Filiep Vanpoucke

Dr. Filiep Vanpoucke

orcid

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2008 in Ear & Hearing
Verified
Journal Article
Closed access
CBCarlo K. Berenstein
Carlo K. Berenstein
LMLucas H. M. Mens
Lucas H. M. Mens
JMJef J. S. Mulder
Jef J. S. Mulder
FVFiliep Vanpoucke
Filiep Vanpoucke
To compare the effects of Monopole (Mono), Tripole (Tri), and “Virtual channel” (Vchan) electrode configurations on spectral resolution and speech perception in a crossover design. Nine experienced adults who received an Advanced Bionics CII/90K cochlear implant participated in a crossover design using three experimental strategies for 2 wk each. Three strategies were compared: (1) Mono; (2) Tri with current partly returning to adjacent electrodes and partly (25 or 75%) to the extracochlear reference; and (3) a monopolar “Vchan” strategy creating seven intermediate channels between two contacts. Each strategy was a variant of the standard “HiRes” processing strategy using 14 channels and 1105 pulses/sec/channel, and a pulse duration of 32 μsec/phase. Spectral resolution was measured using broadband noise with a sinusoidally rippled spectral envelope with peaks evenly spaced on a logarithmic frequency scale. Speech perception was measured for monosyllables in quiet and in steady-state and fluctuating noises. Subjective comments on music experience and preferences in everyday use were assessed through questionnaires. Thresholds and most comfortable levels with Mono and Vchan were both significantly lower than levels with Tri. Spectral resolution was significantly higher with Tri than with Mono; spectral resolution with Vchan did not differ significantly from the other configurations. Moderate but significant correlations between word recognition and spectral resolution were found in speech in quiet and fluctuating noise. For speech in quiet, word recognition was best with Mono and worst with Vchan; Tri did not significantly differ from the other configurations. Pooled across the noise conditions, word recognition was best with Tri and worst with Vchan (Mono did not significantly differ from the other configurations). These differences were small and insufficient to result in a clear increase in performance across subjects if the result from the best configuration per subject was compared with the result from Mono. Across all subjects, music appreciation and satisfaction in everyday use did not clearly differ between configurations. (1) Although spectral resolution was improved with the tripolar configuration, differences in speech performance were too small in this limited group of subjects to justify clinical introduction. (2) Overall spectral resolution remained extremely poor compared with normal hearing; it remains to be seen whether further manipulations of the electrical field will be more effective.

1 January 2006 in Acta Oto-Laryngologica
Verified
Journal Article
Closed access
APA. Postnov
A. Postnov
AZA. Zarowski
A. Zarowski
NCN. De Clerck
N. De Clerck
FVFiliep Vanpoucke
Filiep Vanpoucke
FOF.E. Offeciers
F.E. Offeciers
SPS. Peeters
S. Peeters
X-ray microtomography (micro-CT) is a new technique allowing for visualization of the internal structure of opaque specimens with a quasi-histological quality. Among multiple potential applications, the use of this technique in otology is very promising. Micro-CT appears to be ideally suited for in vitro visualization of the inner ear tissues as well as for evaluation of the electrode damage and/or surgical insertion trauma during implantation of the cochlear implant electrodes. This technique can greatly aid in design and development of new cochlear implant electrodes and is applicable for temporal bone studies. The main advantage of micro-CT is the practically artefact-free preparation of the samples and the possibility of evaluation of the interesting parameters along the whole insertion depth of the electrode. This paper presents the results of the first application of micro-CT for visualization of the inner ear structures in human temporal bones and for evaluation of the surgical positioning of the cochlear implant electrodes relative to the intracochlear soft tissues.

