Ayumi Ohnishi

Dr. Ayumi Ohnishi

Kobe University, Kōbe, Hyōgo, Japan
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 December 2024 in Electronics
Verified
Journal Article
Open access
PDF file
NMNatsumi Matsui
Natsumi Matsui
AOAyumi Ohnishi
Ayumi Ohnishi
AUAyaka Uyama
Ayaka Uyama
TSTetsuzo Sugino
Tetsuzo Sugino
TTTsutomu Terada
Tsutomu Terada
MTMasahiko Tsukamoto
Masahiko Tsukamoto
To maintain skin moisture, we need to maintain good stratum corneum barrier function, which prevents moisture evaporation from the inside of the skin. Transepidermal water loss (TEWL), the amount of water that evaporates from the skin, indicates the state of barrier function. The barrier function of facial skin is easily damaged in daily life, and the condition of the skin becomes worse without us noticing. We should constantly monitor TEWL to prevent worsening skin conditions. In this paper, we propose a wearable device that continuously measures TEWL. We estimate TEWL using machine learning from temperature and humidity values of water evaporation from the skin and parameters that affect TEWL, such as skin surface temperature and galvanic skin response. We experimented with the prototype device in a controlled environment. We confirmed that the prototype device could estimate TEWL accurately enough to judge the skin’s condition in stationary and conversational situations. Then, we experimented to verify the environmental conditions for estimating TEWL using the prototype device. The prototype device could estimate TEWL with sufficient precision in an office without airflow. However, we could not estimate TEWL in the office with airflow and outdoor.

11 September 2022
Verified
Conference Paper
Open access
SUSoichiro Utsumi
Soichiro Utsumi
AOAyumi Ohnishi
Ayumi Ohnishi
TTTsutomu Terada
Tsutomu Terada
MTMasahiko Tsukamoto
Masahiko Tsukamoto
Insufficient blinking causes dry eyes; thus, several systems have been developed to increase the rate of blinking to alleviate dry eyes. However, forcing a user to blink may adversely affect their work because blinking obstructs their vision. In this study, we propose a system that triggers reflex blinking in users while ensuring that its timing is appropriate. Appropriate timing ensures that the induced blinking does not cause the user to miss important information or experience perceptual confusion. Consequently, it does not adversely impact the user. In this study, we attempted to determine the appropriate timing for blinking using an object tracking test, and found that the test scores were dependent on the timing. Finally, we designed a wearable system that triggers appropriately timed reflex blinking and implemented a prototype of the system.

22 March 2021
Verified
Conference Paper
Closed access
AOAyumi Ohnishi
Ayumi Ohnishi
HTHayate Tohnan
Hayate Tohnan
TTTsutomu Terada
Tsutomu Terada
MHMinoru Hattori
Minoru Hattori
HYHisaaki Yoshinaka
Hisaaki Yoshinaka
MTMasahiko Tsukamoto
Masahiko Tsukamoto
Robot-assisted laparoscopic surgery, such as the da Vinci Surgical System, has a problem in that surgeons might continue operating for a long period of time without realizing their fatigue and without proper concentration, or they might ignore their fatigue even when they notice it. We propose a method for quantitatively estimating the level fatigue by attaching wearable sensors to a doctor while using a surgical robot. In this study, several sensor configurations were tested to investigate the sensor configuration, which is easy for the surgeon to wear. In an evaluation experiment, doctors used a robotic surgery simulator for a long period of time, and the score calculated by the simulator was estimated as the fatigue level expressed by the surgeon. We discussed with doctors how the results of the fatigue estimation should be applied to the system design.

17 July 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
AOAyumi Ohnishi
Ayumi Ohnishi
RTRyosuke Takegawa
Ryosuke Takegawa
KHKazuhiko Hirata
Kazuhiko Hirata
MTMinoru Toriyama
Minoru Toriyama
TTTsutomu Terada
Tsutomu Terada
MTMasahiko Tsukamoto
Masahiko Tsukamoto
Anterior cruciate ligament (ACL) injuries are common in sports involving jumping and rapid direction changes, often occurring in non-contact situations. The risk of ACL injury is evaluated by knee flexion and valgus angles; a small knee flexion angle combined with a large valgus angle increases the risk. Monitoring these angles during activities can help athletes recognize their ACL injury risk and adjust their movements. Traditional 3D motion analysis, used for measuring knee angles, is costly and impractical for daily practice. This study proposes a knee supporter with stretch sensors to estimate knee flexion and valgus angles in practice settings, evaluating ACL injury risk and notifying athletes of high-risk movements. The proposed device wirelessly transmits data from three stretch sensors placed on the device to a PC and uses machine learning to estimate the knee angles. The results of the evaluation experiments, conducted with data from five healthy male and female participants in their twenties, indicate that the estimation accuracy for the knee flexion angle, achieved by a model trained using a Random Forest Regressor (RFR) with data from individuals other than the target user, resulted in a Mean Absolute Error (MAE) of 8.86 degrees. For the knee valgus angle, a model trained with the user’s own data using the RFR achieved a MAE of 0.81 degrees.

22 November 2023
Verified
Book Chapter
Closed access
PDF file
AOAyumi Ohnishi
Ayumi Ohnishi
KKKota Kirinoe
Kota Kirinoe
TTTsutomu Terada
Tsutomu Terada
MTMasahiko Tsukamoto
Masahiko Tsukamoto

10 March 2025 in Sci
Verified
Journal Article
Open access
PDF file
KWKai Washino
Kai Washino
AOAyumi Ohnishi
Ayumi Ohnishi
TTTsutomu Terada
Tsutomu Terada
MTMasahiko Tsukamoto
Masahiko Tsukamoto
Saliva is an important fluid related to the maintenance of oral and systemic health, and a decrease in saliva volume causes various adverse effects. Saliva volume should be increased to avoid the adverse effects caused by decreased saliva volume. One method to increase saliva volume is to use a wearable device daily. Wearable devices that increase saliva volume in daily life should have the following features: easy to put on and take off, automatic movement, and no need to put the device in the mouth. To the authors’ knowledge, no such device exists. Therefore, this study aims to design a wearable device that can increase saliva volume in daily life using stimulus. Several previous studies have shown that lemon odor, massage of the lower part of the jaw, and warming of the lower jaw can increase saliva volume. However, it is not known whether these three stimuli can increase saliva volume quickly and under any situation. Therefore, in this paper, we investigate suitable stimuli for increasing saliva volume under situations that may change the effect of the stimuli for the construction of a wearable device. First, we implemented a mask-type experimental wearable device that can provide odor, pressure, and thermal stimulus. Next, a questionnaire survey was administered to confirm the situations under which saliva volume decreases. The results of the questionnaire showed that saliva volume decreased after conversations, after exercise, and upon waking up. Therefore, we investigated which of the three stimuli increased saliva volume quickly under these three situations and the usual situation. The results show that an odor stimulus significantly increased saliva volume in all situations compared to other stimuli. Based on the experimental results, we propose an eyeglass-shaped device that can provide an odor stimulus. The odor stimulus of the proposed device also significantly increased saliva volume.