Farida Lamkarkach

Mrs. Farida Lamkarkach


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2021 in Environment International
Verified
Journal Article
Open access
FLFarida Lamkarkach
Farida Lamkarkach
EOEva Ougier
Eva Ougier
RGRobert Garnier
Robert Garnier
CVClaude Viau
Claude Viau
MKMarike Kolossa-Gehring
Marike Kolossa-Gehring
PAPetra Apel
Petra Apel
The methodology agreed within the framework of the HBM4EU project is used in this work to derive HBM-GVs for the general population (HBM-GVGenPop) and for workers (HBM-GVWorker) exposed to cadmium (Cd) and its compounds. For Cd, a significant number of epidemiological studies with dose-response relationships are available, in particular for kidney effects. These effects are described in terms of a relation between urinary Cd (U-Cd) or blood Cd (B-Cd) levels and low molecular weight proteinuria (LMWP) markers like beta-2-microglobulin (β2M) and retinol-binding protein (RBP). In order to derive HBM-GVs for the general population and workers, an assessment of data from evaluations conducted by national or international organisations was undertaken. In this work, it appeared relevant to select renal effects as the critical effect for the both groups, however, differences between general population (including sensitive people) and workers (considered as an homogenous population of adults who should not be exposed to Cd if they suffer from renal diseases) required the selection of different key studies (i.e. conducted in general population for HBM-GVGenPop and at workplace for HBM-GVWorker). For U-Cd, a HBM-GVGenPop of 1 µg/g creatinine (creat) is recommended for adults older than 50 years, based on a robust meta-analysis performed by EFSA (EFSA, 2009a). To take into account the accumulation of Cd in the human body throughout life, threshold or 'alert' values according to age were estimated for U-Cd. At workplace, a HBM-GVWorker of 2 μg/g creat is derived from the study of Chaumont et al., (2011) for U-Cd, and in addition to this recommendation a HBM-GVworker for B-Cd of 5 µg/L is also proposed. The HBM-GVWorker for U-Cd is similar to the biological limit value (BLV) set by the new amendment of the European Carcinogens and Mutagens Directive in June 2019 (2 µg/g creat for U-Cd).

31 May 2022 in Toxics
Verified
Journal Article
Open access
PDF file
FLFarida Lamkarkach
Farida Lamkarkach
MMMatthieu Meslin
Matthieu Meslin
MKMarike Kolossa-Gehring
Marike Kolossa-Gehring
PAPetra Apel
Petra Apel
RGRobert Garnier
Robert Garnier
Within the European Joint Program on Human Biomonitoring HBM4EU, human biomonitoring guidance values (HBM-GVs) for the general population (HBM-GVGenPop) or for occupationally exposed adults (HBM-GVWorker) are derived for prioritized substances including dimethylformamide (DMF). The methodology to derive these values that was agreed upon within the HBM4EU project was applied. A large database on DMF exposure from studies conducted at workplaces provided dose–response relationships between biomarker concentrations and health effects. The hepatotoxicity of DMF has been identified as having the most sensitive effect, with increased liver enzyme concentrations serving as biomarkers of the effect. Out of the available biomarkers of DMF exposure studied in this paper, the following were selected to derive HBM-GVWorker: total N-methylformamide (tNMF) (sum of N-hydroxymethyl-N-methylformamide and NMF) and N-acetyl-S-(N-methylcarbamoyl)cysteine (AMCC) in urine. The proposed HBM-GVWorker is 10 mg·L−1 or 10 mg·g−1 creatinine for both biomarkers. Due to their different half-lives, tNMF (representative of the exposure of the day) and AMCC (representative of the preceding days’ exposure) are complementary for the biological monitoring of workers exposed to DMF. The levels of confidence for these HBM-GVWorker are set to “high” for tNMF and “medium-low” for AMCC. Therefore, further investigations are required for the consolidation of the health-based HBM-GV for AMCC in urine.