Ahmed Yasser Abdelmejeed

Mr. Ahmed Yasser Abdelmejeed

Landscape ecology and Landscape planning, Institute of spatial planning , TU Dortmund University,, Dortmund, North Rhine-Westphalia, Germany
orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 December 2023 in Land
Verified
Journal Article
Open access
PDF file
Ahmed Yasser AbdelmejeedAhmed Yasser Abdelmejeed
Ahmed Yasser Abdelmejeed
DGDietwald Gruehn
Dietwald Gruehn
This research aims to optimize the use of trees to enhance microclimate conditions, which has become necessary because of climate change and its impacts, especially for cities suffering from extreme heat stress, such as Cairo. It considers elements of urban morphology, such as the aspect ratio and orientation of canyons, which play an important role in changing microclimate conditions. It also considers both sides of each canyon because the urban shading is based on the orientation and the aspect ratio, which can provide good shade on one side of the canyon but leave the other side exposed to direct and indirect radiation, to ensure a complete assessment of how the use of trees can be optimized. As Cairo city is very large and has a variety of urban morphologies, a total of 144 theoretical cases have been tested for Cairo city using ENVI-met to cover the majority of the urban cases within the city (Stage 1). Then, the same tree scenarios used in the theoretical study are applied to an existing urban area in downtown Cairo with many urban morphology varieties to validate the results of the theoretical study (Stage 2). After testing all cases in both stages, it became very clear that the addition of trees cannot be the same for the different aspect ratios, orientations, and sides of the different canyons. For example, eastern roads should have more trees than other orientations for all aspect ratios, but the required number of trees is greater for the northern side than the southern side, as the southern side is partially shaded for a few hours of the day by buildings in moderate and deep canyons. Northern streets require a very limited number of trees, even in shallow canyons, on both sides. The correlation between the number of trees on each side for the different orientations and aspect ratios shows a strong negative relationship, but the correlation values change between the different sides and orientations. The results of applying trees to an existing urban area show almost the same results as the theoretical study’s results, with very slight differences occurring because of the irregularity of the existing study area. This proves that when adding trees, not only the aspect ratio and orientation but also the side of each canyon should be considered to ensure that pedestrians, in all cases, have better microclimate conditions and that the use of trees is optimized.

15 April 2024 in Discover Sustainability
Verified
Journal Article
Open access
PDF file
Ahmed Yasser AbdelmejeedAhmed Yasser Abdelmejeed
Ahmed Yasser Abdelmejeed
DGDietwald Gruehn
Dietwald Gruehn
This study aims to develop an efficient urban tree strategy (UTS) to enhance the microclimate conditions of cities that suffer from heat stress and strong solar radiation, such as the metropolitan area of Greater Cairo. Cairo recently lost its limited greenery to enhance traffic. The proposed UTS aims to achieve a balance between enhancing microclimate conditions and considering the city’s water scarcity. It seeks to consider all strategic factors suitable for local conditions, including the selection of tree species (Step 1), the utilization of new technologies for irrigation (Step 2), and the optimization of the usage of an efficient number of trees (Step 3). When applying the strategy’s recommendations to a study area within Cairo’s downtown center and when testing different tree coverage percentages within urban canyons of various aspect ratios and orientations using ENVI-met, the microclimate conditions are significantly enhanced in certain streets during summertime compared to wintertime. Applying the UTS not only enhances thermal comfort but also helps to create a better comfort zone during certain hours. In one street, for example, there are average physiological equivalent temperature (PET) reductions of − 5.18° and − 6.36° at 16:00 and 17:00, respectively, which also changes the thermal comfort zone from extreme heat stress to very heat stress. The results show a strong positive correlation between thermal comfort enhancement and a reduction in the total mean radiant temperature (TMRT), verifying that shading plays a primary role in enhancing the microclimate conditions of urban canyons. Applying the UTS to the study area significantly enhances the microclimate conditions. Furthermore, through the implementation of irrigation technologies that are part of the UTS, water demand is reduced to only 15% when trees with larger canopies are used. Additionally, when the tree coverage percentage reaches 35 to 50% in some streets, it results in a significant enhancement in the PET.

14 September 2024 in Land
Verified
Journal Article
Open access
PDF file
Ahmed Yasser AbdelmejeedAhmed Yasser Abdelmejeed
Ahmed Yasser Abdelmejeed
DGDietwald Gruehn
Dietwald Gruehn
Considering the impacts of climate change on the goal of obtaining sustainable and healthier cities, this research aimed to analyze and assess the impact of different urban forms with different trees densities on the dynamic physiological equivalent temperature (DPET) for pedestrians while walking further than the average walking distance (750 m) using ENVI-met. This study included five different areas within Greater Cairo, which is suffering from extreme heat stress. The selected study areas had lots of urban variety in terms of the canyons’ aspect ratios, orientations, urban form, green areas, mixed uses, and tree densities. Two tree scenarios were analyzed: the current tree density situation and a scenario where the tree density of each study area was increased to its capacity. The results proved that the DPET had different values than the steady physiological equivalent temperature (SPET) at each point within the walking routes. However, the DPET was closely related to changes in the SPET. Keeping the SPET lower or higher for a long time reduced or increased the DPET, and frequent changes (up and down) in the SPET kept the DPET stable. Changes between DPET values were driven more by the microclimate conditions of a space or canyon than the conditions of the overall area, and controlling the microclimate conditions of a whole urban canyon controlled the DPET. Changes in the DPET could reach as high as 10 °C between different walking routes, and increasing the tree density could help lower the DPET by as much as 6 °C in some cases.