xiaojun ren

Dr. xiaojun ren


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 January 2020 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
SCShaohua Chen
Shaohua Chen
YZYunlong Zhao
Yunlong Zhao
HQHaitao Qiu
Haitao Qiu
XRxiaojun ren
xiaojun ren

14 December 2018 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
XRxiaojun ren
xiaojun ren
MFMing FENG
Ming FENG
TRTianming Ren
Tianming Ren
High temperature superconducting magnetic bear-ings can be suspended without contact and self-stability. They are widely used in many industries. Before the actual production of magnetic bearings, the structural design and parameter opti-mization are very important. The design and optimization meth-od of radial high temperature magnetic bearing are studied in this paper. The force calculation expression was deduced. The bearing capacity of high temperature magnetic bearings was op-timized. The performance of the radial HTSMB was analyzed and verified by FEM

17 November 2022 in IET Electric Power Applications
Verified
Journal Article
Open access
XRxiaojun ren
xiaojun ren
MFMing Feng
Ming Feng
TRTianming Ren
Tianming Ren
Combined magnetic bearing with radial and axial unites is an important supporting element for high speed and high energy density motor. Accurate calculation of the magnetic field is a key to design and optimise a Combined Radial and Axial Magnetic Bearing (CRAMB). This study focuses on magnetic field analytical calculation method for radial Unite of CRAMB. The analytical calculation model of magnetic field is based on subdomain method. The Laplace's equations in the air‐gap subdomain are solved by the variable separation method. The magnetic field of magnetic bearing with large diameter rotor is analysed and calculated in Cartesian coordinate system. Considering the influence of curvature the magnetic field distribution of magnetic bearing with small diameter rotor is deduced and calculated analytically in polar coordinate system. The effectiveness of the analytical method is verified by finite element and experimental results.

3 June 2024 in Energies
Verified
Journal Article
Open access
PDF file
XRxiaojun ren
xiaojun ren
MFMing FENG
Ming FENG
JLJinliang Liu
Jinliang Liu
RDRui Du
Rui Du
The hydrogen oxygen fuel cell is a power source with significant potential for development. The air compressor provides ample oxygen for the fuel cell, and as a key component of the air compressor, the performance of the motor greatly impacts the efficiency of the fuel cell. In order to enhance the system performance of high-speed permanent magnet motors, optimization was conducted on the motor’s geometric dimensions to minimize rotor loss and maximize power density, taking into account the comprehensive constraints of electromagnetic and mechanical properties. The finite-element method was employed to analyze the motor’s performance, conducting a multi-physical field analysis that included electromagnetic field, rotor loss, and mechanical strength analysis, as well as temperature field analysis. Aiming at the problem of high temperature rise in high-speed motor winding, the influence of the cooling water flow rate on the winding temperature rise was analyzed and simulated. Based on the analysis results, the minimum cooling water flow rate was obtained. According to the optimized design results, a prototype of an 18 kW, 100,000 rpm motor was manufactured, and the efficiency and temperature rise were tested. The experimental results verify the correctness and effectiveness of the optimal design.

11 October 2024 in Energies
Verified
Journal Article
Open access
PDF file
XRxiaojun ren
xiaojun ren
ZCZhikai Chen
Zhikai Chen
RDRui Du
Rui Du
MFMing FENG
Ming FENG
Reducing heat and improving the overall operation stability of the motor play a key role in the design of a starting engine. This paper focuses on the loss and thermal analysis of a permanent magnet (PM) brushless machine used in starter generators. The loss of the starter generator was calculated through a combination of theoretical analysis and the finite element method. A thermal analysis model was established based on the division of the fluid domain, boundary grid, heat source setting, and so on. The temperature fields of the whole motor and the main components were calculated and analyzed. The main factors affecting the air cooling effect were analyzed, including air flow rate, air temperature, and motor speed. A prototype experimental platform of the SG motor was built. The efficiency and temperature rise in the motor were tested. The temperature values were compared with the calculated values. The experimental results show that the performance of the motor is excellent, and the error between the temperature and the design calculation is less than 10% under each load torque. The accuracy of the thermal analysis method is verified. The correctness of the motor transient model was also confirmed through a temperature rise experiment under rated conditions, providing a research basis for improving operation efficiency.

13 July 2021 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
XRxiaojun ren
xiaojun ren
MFMing Feng
Ming Feng
SCShaohua Chen
Shaohua Chen
Asymmetric three-pole magnetic bearings (MBs) have higher power density and lower cost, compared to the symmetrical magnetic bearings with four poles or eight poles. This paper presents a new asymmetric three-pole structure with secondary air-gap for a radial magnetic bearing. Asymmetric permanent magnet (PM) biased MB can produce a static levitation force by bias magnetic flux. The secondary air-gap can ensure that the armature winding flux and PM flux are separated. The configures of the proposed MB are demonstrated. Analytical model with equivalent magnetic circuit method is deduced. The design method based on asymmetry factor is proposed for the three-pole MB (TPMB). The characteristics of the TPMB such as magnetic flux distribution and magnetic levitation force are analyzed by the finite-element method (FEM). The design values and FEM results are compared to validate the effectiveness of the presented design method.