Pratik Chhatbar

Dr. Pratik Chhatbar

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2018 in Brain Stimulation
Verified
Journal Article
Closed access
PCPratik Chhatbar
Pratik Chhatbar
SKSteven A. Kautz
Steven A. Kautz
ITIstvan Takacs
Istvan Takacs
NRNathan C. Rowland
Nathan C. Rowland
GRGonzalo J. Revuelta
Gonzalo J. Revuelta
WFWuwei Feng
Wuwei Feng

1 July 2021 in Journal of Stroke and Cerebrovascular Diseases
Verified
Journal Article
Closed access
BGBrian Mac Grory
Brian Mac Grory
MSMatthew Schrag
Matthew Schrag
SPSven Poli
Sven Poli
CBChantal J. Boisvert
Chantal J. Boisvert
Martin SpitzerMartin Spitzer
Martin Spitzer
WFWuwei Feng
Wuwei Feng


1 November 2017 in Brain, Behavior, and Immunity
Verified
Journal Article
Closed access
PCPratik Chhatbar
Pratik Chhatbar
MGMark S. George
Mark S. George
SKSteven A. Kautz
Steven A. Kautz
WFWuwei Feng
Wuwei Feng

1 July 2020 in Brain Stimulation
Verified
Journal Article
Open access
SSShreyansh Shah
Shreyansh Shah
PCPratik Chhatbar
Pratik Chhatbar
JFJody A. Feld
Jody A. Feld
WFWuwei Feng
Wuwei Feng

15 November 2021 in Skin Health and Disease
Verified
Journal Article
Open access
PDF file
PCPratik Chhatbar
Pratik Chhatbar
SLS. Liu
S. Liu
VRV. Ramakrishnan
V. Ramakrishnan
MGM. S. George
M. S. George
SKS. A. Kautz
S. A. Kautz
WFW. Feng
W. Feng
Background Transcranial direct current stimulation (tDCS) is reported to induce irritating skin sensations and occasional skin injuries, which limits the applied tDCS dose. Additionally, tDCS hardware safety profile prevents high current delivery when skin resistance is high. Objective To test if decreasing skin resistance can enable high-dose tDCS delivery without increasing tDCS-related skin sensations or device hardware limits. Methods We compared the effect of microdermabrasion and sonication on 2 mA direct current stimulation (DCS) through forearm skin for 2–3 min on 20 subjects. We also surveyed the subjects using a questionnaire throughout the procedure. We used a linear mixed-effects model for repeated-measures and multiple logistic regression, with adjustments for age, race, gender and visit. Results Microdermabrasion, with/out sonication, led to significant decrease in skin resistance (1.6 ± 0.1 kΩ or ∼32% decrease, p < 0.0001). The decrease with sonication alone (0.4 ± 0.1 kΩ or ∼7% decrease, p = 0.0016) was comparable to that of sham (0.3 ± 0.1 kΩ or ∼5% decrease, p = 0.0414). There was no increase in the skin–electrode interface temperature. The perceived DCS-related sensations did not differ across skin preparation procedures (p > 0.16), but microdermabrasion (when not combined with sonication) led to increased perceived sensation (p < 0.01). Conclusions Microdermabrasion (with/out sonication) resulted in reduced skin resistance without increase in perceived skin sensations with DCS. Higher current can be delivered with microdermabrasion-pre-treated skin without changing the device hardware while reducing, otherwise higher voltage required to deliver the same amount of current.