Manuel Manrique

Prof. Dr. Manuel Manrique


Research Focus & Metrics

Academic Career Length

34Years (1993-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2005 in Acta Oto-Laryngologica
Verified
Journal Article
Closed access
CJChris James
Chris James
KAKlaus Albegger
Klaus Albegger
RBRolf Battmer
Rolf Battmer
SBSandro Burdo
Sandro Burdo
NDNaima Deggouj
Naima Deggouj
BFBernard Fraysse
Bernard Fraysse
Conclusions Hearing may be conserved in adults after implantation with the Nucleus Contour Advance perimodiolar electrode array. The degree of hearing preservation and the maximum insertion depth of the electrode array can vary considerably despite a defined surgical protocol. Residual hearing combined with electrical stimulation in the same ear can provide additional benefits even for conventional candidates for cochlear implantation. Objectives We present preliminary results from a prospective multicentre study investigating the conservation of residual hearing after implantation with a standard-length Nucleus Contour Advance perimodiolar electrode array and the benefits of combined electrical and acoustic stimulation. Material and methods The subjects were 12 adult candidates for cochlear implantation recruited according to national selection criteria. A “soft” surgery protocol was defined, as follows: 1–1.2-mm cochleostomy hole anterior and inferior to the round window; Nucleus Contour Advance electrode array inserted using the “Advance-off-stylet” technique; and insertion depth controlled by means of three square marker ribs left outside the cochleostomy hole. These procedures had been shown to reduce insertion forces in temporal bone preparations. Variations in surgical techniques were monitored using a questionnaire. Pure-tone thresholds were measured pre- and postoperatively. Patients who still retained thresholds <90 dB HL for frequencies up to 500 Hz were re-fitted with an in-the-ear (ITE) hearing aid. Word recognition was tested in quiet and sentence perception in noise for the cochlear implant alone and in combination with an ipsilateral hearing aid. Results Hearing threshold level data were available for 12 patients recruited from 6 of the centres. Median increases in hearing threshold levels were 23, 27 and 33 dB for the frequencies 125, 250 and 500 Hz, respectively. These median increases include the data for two patients who had total loss of residual hearing due to difficulties encountered during surgery. “Cochlear view” X-ray images indicated that the depth of insertion varied between 300 and 430°, despite modest variations in the length of the electrode inserted (17–19 mm). The insertion angle had some influence on the preservation of residual hearing at frequencies of 250–500 Hz. Six of the 12 patients retained sufficient hearing for effective use of an ipsilateral ITE hearing aid (≤80 dB HL at 125 and 250 Hz; ≤90 dB HL at 500 Hz). Word recognition scores in quiet were improved from 10% to 30% with the cochlear implant plus ipsilateral hearing aid in 3 patients who had at least 3 months postoperative experience. Signal:noise ratio thresholds for sentence recognition were improved by up to 3 dB. Patients reported that they experienced greatly improved sound quality and preferred to use the two devices together.

1 August 2006 in Otology & Neurotology
Verified
Journal Article
Closed access
BFBernard Fraysse
Bernard Fraysse
ÁMÁngel Ramos Macías
Ángel Ramos Macías
OSOlivier Sterkers
Olivier Sterkers
SBSandro Burdo
Sandro Burdo
RRRichard Ramsden
Richard Ramsden
CJChris James
Chris James
To assess the conservation of residual hearing in recipients of the Nucleus 24 Contour Advance cochlear implant (CI) and the benefits of combined electrical and acoustic stimulation. Prospective multicenter study. CI clinics in Western Europe. Adult candidates for conventional cochlear implantation with a minimum preoperative word recognition score of 10% in the ear to be implanted. "Soft-surgery" protocol, including a 1- to 1.2-mm anterior and inferior cochleostomy hole with the electrode array, inserted 17 mm using the "advance-off-stylet" technique. Patients with postoperative pure-tone hearing threshold levels (HTLs) of 80 dB hearing loss or less at 125 and 250 Hz and 90 dB hearing loss or less at 500 Hz were refitted with an in-the-ear hearing aid for combined ipsilateral electrical and acoustic (El-Ac) stimulation. A questionnaire to collect information regarding surgery. Pure-tone HTLs measured at intervals. Word recognition tested in quiet and sentence recognition tested in noise at 10 and 5 dB signal-to-noise ratio (SNR). HEARING CONSERVATION RESULTS: HTL data were available for 27 patients. HTLs were conserved within 20 dB of preoperative levels for 33, 26, and 19% of patients for 125, 250, and 500 Hz, respectively. However, the recommended soft-surgery protocol was strictly followed in only 12 of 27 patients. For these 12 patients, hearing thresholds were conserved within 20 dB for 50, 50, and 33% of patients. Median threshold increases were 40 dB (range, 250-500 Hz) for the whole group and 23 dB for the strict surgery group. Ten patients retained sufficient HTLs to enter the El-Ac user group. SPEECH RECOGNITION RESULTS: Group mean recognition scores for nine El-Ac users for words presented at 65 dB sound pressure level were 45% for CI alone and 55% for CI + ipsilateral hearing aid (p < 0.05, paired t). For sentences presented in noise at 5 dB SNR, mean word scores were 46% CI alone and 56% CI + ipsilateral hearing aid (p < 0.01, paired t). Hearing was conserved for conventional candidates for cochlear implantation where the recommended soft-surgery protocol was strictly adhered. Combined ipsilateral electrical and acoustic stimulation provided considerable benefits for speech recognition in noise, equivalent to between 3 and 5 dB SNR, compared with CI alone.

