As a basic building block in power systems, the three-phase voltage-source inverter (VSI) connects the distributed energy to the grid. For the inductor-capacitor-inductor (LCL)-filter three-phase VSI, according to different current sampling position and different reference frame, there mainly exist four control schemes. Different control schemes present different impedance characteristics in their corresponding determined frequency range. To analyze the existing resonance phenomena due to the variation of grid impedances, the sequence impedance models of LCL-type grid-connected three-phase inverters under different control schemes are presented using the harmonic linearization method. The impedance-based stability analysis approach is then applied to compare the relative stability issues due to the impedance differences at some frequencies and to choose the best control scheme and the better controller parameters regulating method for the LCL-type three-phase VSI. The simulation and experiments both validate the resonance analysis results.
This paper presents a small signal stability analysis to assess the stability issues facing PV (photovoltaic) inverters connected to a weak grid. It is revealed that the cause of the transient instabilities, either high-frequency or low-frequency oscillations, is dominated by the outer control loops and the grid strength. However, most challenging oscillations are low-frequency oscillations induced by coupling interaction between the outer loop controller and PLL (Phase-Locked Loop) when the inverter is connected to a weak grid. Therefore, the paper proposes a low-frequency damping methodology in order to enhance the high system integration, while maintaining the stability of the system. The control method uses a DC link voltage error to modulate the reference reactive current. The proposed control reduces the low-frequency coupling between the DVC (DC link voltage controller), AVC (AC voltage controller) and PLL (Phase-locked loop). According to this study’s results, the performance capability of the grid-connected PV inverter is improved and flexibility in the outer loop controller design is enhanced. The control strategy proposed in this paper is tested using the PLECS simulation software (Plexim GmbH, Zurich Switzerland) and the results are compared with the conventional method.
This paper presents a robust multi-input multi-output (MIMO) state-feedback control scheme for a photovoltaic (PV) inverter connected to a weak grid. For a weak grid, the point of common coupling (PCC) voltage is very sensitive to the power disturbances and it is dynamically coupled to the PLL dynamics. So far, most of the control methods do not take into accounts these couplings. Therefore, in this paper, the MIMO controller was designed taking into account the dynamics of the phase-locked loop (PLL) and coupling effects between PCC voltage and the active power to enhance the system’s robustness. As result, the robust performance of the PV inverter interfaced to a weak grid was yielded. In addition, the sensitivity of the system to PLL was eliminated, allowing the use of larger PLL bandwidth even in a very weak grid. Based on the eigenvalues analysis method, a comparative study between the proposed control method and the conventional vector control method was performed. The proposed method is verified with simulations in PLECS and real-time simulations in the RT Box. The results show that the proposed MIMO control method preserves the system stability robustness against any change of grid strength, generated power and PLL bandwidth.