Clement Blanchet

Dr. Clement Blanchet


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 March 2015 in Journal of Applied Crystallography
Verified
Journal Article
Open access
PDF file
CBClement Blanchet
Clement Blanchet
ASAlessandro Spilotros
Alessandro Spilotros
FSFrank Schwemmer
Frank Schwemmer
MGMelissa A. Graewert
Melissa A. Graewert
AKAlexey Kikhney
Alexey Kikhney
DSDmitri I. Svergun
Dmitri I. Svergun
A high-brilliance synchrotron P12 beamline of the EMBL located at the PETRA III storage ring (DESY, Hamburg) is dedicated to biological small-angle X-ray scattering (SAXS) and has been designed and optimized for scattering experiments on macromolecular solutions. Scatterless slits reduce the parasitic scattering, a custom-designed miniature active beamstop ensures accurate data normalization and the photon-counting PILATUS 2M detector enables the background-free detection of weak scattering signals. The high flux and small beam size allow for rapid experiments with exposure time down to 30–50 ms covering the resolution range from about 300 to 0.5 nm. P12 possesses a versatile and flexible sample environment system that caters for the diverse experimental needs required to study macromolecular solutions. These include an in-vacuum capillary mode for standard batch sample analyses with robotic sample delivery and for continuous-flow in-line sample purification and characterization, as well as an in-air capillary time-resolved stopped-flow setup. A novel microfluidic centrifugal mixing device (SAXS disc) is developed for a high-throughput screening mode using sub-microlitre sample volumes. Automation is a key feature of P12; it is controlled by a beamline meta server, which coordinates and schedules experiments from either standard or nonstandard operational setups. The integrated SASFLOW pipeline automatically checks for consistency, and processes and analyses the data, providing near real-time assessments of overall parameters and the generation of low-resolution models within minutes of data collection. These advances, combined with a remote access option, allow for rapid high-throughput analysis, as well as time-resolved and screening experiments for novice and expert biological SAXS users.

1 January 2015 in Acta Crystallographica Section D Structural Biology
Verified
Journal Article
Open access
PDF file
ARAdam Round
Adam Round
FFFranck Felisaz
Franck Felisaz
LFLukas Fodinger
Lukas Fodinger
AGAlexandre Gobbo
Alexandre Gobbo
JHJulien Huet
Julien Huet
FCFlorent Cipriani
Florent Cipriani
Small-angle X-ray scattering (SAXS) of macromolecules in solution is in increasing demand by an ever more diverse research community, both academic and industrial. To better serve user needs, and to allow automated and high-throughput operation, a sample changer (BioSAXS Sample Changer) that is able to perform unattended measurements of up to several hundred samples per day has been developed. The Sample Changer is able to handle and expose sample volumes of down to 5 µl with a measurement/cleaning cycle of under 1 min. The samples are stored in standard 96-well plates and the data are collected in a vacuum-mounted capillary with automated positioning of the solution in the X-ray beam. Fast and efficient capillary cleaning avoids cross-contamination and ensures reproducibility of the measurements. Independent temperature control for the well storage and for the measurement capillary allows the samples to be kept cool while still collecting data at physiological temperatures. The Sample Changer has been installed at three major third-generation synchrotrons: on the BM29 beamline at the European Synchrotron Radiation Facility (ESRF), the P12 beamline at the PETRA-III synchrotron (EMBL@PETRA-III) and the I22/B21 beamlines at Diamond Light Source, with the latter being the first commercial unit supplied by Bruker ASC.

6 December 2023 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Open access
JPJulian Philipp
Julian Philipp
ADAleksandra Dabkowska
Aleksandra Dabkowska
ARAnita Reiser
Anita Reiser
KFKilian Frank
Kilian Frank
RKRafał Krzysztoń
Rafał Krzysztoń
JRJoachim O. Rädler
Joachim O. Rädler
Lipid nanoparticles (LNPs) are advanced core-shell particles for messenger RNA (mRNA) based therapies that are made of polyethylene glycol (PEG) lipid, distearoylphosphatidylcholine (DSPC), cationic ionizable lipid (CIL), cholesterol (chol), and mRNA. Yet the mechanism of pH-dependent response that is believed to cause endosomal release of LNPs is not well understood. Here, we show that eGFP (enhanced green fluorescent protein) protein expression in the mouse liver mediated by the ionizable lipids DLin-MC3-DMA (MC3), DLin-KC2-DMA (KC2), and DLinDMA (DD) ranks MC3 ≥ KC2 > DD despite similar delivery of mRNA per cell in all cell fractions isolated. We hypothesize that the three CIL-LNPs react differently to pH changes and hence study the structure of CIL/chol bulk phases in water. Using synchrotron X-ray scattering a sequence of ordered CIL/chol mesophases with lowering pH values are observed. These phases show isotropic inverse micellar, cubic Fd3m inverse micellar, inverse hexagonal H II and bicontinuous cubic Pn3m symmetry. If polyadenylic acid, as mRNA surrogate, is added to CIL/chol, excess lipid coexists with a condensed nucleic acid lipid H II c phase. The next-neighbor distance in the excess phase shows a discontinuity at the Fd3m inverse micellar to inverse hexagonal H II transition occurring at pH 6 with distinctly larger spacing and hydration for DD vs. MC3 and KC2. In mRNA LNPs, DD showed larger internal spacing, as well as retarded onset and reduced level of DD-LNP-mediated eGFP expression in vitro compared to MC3 and KC2. Our data suggest that the pH-driven Fd3m- H II transition in bulk phases is a hallmark of CIL-specific differences in mRNA LNP efficacy.

