In this work, microbubble dispersed air flotation technique was applied for cadmium ions removal from wastewater aqueous solution. Experiments parameters such as pH (3, 4, 5, and 6), initial Cd(II) ions concentration (40, 80, and 120 mg/l) contact time( 2, 5, 10 , 15, and 20min), and surfactant (10, 20and 40mg/l) were studied in order to optimize the best conditions .The experimental results indicate that microbubbles were quite effective in removing cadmium ions and the anionic surfactant SDS was found to be more efficient than cationic CTAB in flotation process. 92.3% maximum removal efficiency achieved through 15min at pH 5, SDS surfactant concentration 20mg/l, flow rate250 cm3/min and at 40mg/l Cd(II) ions initial concentration. The removal efficiency of cadmium ion was predicted through 11 neurons hidden layer, with a correlation coefficient of 0.9997 between ANN outputs and the experimental data and through sensitivity analysis, pH was found to be most significant parameter (25.13 %).The kinetic flotation order for cadmium ions almost first order and the removal rate constant (k) increases with decreasing the initial metal concentration.
A cost effective, fast, and accurate technique was needed to measure the vapor composition of a binary system (ethanol-water) and also that of a liquid composition in a ternary system (acetic acid-acetol–water) in a microbubble distillation unit. Cheap TGS-series gas sensors were used for this purpose with both calibrations and measurements carried out in a specially designed chamber. A single parameter polynomial regression was fitted to the binary system, and a two parameter polynomial with an interaction term was fitted to the ternary system. The correlation coefficient, R-squared, was found to be greater than 0.99 for both systems, thus validating the implementation of this novel sensor.
29 August 2025 in Desalination and Water Treatment
A low-cost in-line ozone monitor based on the principle of ultraviolet absorption was built and tested for different ozone for concentrations up to 300 mg h-1 and flow rates up to 5 lpm using air as a feed source. A widely available T5 ultraviolet (UV) tube was used as a UV source and two UV light absorption cells were made to act as reference and measuring cells. The output of the two cells was used to calculate the ozone concentration using Beer-Lambert’s law. To correlate the output readings of the ozone monitor with those obtained using the iodometric titration method, a correction factor of 1.5117 was determined and applied. The results demonstrate a strong linear correlation ≥0.99 between estimated and measured ozone concentration values. Relative errors less than 10% were observed for ozone concentrations ranging from 400 to 5000 ppb, while a relative error up to 16% was reported for concentrations below 400 ppb. The developed monitor offers a cost-effective alternative to expensive ozone monitoring systems for standard applications, with a total construction cost under $100.