1 May 2004 in Otology & Neurotology
Verified
Journal Article
Closed access
FVFiliep Vanpoucke
Filiep Vanpoucke
AZAndrzej Zarowski
Andrzej Zarowski
JCJan Casselman
Jan Casselman
JFJohan HM Frijns
Johan HM Frijns
SPStefaan Peeters
Stefaan Peeters
Electrical properties of the implanted scala tympani could be accurately modeled by means of a simple resistive ladder network model. The subject-specific model parameters can be obtained from electrical field imaging (EFI) recordings. It is a powerful tool for analysis of the cochlear current spread. In EFI mode, the telemetry systems of contemporary cochlear implants can measure the intracochlear potential distribution. At present, the clinical use of EFI is typically limited to checking the implant’s proper functioning. Accurate EFI measurements and estimation algorithms have been developed to fit a small, yet physically relevant electrical model of the conductivity of the intracochlear structures. The model can attain up to 95% agreement with in vivo EFI data. A first discovery is that in a majority of the tested subjects, a substantial fraction of the monopolar current leaves the scala along the facial nerve canal. The role of the facial nerve canal has been confirmed by a temporal bone study and a high-resolution computed tomography (HRCT) scan in two of the implanted subjects. The clinical use of EFI is not limited to checking the implant’s status. For the Clarion II implant, a purely resistive model is able to match in vivo EFI recordings. The model indicates that the facial nerve canal is an important conduction path to the reference electrode. EFI can provide clinically relevant information, especially in problematic cases of cochlear malformations, postoperative fibrosis/ossification, implanted otosclerotic cochleae, postoperative facial nerve stimulation, increased stimulation thresholds, and so on.

24 October 2011 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
FVFiliep Vanpoucke
Filiep Vanpoucke
PBPeter-Paul B. Boermans
Peter-Paul B. Boermans
JFJohan HM Frijns
Johan HM Frijns
Correct placement of the electrode is crucial for cochlear implantation (CI) surgery. It determines the access to the auditory nerve and subsequent hearing performance. Here, we propose an objective measures tool that can partially verify the electrode position. The intracochlear spread of the electrical fields is measured and analyzed by means of multidimensional scaling resulting in an intuitive visual representation. The user can then detect major issues, such as electrode foldover or ossification. Other implantation issues, such as electrode migration into the scala vestibuli, may not significantly alter the electrical conduction pattern and remain undetected. Still, as the measurement is quick and readily available, it may be a valuable intraoperative verification tool.

1 January 2009 in Acta Oto-Laryngologica
Verified
Journal Article
Closed access
JFJohan HM Frijns
Johan HM Frijns
RKRandy K. Kalkman
Randy K. Kalkman
FVFiliep Vanpoucke
Filiep Vanpoucke
JBJorien Snel Bongers
Jorien Snel Bongers
JBJeroen J. Briaire
Jeroen J. Briaire
Conclusion: There are two modalities of dual electrode stimulation: a shifting, continuous excitation, which is the desired effect, and a split excitation with considerable variation in loudness. The first one most likely occurs in the basal turn, with adjacent contacts, stimulated simultaneously rather than sequentially. Objectives: This study examines the effects on place pitch and loudness of simultaneous current steering and sequential stimulation. These can give cochlear implant patients access to more perceptual channels than physical contacts in the electrode array. Materials and methods: For both lateral wall and perimodiolar electrodes, simultaneous current steering as well as sequential stimulation, place pitch and loudness of the percept were predicted with a computational model of the implanted human cochlea. The loudness predictions were validated with psychophysical loudness balancing experiments. Results: Simultaneous stimulation with adjacent electrode contacts in the basal end of the cochlea was generally able to produce a single, gradually shifting intermediate pitch percept. Simultaneous stimulation beyond the first cochlear turn, sequential stimulation and simultaneous stimulation with non-adjacent electrode contacts often produced two regions of excitation. In the case of sequential stimulation the total amount of current to reach most comfortable loudness was raised, both in the model and in the patients.

15 April 2016
Verified
Book Chapter
Open access
PDF file
DVDeborah Vickers
Deborah Vickers
ADAneeka Degun
Aneeka Degun
ACAngela Canas
Angela Canas
TSThomas Stainsby
Thomas Stainsby
FVFiliep Vanpoucke
Filiep Vanpoucke
There is a wide range in performance for cochlear implant (CI) users and there is some evidence to suggest that implant fitting can be modified to improve performance if electrodes that do not provide distinct pitch information are de-activated. However, improvements in performance may not be the same for users of all CI devices; in particular for those with Cochlear devices using n-of-m strategies (ACE or SPEAK). The goal of this research was to determine for users of Cochlear devices (CP810 or CP900 series processors) if speech perception could be improved when indiscriminable electrodes were de-activated and this was also compared to when the same number of discriminable electrodes were de-activated. A cross-over study was conducted with 13 adult CI users who received experimental maps with de-activated channels for a minimum of 2 months and these were compared to optimised clinical maps. The findings showed that there were no significant benefits of electrode de-activation on speech perception and that there was a significant deterioration in spectro-temporal ripple perception when electrodes were switched off. There were no significant differences between de-activation of discriminable or indiscriminable electrodes. These findings suggest that electrode de-activation with n-of-m strategies may not be beneficial.