Meng Gao

Dr. Meng Gao


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 February 2019 in KSCE Journal of Civil Engineering
Verified
Journal Article
Open access
PDF file
GGGuangyun Gao
Guangyun Gao
MGMeng Gao
Meng Gao
QCQingsheng Chen
Qingsheng Chen
JYJun Yang
Jun Yang
To investigate the vertical bearing behavior of manually excavated large diameter belled concrete piles (LDBCPs), field loading tests were performed on a total of 16 LDBCPs, ranging from 0.8 to 3.5 m in base diameter from 6.1 to 18.0 m in embedment length. The end bearing stratum is sand and gravel. The influence of pile dimensions (i.e., size of enlarged base D, embedment length L, and length-to-diameter ratio L/D) on the vertical bearing behavior of a belled pile is presented and discussed. Comparison is also made of the vertical bearing behavior of a belled pile and of a conventional straight pile under otherwise similar conditions. The results indicate that: 1) The vertical bearing capacity of a belled pile is significantly greater than that of a conventional straight pile provided the debris at the bottom of a belled pile is properly removed; 2) over 65% of the vertical bearing capacity for a belled pile is attributed to the tip resistance (Qe); 3) compared to the contribution of pile length L, increasing enlarged base D is a more effective way to increase the vertical ultimate bearing capacity of a belled pile (Qu); 4) the optimum length-to-enlarged base ratio (L/D) for belled piles to achieve maximum vertical bearing capacity is around 3.2.

24 September 2023 in Soil Dynamics and Earthquake Engineering
Verified
Journal Article
Closed access
YWYing Wang
Ying Wang
CZCaiqing Zhao
Caiqing Zhao
MGMeng Gao
Meng Gao
HWHaiping Wang
Haiping Wang

19 March 2021 in Geotechnical and Geological Engineering
Verified
Journal Article
Closed access
PDF file
MGMeng Gao
Meng Gao
YSY. S. Song
Y. S. Song
YWY. Wang
Y. Wang
QCQ. S. Chen
Q. S. Chen

27 September 2025 in Earthquake Engineering and Engineering Vibration
Verified
Journal Article
Closed access
PDF file
MGMeng Gao
Meng Gao
ZTZhonghai Tang
Zhonghai Tang
QCQingsheng Chen
Qingsheng Chen
LXLihui Xu
Lihui Xu
GGGuangyun Gao
Guangyun Gao

2 May 2024 in Soil Dynamics and Earthquake Engineering
Verified
Journal Article
Closed access
MGMeng Gao
Meng Gao
LFLuao Fan
Luao Fan
GGGuangyun Gao
Guangyun Gao

1 February 2025 in Mechanics of Solids
Verified
Journal Article
Closed access
PDF file
TZTang Zhonghai
Tang Zhonghai
MGMeng Gao
Meng Gao
XLXu Lihui
Xu Lihui
The frequency components of artificial vibration sources are relatively complex, with distributions in low, medium, and high frequencies. However, previous studies have shown that traditional wave barriers only have good isolation effects on low-frequency vibrations, which constrains the utilisation of WIB in engineering vibration mitigation. Therefore, a metamaterial wave impeding block (MWIB) has been presented according to photonic crystal theory. The characteristic of band gap in the MWIB was explored using theoretical and finite element method (FEM), and the impact of structure and material properties on bandwidth characteristics was also examined. Finally, a three-dimensional analytical model of the MWIB-soil structure was developed, as well as its vibration isolation efficacy of the MWIB under harmonic loading was evaluated., and contrasted to the homogeneous concrete WIB. The findings indicate that the MWIB with finite and infinite periodic structures has consistent attenuation domains and bandgap range. The peak amplitude reduction of the vibration’s attenuation region can attain 43 dB, which is higher than that of traditional wave impeding block(WIB). The MWIB shows clear bandgap properties, and its bandgap range are closely related to the periodic constant, geometric parameters, and material parameters and are a function of them. The required bandgap for engineering vibration isolation can be obtained by adjusting these parameters. The vibration isolation efficacy with the MWIB is markedly enhanced in comparison to the WIB.