Iatrogenic perforations that occur during the endoscopic procedures are generally surgically managed, even if some authors prefer a non‐surgical approach in selected cases. The endoscopic application of metallic clips has been widely used in the gastrointestinal (GI) tract for hemostasis and also for marking lesions. Since 1993 several series of endoscopic perforations treated with endoclips have been described in the literature. In this review we offer a descriptive analysis of the reported cases of the acute iatrogenic perforation, describing the closure of different perforations occurring in the GI tract, treated with metallic clips.
Background It is unknown whether there is an advantage to using the wet-suction or slow-pull technique during endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) with new-generation needles. We aimed to compare the performance of each technique in EUS-FNB. Methods This was a multicenter, randomized, single-blind, crossover trial including patients with solid lesions of ≥ 1 cm. Four needle passes with 22 G fork-tip or Franseen-type needles were performed, alternating the wet-suction and slow-pull techniques in a randomized order. The primary outcome was the histological yield (samples containing an intact piece of tissue of at least 550 μm). Secondary end points were sample quality (tissue integrity and blood contamination), diagnostic accuracy, and adequate tumor fraction. Results Overall, 210 patients with 146 pancreatic and 64 nonpancreatic lesions were analyzed. A tissue core was retrieved in 150 (71.4 %) and 129 (61.4 %) cases using the wet-suction and the slow-pull techniques, respectively (P = 0.03). The mean tissue integrity score was higher using wet suction (P = 0.02), as was the blood contamination of samples (P < 0.001). In the two subgroups of pancreatic and nonpancreatic lesions, tissue core rate and tissue integrity score were not statistically different using the two techniques, but blood contamination was higher with wet suction. Diagnostic accuracy and tumor fraction did not differ between the two techniques. Conclusion Overall, the wet-suction technique in EUS-FNB resulted in a higher tissue core procurement rate compared with the slow-pull method. Diagnostic accuracy and the rate of samples with adequate tumor fraction were similar between the two techniques.
Background The advantage of using the macroscopic on-site evaluation (MOSE) technique during endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) performed with 22G Franseen needles has not been investigated. We aimed to compare EUS-FNB with MOSE vs. EUS-FNB performed with three needle passes. Methods This randomized trial involved 10 Italian referral centers. Consecutive patients referred for EUS-FNB of pancreatic or nonpancreatic solid lesions were included in the study and randomized to the two groups. MOSE was performed by gross visualization of the collected material by the endoscopists and considered adequate when a white/yellowish aggregate core longer than 10 mm was retrieved. The primary outcome was diagnostic accuracy. Secondary outcomes were specimen adequacy, number of needle passes, and safety. Results 370 patients with 234 pancreatic lesions (63.2 %) and 136 nonpancreatic lesions (36.8 %) were randomized (190 EUS-FNB with MOSE and 180 with standard EUS-FNB). No statistically significant differences were found between EUS-FNB with MOSE and conventional EUS-FNB in terms of diagnostic accuracy (90.0 % [95 %CI 84.8 %–93.9 %] vs. 87.8 % [95 %CI 82.1 %–92.2 %]; P = 0.49), sample adequacy (93.1 % [95 %CI 88.6 %–96.3 %] vs. 95.5 % [95 %CI 91.4 %–98 %]; P = 0.31), and rate of adverse events (2.6 % vs. 1.1 %; P = 0.28). The median number of passes was significantly lower in the EUS-FNB with MOSE group (1 vs. 3; P < 0.001). Conclusions The accuracy of EUS-FNB with MOSE is noninferior to that of EUS-FNB with three needle passes. MOSE reliably assesses sample adequacy and reduces the number of needle passes required to obtain the diagnosis with a 22G Franseen needle.
1 January 2016 in World Journal of Gastrointestinal Endoscopy
Biliary and pancreatic stenting: Devices and insertion techniques in therapeutic endoscopic retrograde cholangiopancreatography and endoscopic ultrasonography
1 January 2016 in World Journal of Gastrointestinal Surgery
Over-the-scope clips in the treatment of gastrointestinal tract iatrogenic perforation: A multicenter retrospective study and a classification of gastrointestinal tract perforations