With a Euler–Euler (E2P) approach, a mathematical model for predicting the pointwise hydrodynamic behavior of a spouted bed was implemented though computational fluid dynamics (CFD) techniques. The model considered a bed elasticity approach in order to reduce the number of required sub-models to provide closure for the solids stress strain-tensor. However, no modulus of elasticity sub-model for a bed elasticity approach has been developed for spouted beds, and thus, large deviations in the predictions are obtained with common sub-models reported in literature. To overcome such a limitation, a new modulus of elasticity based on a sensitivity analysis was developed and implemented on the E2P model. The model predictions were locally validated against experimental measurements obtained in previous studies. The experimental studies were conducted using our in-house developed advanced γ-ray computed tomography (CT) technique, which allows to obtain the cross-sectional time-averaged solids holdup distribution. When comparing the model predictions against the experimental measurements, a high predictive quality for the radial solids holdup distribution in the spout and annulus regions is observed. The model predicts most of the experimental measurements for different particle diameters, different static bed heights, and different inlet velocities with deviations under 15%, with average absolute relative errors (AARE) between 5.75% and 7.26%, and mean squared deviations (MSD) between 0.11% and 0.24%
A new methodology for implementing radioactive particle tracking (RPT) in bubble columns with intense vertical rod internals was developed and implemented to investigate the effect of dense internals on hydrodynamics. The methodology utilizes a hybrid of Monte Carlo N-Particle (MCNP) simulation and an automated RPT calibration device to generate a large number of calibration points for accurate reconstruction of the instantaneous positions of radioactive particles using a similarity algorithm. Measurements were conducted in a 6-inch (15.24 cm) Plexiglas column using an air–water system at a superficial gas velocity of 40 cm/s. Vertical Plexiglas rods 0.5 in (1.27 cm) in diameter were used to cover ~25% of the total cross-sectional area of the column to represent the effect of a heat-exchanging tube in industrial Fisher–Tropsch synthesis. The results showed that the internals increased liquid velocity near the center of the column by more than 30%, resulting in enhanced liquid circulation and frequency of liquid eddy movement. In addition, turbulence parameters decreased noticeably when using vertical internals in the bubble column due to a reduction in velocity fluctuations. Reliable data can help validate computational fluid dynamics (CFD) models to predict hydrodynamic parameters at other various conditions.