Étienne LABYT

Dr. Étienne LABYT

CEA LETI, MINATEC Campus, University Grenoble Alpes, F-38000 Grenoble, France

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 December 2011 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Closed access
CWCatherine Wacongne
Catherine Wacongne
ELEtienne Labyt
Etienne Labyt
VWVirginie van Wassenhove
Virginie van Wassenhove
TBTristan Bekinschtein
Tristan Bekinschtein
LNLionel Naccache
Lionel Naccache
SDStanislas Dehaene
Stanislas Dehaene
According to hierarchical predictive coding models, the cortex constantly generates predictions of incoming stimuli at multiple levels of processing. Responses to auditory mismatches and omissions are interpreted as reflecting the prediction error when these predictions are violated. An alternative interpretation, however, is that neurons passively adapt to repeated stimuli. We separated these alternative interpretations by designing a hierarchical auditory novelty paradigm and recording human EEG and magnetoencephalographic (MEG) responses to mismatching or omitted stimuli. In the crucial condition, participants listened to frequent series of four identical tones followed by a fifth different tone, which generates a mismatch response. Because this response itself is frequent and expected, the hierarchical predictive coding hypothesis suggests that it should be cancelled out by a higher-order prediction. Three consequences ensue. First, the mismatch response should be larger when it is unexpected than when it is expected. Second, a perfectly monotonic sequence of five identical tones should now elicit a higher-order novelty response. Third, omitting the fifth tone should reveal the brain's hierarchical predictions. The rationale here is that, when a deviant tone is expected, its omission represents a violation of two expectations: a local prediction of a tone plus a hierarchically higher expectation of its deviancy. Thus, such an omission should induce a greater prediction error than when a standard tone is expected. Simultaneous EEE- magnetoencephalographic recordings verify those predictions and thus strongly support the predictive coding hypothesis. Higher-order predictions appear to be generated in multiple areas of frontal and associative cortices.

16 July 2018 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
ELEtienne Labyt
Etienne Labyt
MCMarie-Constance Corsi
Marie-Constance Corsi
WFWilliam Fourcault
William Fourcault
ALAugustin Palacios Laloy
Augustin Palacios Laloy
FBFrancis Bertrand
Francis Bertrand
SMSophie Morales
Sophie Morales
In this paper, we present the first proof of concept confirming the possibility to record magnetoencephalographic (MEG) signals with Optically Pumped Magnetometers (OPMs) based on the parametric resonance of 4He atoms. The main advantage of this kind of OPM is the possibility to provide a tri-axis vector measurement of the magnetic field at room-temperature (the 4He vapor is neither cooled nor heated). The sensor achieves a sensitivity of 210 fT/√Hz in the bandwidth [2 Hz - 300 Hz]. MEG simulation studies with a brain phantom were cross-validated with real MEG measurements on a healthy subject. For both studies, MEG signal was recorded consecutively with OPMs and Superconducting Quantum Interference Devices (SQUIDs) used as reference sensors. For healthy subject MEG recordings, three MEG proofs of concept were carried out: auditory and visual evoked fields (AEF, VEF), and spontaneous activity. M100 peaks have been detected on evoked responses recorded by both OPMs and SQUIDs with no significant difference in latency. Concerning spontaneous activity, an attenuation of the signal power between 8-12 Hz (alpha band) related to eyes opening has been observed with OPM similarly to SQUID. All these results confirm that the room temperature vector 4He OPMs can record MEG signals and provide reliable information on brain activity.

28 April 2021 in Optics Express
Verified
Journal Article
Closed access
WFWilliam Fourcault
William Fourcault
RRRudy Romain
Rudy Romain
GGGwenael Le Gal
Gwenael Le Gal
FBFrançois Bertrand
François Bertrand
VJVincent Josselin
Vincent Josselin
APAgustin Palacios-Laloy
Agustin Palacios-Laloy
Optically-pumped magnetometers constitute a valuable tool for imaging biological magnetic signals without cryogenic cooling. Nowadays, numerous developments are being pursued using alkali-based magnetometers, which have demonstrated excellent sensitivities in the spin-exchange relaxation free (SERF) regime that requires heating to >100 °C. In contrast, metastable helium-4 based magnetometers work at any temperature, which allows a direct contact with the scalp, yielding larger signals and a better patient comfort. However former 4He magnetometers displayed large noises of >200 fT/Hz1/2 with 300-Hz bandwidth. We describe here an improved magnetometer reaching a sensitivity better than 50 fT/Hz1/2, nearly the photon shot noise limit, with a bandwidth of 2 kHz. Like other zero-field atomic magnetometers, these magnetometers can be operated in closed-loop architecture reaching several hundredths nT of dynamic range. A small array of 4 magnetometers operating in a closed loop has been tested with a successful correction of the cross-talks.

