 Hz and touch location estimation when coupled to a soft interface. The mechanism coupled with the interface is sensitive enough to locate the centre of the contact to within 0.23 mm, and estimate the incident angle between the axis of the dome and a flat surface to within 0.53$^{\circ }$.