Xianling Dong

Prof. Xianling Dong

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2020 in Cancer Imaging
Verified
Journal Article
Open access
PDF file
XDXianling Dong
Xianling Dong
SXShiqi Xu
Shiqi Xu
YLYanli Liu
Yanli Liu
AWAihui Wang
Aihui Wang
MSM. Iqbal Saripan
M. Iqbal Saripan
Lijun LuLijun Lu
Lijun Lu
Background: Convolutional neural networks (CNNs) have been extensively applied to two-dimensional (2D) medical image segmentation, yielding excellent performance. However, their application to three-dimensional (3D) nodule segmentation remains a challenge.Methods: In this study, we propose a multi-view secondary input residual (MV-SIR) convolutional neural network model for 3D lung nodule segmentation using the Lung Image Database Consortium and Image Database Resource Initiative (LIDC-IDRI) dataset of chest computed tomography (CT) images. Lung nodule cubes are prepared from the sample CT images. Further, from the axial, coronal, and sagittal perspectives, multi-view patches are generated with randomly selected voxels in the lung nodule cubes as centers. Our model consists of six submodels, which enable learning of 3D lung nodules sliced into three views of features; each submodel extracts voxel heterogeneity and shape heterogeneity features. We convert the segmentation of 3D lung nodules into voxel classification by inputting the multi-view patches into the model and determine whether the voxel points belong to the nodule. The structure of the secondary input residual submodel comprises a residual block followed by a secondary input module. We integrate the six submodels to classify whether voxel points belong to nodules, and then reconstruct the segmentation image.Results: The results of tests conducted using our model and comparison with other existing CNN models indicate that the MV-SIR model achieves excellent results in the 3D segmentation of pulmonary nodules, with a Dice coefficient of 0.926 and an average surface distance of 0.072.Conclusion: our MV-SIR model can accurately perform 3D segmentation of lung nodules with the same segmentation accuracy as the U-net model.

6 June 2024 in BMC Medical Imaging
Verified
Journal Article
Open access
PDF file
XZXiaolei Zhang
Xiaolei Zhang
MSM. Iqbal bin Saripan
M. Iqbal bin Saripan
YWYanjun Wu
Yanjun Wu
ZWZhongxiao Wang
Zhongxiao Wang
DWDong Wen
Dong Wen
XDXianling Dong
Xianling Dong
Background: This study investigated whether the Combat compensation method can remove the variability of radiomic features extracted from different scanners, while also examining its impact on the subsequent predictive performance of machine learning models. Materials and methods: 135 CT images of Credence Cartridge Radiomic phantoms were collected and screened from three scanners manufactured by Siemens, Philips, and GE. 100 radiomic features were extracted and 20 radiomic features were screened according to the Lasso regression method. The radiomic features extracted from the rubber and resin-filled regions in the cartridges were labeled into different categories for evaluating the performance of the machine learning model. Radiomics features were divided into three groups based on the different scanner manufacturers. The radiomic features were randomly divided into training and test sets with a ratio of 8:2. Five machine learning models (lasso, logistic regression, random forest, support vector machine, neural network) were employed to evaluate the impact of Combat on radiomic features. The variability among radiomic features were assessed using analysis of variance (ANOVA) and principal component analysis (PCA). Accuracy, precision, recall, and area under the receiver curve (AUC) were used as evaluation metrics for model classification. Results: The principal component and ANOVA analysis results show that the variability of different scanner manufacturers in radiomic features was removed (P˃0.05). After harmonization with the Combat algorithm, the distributions of radiomic features were aligned in terms of location and scale. The performance of machine learning models for classification improved, with the Random Forest model showing the most significant enhancement. The AUC value increased from 0.88 to 0.92. Conclusions: The Combat algorithm has reduced variability in radiomic features from different scanners. In the phantom CT dataset, it appears that the machine learning model’s classification performance may have improved after Combat harmonization. However, further investigation and validation are required to fully comprehend Combat’s impact on radiomic features in medical imaging.