3 March 2023 in Sensors
Verified
Journal Article
Open access
PDF file
TGTjerk P. Gutteling
Tjerk P. Gutteling
MBMathilde Bonnefond
Mathilde Bonnefond
TCTommy Clausner
Tommy Clausner
SDSébastien Daligault
Sébastien Daligault
RRRudy Romain
Rudy Romain
DSDenis Pierre Schwartz
Denis Pierre Schwartz
MagnetoEncephaloGraphy (MEG) provides a measure of electrical activity in the brain at a millisecond time scale. From these signals, one can non-invasively derive the dynamics of brain activity. Conventional MEG systems (SQUID-MEG) use very low temperatures to achieve the necessary sensitivity. This leads to severe experimental and economical limitations. A new generation of MEG sensors is emerging: the optically pumped magnetometers (OPM). In OPM, an atomic gas enclosed in a glass cell is traversed by a laser beam whose modulation depends on the local magnetic field. MAG4Health is developing OPMs using Helium gas (4He-OPM). They operate at room temperature with a large dynamic range and a large frequency bandwidth and output natively a 3D vectorial measure of the magnetic field. In this study, five 4He-OPMs were compared to a classical SQUID-MEG system in a group of 18 volunteers to evaluate their experimental performances. Considering that the 4He-OPMs operate at real room temperature and can be placed directly on the head, our assumption was that 4He-OPMs would provide a reliable recording of physiological magnetic brain activity. Indeed, the results showed that the 4He-OPMs showed very similar results to the classical SQUID-MEG system by taking advantage of a shorter distance to the brain, despite having a lower sensitivity.

23 October 2021 in Sensors
Verified
Journal Article
Open access
PDF file
LDLouis Devillaine
Louis Devillaine
RLRaphael Lambert
Raphael Lambert
JBJerome Boutet
Jerome Boutet
SASaifeddine Aloui
Saifeddine Aloui
VBVincent Brault
Vincent Brault
ELEtienne Labyt
Etienne Labyt
Five to ten percent of school-aged children display dysgraphia, a neuro-motor disorder that causes difficulties in handwriting, which becomes a handicap in the daily life of these children. Yet, the diagnosis of dysgraphia remains tedious, subjective and dependent to the language besides stepping in late in the schooling. We propose a pre-diagnosis tool for dysgraphia using drawings called graphomotor tests. These tests are recorded using graphical tablets. We evaluate several machine-learning models and compare them to build this tool. A database comprising 305 children from the region of Grenoble, including 43 children with dysgraphia, has been established and diagnosed by specialists using the BHK test, which is the gold standard for the diagnosis of dysgraphia in France. We performed tests of classification by extracting, correcting and selecting features from the raw data collected with the tablets and achieved a maximum accuracy of 73% with cross-validation for three models. These promising results highlight the relevance of graphomotor tests to diagnose dysgraphia earlier and more broadly.

18 April 2022 in Sensors
Verified
Journal Article
Open access
PDF file
SZSAEED ZAHRAN
SAEED ZAHRAN
MMMahdi Mahmoudzadeh
Mahdi Mahmoudzadeh
FWFabrice Wallois
Fabrice Wallois
NBNacim Betrouni
Nacim Betrouni
PDPhilippe Derambure
Philippe Derambure
ELEtienne Labyt
Etienne Labyt
Optically pumped magnetometers (OPMs) are new, room-temperature alternatives to superconducting quantum interference devices (SQUIDs) for measuring the brain’s magnetic fields. The most used OPM in MagnetoEncephaloGraphy (MEG) are based on alkali atoms operating in the spin-exchange relaxation-free (SERF) regime. These sensors do not require cooling but have to be heated. Another kind of OPM, based on the parametric resonance of 4He atoms are operated at room temperature, suppressing the heat dissipation issue. They also have an advantageous bandwidth and dynamic range more suitable for MEG recordings. We quantitatively assessed the improvement (relative to a SQUID magnetometers array) in recording the magnetic field with a wearable 4He OPM-MEG system through data simulations. The OPM array and magnetoencephalography forward models were based on anatomical MRI data from an adult, a nine-year-old child, and 10 infants aged between one month and two years. Our simulations showed that a 4He OPMs array offers markedly better spatial specificity than a SQUID magnetometers array in various key performance areas (e.g., signal power, information content, and spatial resolution). Our results are also discussed regarding previous simulation results obtained for alkali OPM.