Liu YANG

Dr. Liu YANG


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 June 2022 in Buildings
Verified
Journal Article
Open access
PDF file
HWHaitao Wang
Haitao Wang
YHYuge Huang
Yuge Huang
Liu YANGLiu YANG
Liu YANG
The design of thermal insulation in roofs is very important to reduce energy consumption and decrease the environmental impacts of buildings. An integrated economic and environmental assessment-based optimization design method is presented in this paper to find the best candidate insulation design scheme for building roofs, including the determination of roof thermal insulation type and the optimum insulation thickness. In the optimization design method, a zonal method-based double-skin ventilation roof heat transfer model is developed to predict the roof energy consumption. Economic and environmental benefits due to thermal insulation are calculated by using the economic analysis model, the environmental analysis model, and roof energy consumption. Moreover, an integrated dimensionless economic and environmental assessment index is proposed to evaluate different roof thermal insulation design schemes. The optimum insulation thickness is determined by maximizing the sum of economic benefit and environmental benefit due to thermal insulation. The validation results in a real building show that the predicted data for the zonal-based double-skin ventilation roof heat transfer model agreed well with the measured data, with a maximum relative error of 8.2%. The optimum insulation thickness of extruded polystyrene (EPS), mineral wool (MW), and polyurethane (PU) was between 0.082 m and 0.171 m for the single-skin roof in a low-temperature granary in Changsha region in China. The ranking of the integrated assessment indexes of thermal insulation is EPS > MW > PU. A double-skin ventilation roof can reduce the optimum thickness of thermal insulation. The best result is obtained by EPS for the double-skin roof with a grey outer surface color for the low-temperature granary roof in Changsha region in China. The influencing factors of insulation type, roof structure, and roof outer-surface color should be considered in finding the best candidate insulation design solution for building roofs. The integrated economic and environmental assessment-based optimization design method can help designers to efficiently find the best design scheme of thermal insulation to maximize the sum of economic benefit and environmental benefit for building roofs.

14 June 2023 in Processes
Verified
Journal Article
Open access
PDF file
SZShuizhong Zhao
Shuizhong Zhao
JSJiangfeng Si
Jiangfeng Si
GCGang Chen
Gang Chen
HSHong Shi
Hong Shi
YLYusong Lei
Yusong Lei
Liu YANGLiu YANG
Liu YANG
In the energy-saving design of substations, the building envelope thermal parameters, window-to-wall ratio, and shape factor are three crucial influencing factors. They not only affect the building’s appearance but also have an important impact on the total building energy consumption. In this paper, we applied the energy consumption simulation software DeST-c to study the influence of the above three elements on the total energy consumption of the building in a representative city with different thermal zones. The optimal envelope thermal parameters, optimal window-to-wall ratio, and optimal shape factor were derived through combination with economic analysis. Finally, the sensitivity analysis of different elements was carried out to determine the suitable passive design solutions for substations in different climate zones. It was found that the thickness of roof insulation has the greatest influence on the energy consumption of substation buildings among all envelopes. The optimal window-to-wall ratios were 0.4, 0.4~0.5, 0.3, 0.3~0.4, and 0.5 for severe cold, cold, hot summer and cold winter, hot summer and warm winter, and mild regions, respectively; and the optimal shape factors were 0.29, 0.30, 0.23, 0.31, and 0.33, respectively. The conclusions of this study can provide architects with energy-saving design strategies and suggestions for substations in different climate zones, and provide references for building energy-saving designs and air conditioning and heating equipment selection.

15 March 2024 in Building and Environment
Verified
Journal Article
Closed access
Liu YANGLiu YANG
Liu YANG
YXYudong Xia
Yudong Xia
XCXi Chen
Xi Chen
YCYan Chen
Yan Chen
WLWeilin Li
Weilin Li

4 September 2023 in Processes
Verified
Journal Article
Open access
PDF file
XCXi Chen
Xi Chen
YGYahui Gao
Yahui Gao
Liu YANGLiu YANG
Liu YANG
YLYang Liu
Yang Liu
MQMiaomiao Qin
Miaomiao Qin
PWPeng Wang
Peng Wang
In order to explore the indoor air quality during different cooking procedures, a very common kitchen in China is selected for experimental research. An indoor air quality meter is used to measure the temperature, relative humidity, and CO and CO2 concentrations of the indoor air above the stove when people cook four different dishes under different ventilation patterns in the kitchen. The results indicate that the heat and gas consumed during cooking are closely related to the temperature and concentrations of CO and CO2. Some cooking procedures such as boiling water are related to the indoor air temperature and relative humidity in the kitchen. In addition, in kitchens without mechanical ventilation, natural ventilation shows a more significant positive effect on controlling temperature, relative humidity, and concentrations of CO and CO2 during cooking procedures.

10 September 2024 in Buildings
Verified
Journal Article
Open access
PDF file
Liu YANGLiu YANG
Liu YANG
XZXiang Zhao
Xiang Zhao
HWHaitao Wang
Haitao Wang
WBWenfeng Bi
Wenfeng Bi
SLShengnan Liu
Shengnan Liu
This study introduces a novel direct expansion air conditioning (DX AC) system with three evaporators (DX-TE) to enhance indoor temperature and humidity control. Operating in two modes, the DX-TE system provides variable cooling output, adapting to fluctuating indoor cooling loads while maintaining uniform air supply. Experimental and simulation studies were conducted to investigate the system’s operational characteristics. An experimental setup was established to obtain preliminary steady-state data, followed by the development and validation of a steady-state mathematical model. Simulation studies were then performed to optimize the evaporator sizes. The results indicate that the DX-TE system delivers variable cooling capacities at a constant compressor speed and airflow rate, outperforming conventional variable frequency DX AC systems in cooling and dehumidification. The evaporator area ratio significantly impacts the system’s performance, with smaller ratios yielding a larger output range. As the area ratio increases from 1:1 to 1:3, the cooling capacity range in Modes 1 and 2 increases by 33.6% and 14.3%, respectively, while the dehumidification range expands by 58.6% and 51.69%.

26 September 2025 in Buildings
Verified
Journal Article
Open access
PDF file
XCXi Chen
Xi Chen
YLYaning Li
Yaning Li
SJShuai Jiang
Shuai Jiang
Liu YANGLiu YANG
Liu YANG
YLYang Liu
Yang Liu
HZHao Zhang
Hao Zhang
Underground granaries offer natural insulation for long-term grain storage, yet spatial heterogeneity in temperature and humidity can drive condensation and degrade grain quality. To address this issue, mechanical ventilation is commonly employed, yet evidence remains limited on whether pretreating the inlet air before ventilation can further reduce the risk of condensation. In order to bridge this gap, a custom-designed small-scale underground granary was employed, in which temperature and relative humidity of the grain pile, surrounding soil, and ambient air were monitored at 28 sampling points. The effectiveness of mechanical ventilation and ventilation pretreatment in reducing condensation was also assessed. Results demonstrated that during static storage, the granary was minimally affected by external conditions. Yet, a high temperature and humidity area developed at the top of the grain pile over the 24-day period of static storage. Under mechanical ventilation, local relative humidity decreased but grain temperature still responded to ambient conditions. In contrast, ventilation pretreatment stabilized inlet air, lowered peak grain temperature by 1 °C, and improved relative humidity reduction from 6% to 12%. This produced a more uniform temperature–humidity profile and markedly reduced condensation risk.