4 February 2015 in Journal of Synchrotron Radiation
Verified
Journal Article
Closed access
PDF file
CJCy M. Jeffries
Cy M. Jeffries
MGMelissa A. Graewert
Melissa A. Graewert
DSDmitri I. Svergun
Dmitri I. Svergun
CBClement Blanchet
Clement Blanchet

5 September 2020 in Cells
Verified
Journal Article
Open access
PDF file
CSChristian Siewert
Christian Siewert
Heinrich HaasHeinrich Haas
Heinrich Haas
VCVera Cornet
Vera Cornet
SNSara S. Nogueira
Sara S. Nogueira
TNThomas Nawroth
Thomas Nawroth
Peter LangguthPeter Langguth
Peter Langguth
Hybrid nanoparticles from lipidic and polymeric components were assembled to serve as vehicles for the transfection of messenger RNA (mRNA) using different portions of the cationic lipid DOTAP (1,2-Dioleoyl-3-trimethylammonium-propane) and the cationic biopolymer protamine as model systems. Two different sequential assembly approaches in comparison with a direct single-step protocol were applied, and molecular organization in correlation with biological activity of the resulting nanoparticle systems was investigated. Differences in the structure of the nanoparticles were revealed by thorough physicochemical characterization including small angle neutron scattering (SANS), small angle X-ray scattering (SAXS), and cryogenic transmission electron microscopy (cryo-TEM). All hybrid systems, combining lipid and polymer, displayed significantly increased transfection in comparison to lipid/mRNA and polymer/mRNA particles alone. For the hybrid nanoparticles, characteristic differences regarding the internal organization, release characteristics, and activity were determined depending on the assembly route. The systems with the highest transfection efficacy were characterized by a heterogenous internal organization, accompanied by facilitated release. Such a system could be best obtained by the single step protocol, starting with a lipid and polymer mixture for nanoparticle formation.

27 October 2020 in Crystals
Verified
Journal Article
Open access
PDF file
MGMelissa Ann Graewert
Melissa Ann Graewert
SVStefano Da Vela
Stefano Da Vela
TGTobias W. Gräwert
Tobias W. Gräwert
DMDmitry Molodenskiy
Dmitry Molodenskiy
CBClement Blanchet
Clement Blanchet
CJCy M. Jeffries
Cy M. Jeffries
We describe the updated size-exclusion chromatography small angle X-ray scattering (SEC-SAXS) set-up used at the P12 bioSAXS beam line of the European Molecular Biology Laboratory (EMBL) at the PETRAIII synchrotron, DESY Hamburg (Germany). The addition of size exclusion chromatography (SEC) directly on-line to the SAXS capillary has become a well-established approach to reduce the effects of the sample heterogeneity on the SAXS measurements. The additional use of multi-angle laser light scattering (MALLS), UV absorption spectroscopy, refractive index (RI), and quasi-elastic light scattering (QELS) in parallel to the SAXS measurements enables independent molecular weight validation and hydrodynamic radius estimates. This allows one to address sample monodispersity as well as conformational heterogeneity. The benefits of the current SEC-SAXS set-up are demonstrated on a set of selected standard proteins. The processed SEC-SAXS data and models are provided in the Small Angle Scattering Biological Data Bank (SASBDB) and are labeled as “bench-marked” datasets that include the unsubtracted data frames spanning the respective SEC elution profiles and corresponding MALLS-UV-RI-QELS data. These entries provide method developers with datasets suitable for testing purposes, in addition to an educational resource for SAS data analysis and modeling.