Loren L. Looger

Dr. Loren L. Looger


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 July 2013 in Nature
Verified
Journal Article
Open access
PDF file
TCTsai-Wen Chen
Tsai-Wen Chen
TWTrevor J. Wardill
Trevor J. Wardill
YSYi Sun
Yi Sun
SPStefan R. Pulver
Stefan R. Pulver
SRSabine L. Renninger
Sabine L. Renninger
DKDouglas S. Kim
Douglas S. Kim
Fluorescent calcium sensors are widely used to image neural activity. Using structure-based mutagenesis and neuron-based screening, we developed a family of ultrasensitive protein calcium sensors (GCaMP6) that outperformed other sensors in cultured neurons and in zebrafish, flies and mice in vivo. In layer 2/3 pyramidal neurons of the mouse visual cortex, GCaMP6 reliably detected single action potentials in neuronal somata and orientation-tuned synaptic calcium transients in individual dendritic spines. The orientation tuning of structurally persistent spines was largely stable over timescales of weeks. Orientation tuning averaged across spine populations predicted the tuning of their parent cell. Although the somata of GABAergic neurons showed little orientation tuning, their dendrites included highly tuned dendritic segments (5–40-µm long). GCaMP6 sensors thus provide new windows into the organization and dynamics of neural circuits over multiple spatial and temporal scales.

8 November 2009 in Nature Methods
Verified
Journal Article
Open access
PDF file
LTLin Tian
Lin Tian
SHS Andrew Hires
S Andrew Hires
TMTianyi Mao
Tianyi Mao
DHDaniel Huber
Daniel Huber
MCM Eugenia Chiappe
M Eugenia Chiappe
LLLoren L. Looger
Loren L. Looger
An improved version of the GCaMP genetically encoded calcium indicator, called GCaMP3, has higher calcium affinity and increased baseline fluorescence, dynamic range and stability. GCaMP3 performs better than existing genetically encoded calcium indicators in several assays and organisms, including in vivo imaging of neuronal signaling in worms, flies and mice. Genetically encoded calcium indicators (GECIs) can be used to image activity in defined neuronal populations. However, current GECIs produce inferior signals compared to synthetic indicators and recording electrodes, precluding detection of low firing rates. We developed a single-wavelength GCaMP2-based GECI (GCaMP3), with increased baseline fluorescence (3-fold), increased dynamic range (3-fold) and higher affinity for calcium (1.3-fold). We detected GCaMP3 fluorescence changes triggered by single action potentials in pyramidal cell dendrites, with signal-to-noise ratio and photostability substantially better than those of GCaMP2, D3cpVenus and TN-XXL. In Caenorhabditis elegans chemosensory neurons and the Drosophila melanogaster antennal lobe, sensory stimulation–evoked fluorescence responses were significantly enhanced with GCaMP3 (4–6-fold). In somatosensory and motor cortical neurons in the intact mouse, GCaMP3 detected calcium transients with amplitudes linearly dependent on action potential number. Long-term imaging in the motor cortex of behaving mice revealed large fluorescence changes in imaged neurons over months.

3 October 2012 in The Journal of Neuroscience
Verified
Journal Article
Open access
PDF file
JAJasper Akerboom
Jasper Akerboom
TCTsai-Wen Chen
Tsai-Wen Chen
TWTrevor J. Wardill
Trevor J. Wardill
LTLin Tian
Lin Tian
JMJonathan S. Marvin
Jonathan S. Marvin
LLLoren L. Looger
Loren L. Looger
Genetically encoded calcium indicators (GECIs) are powerful tools for systems neuroscience. Recent efforts in protein engineering have significantly increased the performance of GECIs. The state-of-the art single-wavelength GECI, GCaMP3, has been deployed in a number of model organisms and can reliably detect three or more action potentials in short bursts in several systemsin vivo. Through protein structure determination, targeted mutagenesis, high-throughput screening, and a battery ofin vitroassays, we have increased the dynamic range of GCaMP3 by severalfold, creating a family of “GCaMP5” sensors. We tested GCaMP5s in several systems: cultured neurons and astrocytes, mouse retina, andin vivoinCaenorhabditischemosensory neurons,Drosophilalarval neuromuscular junction and adult antennal lobe, zebrafish retina and tectum, and mouse visual cortex. Signal-to-noise ratio was improved by at least 2- to 3-fold. In the visual cortex, two GCaMP5 variants detected twice as many visual stimulus-responsive cells as GCaMP3. By combiningin vivoimaging with electrophysiology we show that GCaMP5 fluorescence provides a more reliable measure of neuronal activity than its predecessor GCaMP3. GCaMP5 allows more sensitive detection of neural activityin vivoand may find widespread applications for cellular imaging in general.

