With the rapid development of microgrid and large-scale grid-connected operation, the detection and location of short-circuit faults in microgrid has become a bottleneck. In this paper, a simulation model of short-circuit fault in low-voltage AC microgrid is built on PSCAD/EMTDC. The characteristics of current wavelet energy spectrum under various short-circuit fault states are studied and the early detection of faults is realized. Based on the relationship between the first peak value of fault current wavelet energy spectrum and the location of short-circuit points, a method for early detection and area location of short-circuit faults in microgrid is proposed. The simulation and experimental results show that this method can detect and locate the short-circuit fault area of microgrid quickly and accurately.
Micro grid fault of rapid detection and removal is the key to ensure its reliability. With the access of many distributed generations (DG) to the system, the characteristics of short-circuit faults of microgrids in grid-connected and islanded modes have changed, and the traditional protection methods can no longer be applied to both operating modes of microgrids simultaneously. Due to the advantages of wavelet energy spectrum in the identification of the mutation characteristics of the weak signal as well as that of neural network in the location accuracy, this paper proposes a short circuit fault detection and protection method in AC microgrids. The method takes the current at the detection point as the object of analysis, uses the wavelet energy spectrum transform to analyze the current waveforms under normal and fault operation states, and extracts the fault characteristic quantities. At the same time, considering the effect of transition resistance, a generalized fault area identification model for both grid-connected and islanded modes is established by using a neural network algorithm. Simulation and experimental results show that this method can realize accurate judgment and area location of short-circuit faults in different modes, different DG capacities, different fault types and different fault regions.
16 April 2025 in IEEE Transactions on Instrumentation and Measurement
Arc faults are a major cause of electrical fires. Due to the diversity of load types, existing arc fault detection (AFD) methods struggle to cover all load types, making the development of a universal detection method a significant challenge. This paper presents a specially designed dual-winding sensor which can realize self-couple on the secondary side to address the issues existed for self-couple on the primary-side. The arc fault signal characteristics of both categories, as specified in IEC 62606 and GB 14287.4, are collected and analyzed. By suppressing the low-frequency signal and amplifying the high-frequency signal under resonant conditions, a universal arc fault detection device is designed and experimentally validated. The device is unaffected by the position of the tested wire. Results indicate that the presented method demonstrates strong universality and reduces the likelihood of false positives when detecting arc faults.