14 May 2023 in Thoracic Cancer
Verified
Journal Article
Open access
XZXiaolei Zhang
Xiaolei Zhang
XDXianling Dong
Xianling Dong
MSM. Iqbal bin Saripan
M. Iqbal bin Saripan
DDDongyang Du
Dongyang Du
YWYanjun Wu
Yanjun Wu
MMMohammad Hamiruce Marhaban
Mohammad Hamiruce Marhaban
Background: Radiomic diagnosis models generally consider only a single dimension of information, leading to limitations in their diagnostic accuracy and reliability. The integration of multiple dimensions of information into the deep learning model have the potential to improve its diagnostic capabilities. The purpose of study was to evaluate the performance of deep learning model in distinguishing tuberculosis (TB) nodules and lung cancer (LC) based on deep learning features, radiomic features, and clinical information. Methods: Positron emission tomography (PET) and computed tomography (CT) image data from 97 patients with LC and 77 patients with TB nodules were collected. One hundred radiomic features were extracted from both PET and CT imaging using the pyradiomics platform, and 2048 deep learning features were obtained through a residual neural network approach. Four models included traditional machine learning model with radiomic features as input (traditional radiomics), a deep learning model with separate input of image features (deep convolutional neural networks [DCNN]), a deep learning model with two inputs of radiomic features and deep learning features (radiomics‐DCNN) and a deep learning model with inputs of radiomic features and deep learning features and clinical information (integrated model). The models were evaluated using area under the curve (AUC), sensitivity, accuracy, specificity, and F1‐score metrics. Results: The results of the classification of TB nodules and LC showed that the integrated model achieved an AUC of 0.84 (0.82–0.88), sensitivity of 0.85 (0.80–0.88), and specificity of 0.84 (0.83–0.87), performing better than the other models. Conclusion: The integrated model was found to be the best classification model in the diagnosis of TB nodules and solid LC.

1 April 2022 in Neural Networks
Verified
Journal Article
Closed access
DWDong Wen
Dong Wen
RLRou Li
Rou Li
MJMengmeng Jiang
Mengmeng Jiang
JLJingjing Li
Jingjing Li
YLYijun Liu
Yijun Liu
YZYanhong Zhou
Yanhong Zhou

4 May 2023 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
DWDong Wen
Dong Wen
BLBingbing Liang
Bingbing Liang
JLJingjing Li
Jingjing Li
LWLingyu Wu
Lingyu Wu
XWXianglong Wan
Xianglong Wan
YZYanhong Zhou
Yanhong Zhou
In order to improve the traditional common space pattern (CSP) algorithm pattern in EEG feature extraction, this study proposes a feature extraction method of EEG signals based on permutation conditional mutual information common space pattern (PCMICSP), which used the sum of the permutation condition mutual information matrices of each lead to replacing the mixed spatial covariance matrix in the traditional CSP algorithm, and its eigenvectors and eigenvalues are used to construct a new spatial filter. Then the spatial features in the different time domains and frequency domains are combined to construct the two-dimensional pixel map, Finally, a convolutional neural network (CNN) is used for binary classification. The EEG signals of 7 community elderly before and after spatial cognitive training in virtual reality (VR) scenes were used as the test data set. The average classification accuracy of the PCMICSP algorithm for pre-test and post-test EEG signals is 98%, which was higher than that of CSP based on CMI (conditional mutual information), CSP based on MI (mutual information), and traditional CSP in the combination of four frequency bands. Compared with the traditional CSP method, PCMICSP can be used as a more effective method to extract the spatial features of EEG signals. Therefore, this paper provides a new approach to solving the strict linear hypothesis of CSP and can be used as a valuable biomarker for the spatial cognitive evaluation of the elderly in the community.

13 February 2023 in EJNMMI Research
Verified
Journal Article
Open access
PDF file
BWBingzhen Wang
Bingzhen Wang
JLJinghua Liu
Jinghua Liu
XZXiaolei Zhang
Xiaolei Zhang
ZWZhongxiao Wang
Zhongxiao Wang
ZCZhendong Cao
Zhendong Cao
XDXianling Dong
Xianling Dong
Objectives: By comparing the prognostic performance of 18F-FDG PET/CT-based radiomics combining dose features [Includes Dosiomics feature and the dose volume histogram (DVH) features] with that of conventional radiomics in head and neck cancer (HNC), multidimensional prognostic models were constructed to investigate the overall survival (OS) in HNC. Materials and methods: A total of 220 cases from four centres based on the Cancer Imaging Archive public dataset were used in this study, 2260 radiomics features and 1116 dosiomics features and 8 DVH features were extracted for each case, and classified into seven different models of PET, CT, Dose, PET+CT, PET+Dose, CT+Dose and PET+CT+Dose. Features were selected by univariate Cox and Spearman correlation coefficients, and the selected features were brought into the least absolute shrinkage and selection operator (LASSO)-Cox model. A nomogram was constructed to visually analyse the prognostic impact of the incorporated dose features. C-index and Kaplan–Meier curves (log-rank analysis) were used to evaluate and compare these models. Results: The cases from the four centres were divided into three different training and validation sets according to the hospitals. The PET+CT+Dose model had C-indexes of 0.873 (95% CI 0.812–0.934), 0.759 (95% CI 0.663–0.855) and 0.835 (95% CI 0.745–0.925) in the validation set respectively, outperforming the rest models overall. The PET+CT+Dose model did well in classifying patients into high- and low-risk groups under all three different sets of experiments (p < 0.05). Conclusion: Multidimensional model of radiomics features combining dosiomics features and DVH features showed high prognostic performance for predicting OS in patients with HNC.