Mohammadreza Forouzeshfard

Dr. Mohammadreza Forouzeshfard

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2021 in Journal of Luminescence
Verified
Journal Article
Closed access
MFMohammadreza Forouzeshfard
Mohammadreza Forouzeshfard
SGSana Ghafari
Sana Ghafari
ZVZohreh Vafapour
Zohreh Vafapour

25 November 2019 in IEEE Sensors Journal
Verified
Journal Article
Closed access
SGSana Ghafari
Sana Ghafari
MFMohammadreza Forouzeshfard
Mohammadreza Forouzeshfard
ZVZohreh Vafapour
Zohreh Vafapour
Plasmonic induced transparency as an interesting physics behind many novel plasmonic devices is used to design a nano structure composed of graphene and Indium Antimonide (InSb). Due to temperature dependent of graphene and InSb permittivity, the structure is a good candidate for temperature sensor. The sensitivity of the proposed thermal sensor is optimized and the best value for sensitivity is obtained 160(nm/k). The switch application of the proposed structure is also analyzed and a switch with modulation depth of 98% and modulation efficiency of 82% is proposed which has very good values compare to other THz switch reported in literature.

11 October 2022 in IEEE Transactions on Nanotechnology
Verified
Journal Article
Closed access
AHAbbas Hamouleh-Alipour
Abbas Hamouleh-Alipour
MFMohammadreza Forouzeshfard
Mohammadreza Forouzeshfard
RBRasool Baghbani
Rasool Baghbani
ZVZohreh Vafapour
Zohreh Vafapour
Erratic in concentration of the blood hemoglobin (Hb) is pernicious and common disease in many humans worldwide. The establishment of Hb measurement led to finding bio-optics mechanisms for tunable and high sensitivity dual-band plasmonic metasurface (PM) configuration that studied for Hb concentration detection of blood and formed by a semiconductor integrated with metal and dielectric layers. However, finding particularly useful mechanisms without surgery is a safe method with several potentials in biomedical applications. In this paper, a biosensor based on surface plasmon resonances (SPRs) that is a label-free detection method is proposed to measure Hb concentration of blood. The presented sensing method is susceptible to being a dual-bands metasurface perfect absorber at room temperature to adjust the optical properties of the integrated semiconductor plasmonic structure. The modeling and numerical performance have been fulfilled based on the finite element method (FEM) using an electromagnetic field simulation software (CST). Also, to validate the numerical results, the transfer matrix method (TMM) was introduced as an analytical model. The analytical and numerical results show a good agreement. Results indicate maximum sensitivity, figure of merit (FoM), and quality factor ( Q ) as 315 nm/RIU, 398.8, and 1407.6, respectively. By controlling and harnessing the light-matter interaction in near-infrared (NIR) region, we obtained the giant electric field intensity enhancement (EFIE) as 5000 and the maximum absorption close to 1 in the first resonance peak of λ 1 = 1.126 µm which is the best track of optical operation in NIR regime. By adding samples to the biosensor, different Hb concentrations of 0 g/L to 260 g/L have been detected from 1.11 µm to 1.17 µm. Furthermore, the proposed optical metasurface design can be utilized as a biosensor to measure the different content of Hb concentration in whole blood on a g/L scale, making it one of the best candidates for the future optical biosensors for biomedical applications.

10 October 2016 in Plasmonics
Verified
Journal Article
Closed access
PDF file
ZVZohreh Vafapour
Zohreh Vafapour
MFMohammadreza Forouzeshfard
Mohammadreza Forouzeshfard

1 December 2018 in Optics & Laser Technology
Verified
Journal Article
Closed access
EMEbrahim Moghbeli
Ebrahim Moghbeli
HAHassan Ranjbar Askari
Hassan Ranjbar Askari
MFMohammadreza Forouzeshfard
Mohammadreza Forouzeshfard