Regenerative cooling is of great significance to secure the thermal structure and promote the flight Mach number range of the SCRamjet. Interconnection structure (ICS) plays a key role in improving the coolant flow distribution and heat sink utilization. In this work, the flow and heat transfer behaviors of the hydrocarbon fuel in parallel regenerative cooling channels with ICS are numerically investigated. The ICS improves the flow distribution and alleviates the local heat transfer deterioration. The influences of ICS configuration mainly consist of two aspects: (a). inter-channel pressure communication; (b). transverse mass transfer. The maximum wall temperature falls by 117.48 K/6.96% with the ICS introduced. Different sizes and positions of ICS are also studied. ICS with too small size cannot provide enough space for pressure communication and transverse mass transfer. While ICS with too large size leads to local heat transfer deterioration. The optimal Ф value to achieve the lowest heated wall temperature is Ф = 5 in this work. Regarding the position of ICS, it affects the local heat transfer deterioration through flow distribution and thermal load distribution. Ps = 50% (ICS locates at the middle of the heated section) presents the optimal cooling effect in this work. At last, the ICS configurations are universal to different heat flux distributions. The maximum wall temperature (Case qf2) decreases by 137.72 K/8.15% compared with Case C1 (without ICS).
The growing interest of liquid-fueled detonation engines for the next-generation propulsion applications necessitates extensive understanding of the breakup physics of droplets induced by detonation waves. However, current knowledge of this topic still remains very limited. The breakup dynamics of water droplets induced by detonation waves under varying diameters and Mach numbers were experimentally investigated in the present study. High-speed schlieren imaging was used to capture the detailed breakup process of the droplets. Based on the experimentally observed flow instabilities, the detonation-induced droplet breakup can be classified into two stages dominated by the Kelvin–Helmholtz instability (KHI) and Rayleigh–Taylor instability (RTI), respectively. During the KHI-dominated phase, droplets of different Mach numbers and diameters exhibit nearly identical linear growth in non-dimensional cross-stream diameter with non-dimensional time. For the first time, significant differences in droplet acceleration between detonation waves and shock waves have been reported. The dimensionless droplet acceleration induced by shock waves is 11–17 times greater than that induced by detonation waves. Finally, theoretical analysis and experimental results show that decreasing droplet diameter and increasing Mach number can accelerate the instability development and shorten the absolute breakup time.
In supersonic combustion ramjet (SCRamjet), regenerative cooling channels face challenges from high heat flux and strict fuel quantity constraints. Moreover, the thermal boundary conditions of cooling channels are typically non-uniform, which may induce non-uniform fuel distribution. This can lead to serious waste of fuel cooling capability and even cause over-temperature conditions. To ensure heated wall safety, topological optimization of regenerative cooling channels is urgently needed to improve reasonable flow distribution and efficient utilization of cooling capacity. In this work, a three-layer pseudo-three-dimensional (pseudo-3D) model is developed and validated, accounting for turbulent flow and thermal property variations of hydrocarbon fuel. Topological optimization is further conducted on regenerative cooling channels under uniform and multiple non-uniform heat flux distributions. The three-dimensional (3D) numerical results of topology-optimized channels demonstrate that discrete ribs promote fluid divergence and convergence, enhancing heat transfer and optimizing flow distribution. The maximum wall temperature is reduced by 9.3%, 8.5%, and 13.17%, respectively. The Nusselt number is increased by 42.5%, 41.4%, and 49.3%, respectively. Finally, cylindrical pin-fins are used as basic structural units to construct the topological structure, avoiding unreasonable designs from the topology optimization process. This approach achieves a 6.9% reduction in maximum wall temperature. The research in this paper is expected to further support the optimized design of regenerative cooling channels.
25 April 2023 in Numerical Heat Transfer, Part A: Applications
Hypersonic air-breathing propulsion (>Mach 5) based on scramjet offers new solutions to both the military strike platform and the civil transportation. However, the hypersonic flight seriously challenges the engine thermal protection. One of the key problems is the tricky flow and thermal behaviors of hydrocarbon fuel in regenerative cooling channels under the complex thermal boundaries and channel geometry, which may cause heat transfer deterioration and structure over-temperature. To improve the cooling design, the double-layer regenerative cooling channels are focused and compared with the traditional single-layer channels. The flow and thermal behaviors of hydrocarbon fuel under different cooling configurations are numerically studied. Cooling performance of double-layer channels is superior than single-layer channels. Tw,max falls by 295.2 K/17.7%. Gravity direction and magnitude show negligible influence on the heat transfer. Regarding channel height ratio, H1/H2 = 1.1/1 achieves optimal cooling performance in present conditions. Double-layer-channel scheme presents high practicability in scramjet cooling.
Regenerative cooling is considered promising in the thermal protection of hypersonic propulsion devices such as SCRamjet. However, the heat transfer deterioration (HTD) of hydrocarbon fuel is a severe threat to the thermal structure safety, especially under axially nonuniform heat flux caused by the thermal load difference in different components. In this work, the heat transfer of trans-critical n-decane in a mini-horizontal channel is numerically investigated. The influences of the axially nonuniform heat flux on the heat transfer is focused on. Two types of HTD are recognized and analyzed. The first type of HTD is induced by the near-wall flow acceleration and the local thickening of the viscous sublayer. The second type of HTD is closely related to the expansion of the low thermal conductivity λ and specific heat cp region, which is seriously worsened under axially nonuniform heat flux, especially when the heat flux peak locates where Tw ≥ Tpc. The minimum HTC deteriorates by 40.80% and the Tw_max increases from 857 K to 1071 K by 27.5%. The maximum fluctuation in pressure drop is 6.8% in the variation in heat flux distribution with Φ = 2. This work is expected to offer a reference to the proper match of fuel temperature distribution and the engine heat flux boundary in SCRamjet cooling system design.