1 November 2005 in European Journal of Neuroscience
Verified
Journal Article
Closed access
PDF file
MAM. Alegre
M. Alegre
FAF. Alonso‐Frech
F. Alonso‐Frech
MRMaría Cruz Rodríguez-Oroz
María Cruz Rodríguez-Oroz
JGJ. Guridi
J. Guridi
IZI. Zamarbide
I. Zamarbide
JAJ. Artieda
J. Artieda

2 September 2013 in International Journal of Audiology
Verified
Journal Article
Closed access
TLThomas Lenarz
Thomas Lenarz
CJChris James
Chris James
DCDomenico Cuda
Domenico Cuda
AOAlec Fitzgerald O’cOnnor
Alec Fitzgerald O’cOnnor
BFBruno Frachet
Bruno Frachet
AUAlain Uziel
Alain Uziel
To investigate the preservation of residual hearing in subjects who received the Nucleus Hybrid L24 cochlear implant. To investigate the performance benefits up to one year post-implantation in terms of speech recognition, sound quality, and quality of life. Prospective, with sequential enrolment and within-subject comparisons. Post-operative performance using a Freedom Hybrid sound processor was compared with that of pre-operative hearing aids. Sixty-six adult hearing-impaired subjects with bilateral severe-to-profound high frequency hearing loss. Group median increase in air-conduction thresholds in the implanted ear for test frequencies 125-1000 Hz was < 15 dB across the population; both immediately and one year post-operatively. Eighty-eight percent of subjects used the Hybrid processor at one year post-op. Sixty-five percent of subjects had significant gain in speech recognition in quiet, and 73% in noise (≥ 20 percentage points/2 dB SNR). Mean SSQ subscale scores were significantly improved (+ 1.2, + 1.3, + 1.8 points, p < 0.001), as was mean HUI3 score (+ 0.117, p < 0.01). Combining residual hearing with CI gave 22-26 %age points mean benefit in speech recognition scores over CI alone (p < 0.01). Useful residual hearing was conserved in 88% of subjects. Speech perception was significantly improved over preoperative hearing aids, as was sound quality and quality of life.

1 June 2002 in Ear & Hearing
Verified
Journal Article
Closed access
BNBarry Nevison
Barry Nevison
RLRoland Laszig
Roland Laszig
WSWolf-Peter Sollmann
Wolf-Peter Sollmann
TLThomas Lenarz
Thomas Lenarz
OSOlivier Sterkers
Olivier Sterkers
EWErnst von Wallenberg
Ernst von Wallenberg
This study was designed to investigate the perceptual benefits and potential risks of implanting the Nucleus® multichannel auditory brainstem implant. Between September 1992 and October 1997 a total of 27 subjects received a Nucleus 20- or 21-channel Auditory Brainstem Implant (ABI). All subjects involved in the trial had bilateral acoustic tumour as a result of neurofibromatosis type 2 (NF2) resulting in complete dysfunction of the VIIIth nerve. The study used each subject as their own control without a preoperative baseline because residual hearing, if existing, was destroyed at surgery by tumour removal. A battery of speech tests was conducted to evaluate each patient’s performance and communication abilities. Tests were conducted, where possible, in the auditory-only, visual-only, and auditory-visual conditions at 3 days postoperatively (baseline), at 3-mo intervals for the first year and every 12 mo thereafter. A subjective performance questionnaire was administered together with an extensive neurological examination at each test interval. 27 subjects involved in this trial were successfully implanted with a Nucleus ABI. One subject died 2 days postoperatively due to a lung embolism unrelated to the device. Twenty-six subjects underwent device activation and all but one patient received auditory sensation at initial stimulation (96.2%). On average 8.6 (±4.2) of the available 21 electrodes were used in the patients’ MAPs. Performance evaluation measures showed that the majority of users had access to auditory information such as environmental sound awareness together with stress and rhythm cues in speech that assist with lipreading. Although most subjects did not achieve any functional auditory-alone, open-set speech understanding, two subjects from this series (7.4%) did receive sufficient benefit to be able to use the ABI in conversation without lipreading. Although the medical risks and surgical complexity associated with ABI device implantation are far greater than those for a cochlear implant, the clinical results from this trial show that the Nucleus multichannel ABI is capable of providing a significant patient benefit over risk ratio for subjects suffering loss of hearing due to bilateral retrocochlear lesions.

1 August 2004 in The Laryngoscope
Verified
Journal Article
Closed access
PDF file
MMManuel Manrique
Manuel Manrique
FCFrancisco Javier Cervera‐Paz
Francisco Javier Cervera‐Paz
AHAlicia Huarte
Alicia Huarte
MMMaite Molina
Maite Molina