Sunil Kumar

Dr. Sunil Kumar


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 February 2023 in Revista de la Real Academia de Ciencias Exactas, Fisicas y Naturales. Serie A. Matematicas
Verified
Journal Article
Closed access
PDF file
SSSumit Saini
Sumit Saini
PDPratibhamoy Das
Pratibhamoy Das
SKSunil Kumar
Sunil Kumar

22 September 2017 in Numerical Methods for Partial Differential Equations
Verified
Journal Article
Closed access
PDF file
VGVikas Gupta
Vikas Gupta
MKMukesh Kumar
Mukesh Kumar
SKSunil Kumar
Sunil Kumar


1 March 2018 in Numerical Methods for Partial Differential Equations
Verified
Journal Article
Closed access
PDF file
JSJoginder Singh
Joginder Singh
SKSunil Kumar
Sunil Kumar
MKMukesh Kumar
Mukesh Kumar

28 June 2013 in Computer Methods in Biomechanics and Biomedical Engineering: Imaging & Visualization
Verified
Journal Article
Closed access
IFIsabel Figueiredo
Isabel Figueiredo
SKSunil Kumar
Sunil Kumar
CLCarlos Leal
Carlos Leal
PFPedro N. Figueiredo
Pedro N. Figueiredo
Wireless capsule endoscopy (WCE) has revolutionised the diagnosis and treatment of gastrointestinal tract, especially the small intestine where traditional endoscopies cannot reach. However, this new technology leads to the inspection of a large number of images, which is a time-consuming process and also too hard by naked eyes for doctors. In this paper, we propose a new computerised method for bleeding detection in WCE images. We use the second component of CIE Lab colour space together with appropriate segmentation and enhancement techniques, involving an adaptive anisotropic diffusion (alike Perona–Malik diffusion). As a result of this procedure, it is possible to devise four functions to discriminate between bleeding and normal regions in WCE images. These four bleeding detectors rely on the eigenvalues of the Hessian and on the Laplacian of the modified enhanced image. Multiscale image analysis approach is also involved in the definition of these detectors for handling the maximum and minimum sizes at which the bleeding regions are expected to be found. Experimental results on several medical data-sets show that the new algorithm achieves a very good rate of success and promising performance for bleeding detection.

13 July 2020 in Computational and Applied Mathematics
Verified
Journal Article
Closed access
PDF file
SUSumit
Sumit
SKSunil Kumar
Sunil Kumar
KUKuldeep
Kuldeep
MKMukesh Kumar
Mukesh Kumar