17 June 2019 in Nature Methods
Verified
Journal Article
Closed access
PDF file
HDHod Dana
Hod Dana
YSYi Sun
Yi Sun
BMBoaz Mohar
Boaz Mohar
BHBrad K. Hulse
Brad K. Hulse
AKAaron M. Kerlin
Aaron M. Kerlin
DKDouglas S. Kim
Douglas S. Kim

13 January 2013 in Nature Methods
Verified
Journal Article
Open access
PDF file
JMJonathan S Marvin
Jonathan S Marvin
BBBart G Borghuis
Bart G Borghuis
LTLin Tian
Lin Tian
JCJoseph Cichon
Joseph Cichon
MHMark T Harnett
Mark T Harnett
LLLoren L. Looger
Loren L. Looger
A single-wavelength genetically encoded sensor of extracellular glutamate is reported. The sensor—iGluSnFR—is bright and photostable under both one- and two-photon illumination and is shown to work for in vivo imaging in worms, zebrafish and mice. We describe an intensity-based glutamate-sensing fluorescent reporter (iGluSnFR) with signal-to-noise ratio and kinetics appropriate for in vivo imaging. We engineered iGluSnFR in vitro to maximize its fluorescence change, and we validated its utility for visualizing glutamate release by neurons and astrocytes in increasingly intact neurological systems. In hippocampal culture, iGluSnFR detected single field stimulus–evoked glutamate release events. In pyramidal neurons in acute brain slices, glutamate uncaging at single spines showed that iGluSnFR responds robustly and specifically to glutamate in situ, and responses correlate with voltage changes. In mouse retina, iGluSnFR-expressing neurons showed intact light-evoked excitatory currents, and the sensor revealed tonic glutamate signaling in response to light stimuli. In worms, glutamate signals preceded and predicted postsynaptic calcium transients. In zebrafish, iGluSnFR revealed spatial organization of direction-selective synaptic activity in the optic tectum. Finally, in mouse forelimb motor cortex, iGluSnFR expression in layer V pyramidal neurons revealed task-dependent single-spine activity during running.

15 March 2023 in Nature
Verified
Journal Article
Open access
PDF file
YZYan Zhang
Yan Zhang
MRMárton Rózsa
Márton Rózsa
YLYajie Liang
Yajie Liang
DBDaniel Bushey
Daniel Bushey
ZWZiqiang Wei
Ziqiang Wei
LLLoren L. Looger
Loren L. Looger
Calcium imaging with protein-based indicators1,2 is widely used to follow neural activity in intact nervous systems, but current protein sensors report neural activity at timescales much slower than electrical signalling and are limited by trade-offs between sensitivity and kinetics. Here we used large-scale screening and structure-guided mutagenesis to develop and optimize several fast and sensitive GCaMP-type indicators3–8. The resulting ‘jGCaMP8’ sensors, based on the calcium-binding protein calmodulin and a fragment of endothelial nitric oxide synthase, have ultra-fast kinetics (half-rise times of 2 ms) and the highest sensitivity for neural activity reported for a protein-based calcium sensor. jGCaMP8 sensors will allow tracking of large populations of neurons on timescales relevant to neural computation.