Jee Hye Lee

Dr. Jee Hye Lee


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 March 2018 in BMC Ophthalmology
Verified
Journal Article
Open access
PDF file
MCMihyun Choi
Mihyun Choi
MLMarjorie Z. Lazo
Marjorie Z. Lazo
MKMinji Kang
Minji Kang
JLJee Hye Lee
Jee Hye Lee
CJChoun-Ki Joo
Choun-Ki Joo
The present study aimed to evaluate the degree of anterior capsule contraction (capsulorhexis contraction) with three different single-piece, hydrophilic acrylic intraocular lenses (IOLs). Patients were prospectively randomized to be implanted with one of three types of IOLs during cataract surgery: the Ophtec Precizon (IOL A), the Lucid Korea Microflex (IOL B), and the Carl Zeiss Asphina (IOL C). One week, 2 weeks, and 6 months after surgery, the area of the anterior capsule opening was measured using digital retro-illumination images after dilation of the pupil. The data were then evaluated using POCOman software. The study included 236 eyes of 202 patients. The area of the anterior capsule opening reduced by 3.53 ± 3.31 mm (17.06% ± 15.99%) between 1 week and 2 months post-operatively in the IOL A group, by 0.62 ± 1.32 mm (2.87% ± 6.03%) in the IOL B group, and by 1.09 ± 1.53 mm (4.72% ± 6.10%) in the IOL C group. The IOL B group showed minimal anterior capsule contraction 2 months after surgery (p < 0.001). IOLs with a four-plate haptic design (IOL B) showed more anterior capsular stability than those with a two-loop plate haptic (IOL A) or two-plate haptic (IOL C) design. The number and position of haptics in a capsular bag may affect anterior capsule contraction. We assume that supporting the zonules evenly may play a role in anterior capsular stability. Current Controlled Trials ISRCTN76566080 , Retrospectively registered (Date of registration: 14 Feb 2018).

10 May 2018 in BMC Ophthalmology
Verified
Journal Article
Open access
PDF file
JLJee Hye Lee
Jee Hye Lee
YLYong Eun Lee
Yong Eun Lee
CJChoun-Ki Joo
Choun-Ki Joo
To compare the results of continuous curvilinear capsulorrhexis(CCC) after application of an open ring-shaped guider compared with a free-hand procedure in eyes with cataracts. This study comprised patients undergoing cataract surgery in Seoul St.Mary’s Hospital, The Catholic University of Korea. Eyes were grouped depending on the capsulotomy method; CCC was performed by free-hand procedure on 94 eyes (free-hand group), and it was performed under the guidance after introduction of an open ring-shaped guider on consecutive 89 eyes (guided group). Horizontal and vertical diameter, area and circularity of capsulotomy were measured postoperatively at one day, two months and six months. Differences in parameters and the percentage of ideal capsulorrhexis were analyzed between the two groups. On the first postoperative day, the vertical diameter in the guided group (5.24 ± 0.16 mm) was significantly longer than that of the free-hand group (5.01 ± 0.65 mm, P = 0.019). The area of capsulotomy was larger in the guided group (21.55 ± 0.87 mm2) than that of the free-hand group (20.34 ± 2.96 mm2, P < 0.001). Circularity in the guided group (0.84 ± 0.03), was significantly greater than that of the free-hand group (0.69 ± 0.17, P = 0.036). Ideal capsulorrhexis was obtained in 60 eyes (67%) in the free-hand group and 81 eyes (86%) in the guided group. After introduction of an open ring-shaped guider, CCC became larger and more circular with less anterior capsular contracture. The rate of acquiring ideal capsulorrhexis was higher in the guided group than it was in the free-hand group for six months after surgery.

14 December 2023 in Medicina
Verified
Journal Article
Open access
PDF file
YLYuri Lee
Yuri Lee
JKJae Suk Kim
Jae Suk Kim
BKBum Gi Kim
Bum Gi Kim
JPJae SukKim PhD
Jae SukKim PhD
MKMin Ji Kang
Min Ji Kang
JLJee Hye Lee
Jee Hye Lee
Background and Objectives: Posterior capsular opacification (PCO) is the most common long-term complication of successful cataract surgery and can cause visual impairment. We aimed to investigate the effects of intraocular lens (IOL) characteristics on PCO by comparing the incidence of neodymium-doped yttrium aluminum garnet (Nd:YAG) laser capsulotomy for different types of intraocular lenses. Materials and Methods: A retrospective analysis was performed on 2866 eyes that underwent cataract surgery between January 2010 and December 2017, with at least 5 years of follow-up. The IOLs used for surgery were the hydrophobic lenses SN60WF (Alcon, Fort Worth, TX, USA), ZCB00 (Johnson & Johnson Vision, Santa Ana, CA, USA), and MX60 (Bausch & Lomb, Rochester, NY, USA), and the hydrophilic lens MI60 (Bausch & Lomb, Rochester, NY, USA). We analyzed the incidence of Nd:YAG laser capsulotomy according to the type of IOL used. Results: The incidence of Nd:YAG laser capsulotomy was significantly higher with MI60 lenses (31.70%, 175/552 eyes) compared to SN60WF (7.90%, 113/1431 eyes), ZCB00 (10.06%, 64/636 eyes), and MX60 (10.57%, 13/123 eyes; p < 0.001) lenses. The incidence of Nd:YAG laser capsulotomy was significantly lower with the hydrophobic IOLs (8.68%, 190/2190 eyes) than with the hydrophilic IOL (31.70%, 175/552 eyes; p < 0.001). Over time, the rate of increase in the cumulative number of Nd:YAG laser capsulotomy cases was the highest with MI60. The cumulative rate of Nd:YAG laser capsulotomy during the first 3 years was 4.90% with SN60WF (70/1431 eyes), 6.76% with ZCB00 (43/636 eyes), 8.94% with MX60 (11/123 eyes), and 26.10% with MI60 (144/552 eyes) lenses. Conclusions: The incidence of PCO is influenced by the material of the IOLs. The hydrophilic IOL was associated with a higher rate of Nd:YAG laser capsulotomy than the hydrophobic IOLs, with a shorter time to Nd:YAG laser capsulotomy.

18 May 2022 in Pathogens
Verified
Journal Article
Open access
PDF file
JLJee Hye Lee
Jee Hye Lee
MKMin-Ji Kang
Min-Ji Kang
HSHa-Eun Sim
Ha-Eun Sim
JHJe Hyung Hwang
Je Hyung Hwang
Preservative-free artificial tears eliminate the side effects of preservatives but are prone to microbial contamination. This study evaluates the incidence of microbial contaminations in single-use vials of preservative-free 0.1% hyaluronate artificial tears. Based on what touched the vial tip during its first use, 60 unit-dose vials (0.5 mL) were divided into groups A (no touch, n = 20), B (fingertip, n = 20), and C (lid margin, n = 20). The vials were recapped after the first use, and the residual solution was cultured 24 h later. The solution from 20 aseptically opened and unused vials was also cultured (group D). Microbial contamination rates were compared between the groups using the Fisher’s exact test. Groups B and C contained 45% (9/20) and 10% (2/20) contaminations while groups A and D contained undetected microbial growth. The culture positivity rates were significantly different between groups A and B (p = 0.001) and groups B and C (p = 0.013) but not between groups A and C (p = 0.487). We demonstrate a significantly higher risk of contamination when fingertips touch the vial mouth. Therefore, users should avoid the vial tip touching the fingers or eyelid during instillation to prevent contamination of the eye drops.