To investigate the vertical bearing behavior of manually excavated large diameter belled concrete piles (LDBCPs), field loading tests were performed on a total of 16 LDBCPs, ranging from 0.8 to 3.5 m in base diameter from 6.1 to 18.0 m in embedment length. The end bearing stratum is sand and gravel. The influence of pile dimensions (i.e., size of enlarged base D, embedment length L, and length-to-diameter ratio L/D) on the vertical bearing behavior of a belled pile is presented and discussed. Comparison is also made of the vertical bearing behavior of a belled pile and of a conventional straight pile under otherwise similar conditions. The results indicate that: 1) The vertical bearing capacity of a belled pile is significantly greater than that of a conventional straight pile provided the debris at the bottom of a belled pile is properly removed; 2) over 65% of the vertical bearing capacity for a belled pile is attributed to the tip resistance (Qe); 3) compared to the contribution of pile length L, increasing enlarged base D is a more effective way to increase the vertical ultimate bearing capacity of a belled pile (Qu); 4) the optimum length-to-enlarged base ratio (L/D) for belled piles to achieve maximum vertical bearing capacity is around 3.2.
24 September 2023 in Soil Dynamics and Earthquake Engineering
The frequency components of artificial vibration sources are relatively complex, with distributions in low, medium, and high frequencies. However, previous studies have shown that traditional wave barriers only have good isolation effects on low-frequency vibrations, which constrains the utilisation of WIB in engineering vibration mitigation. Therefore, a metamaterial wave impeding block (MWIB) has been presented according to photonic crystal theory. The characteristic of band gap in the MWIB was explored using theoretical and finite element method (FEM), and the impact of structure and material properties on bandwidth characteristics was also examined. Finally, a three-dimensional analytical model of the MWIB-soil structure was developed, as well as its vibration isolation efficacy of the MWIB under harmonic loading was evaluated., and contrasted to the homogeneous concrete WIB. The findings indicate that the MWIB with finite and infinite periodic structures has consistent attenuation domains and bandgap range. The peak amplitude reduction of the vibration’s attenuation region can attain 43 dB, which is higher than that of traditional wave impeding block(WIB). The MWIB shows clear bandgap properties, and its bandgap range are closely related to the periodic constant, geometric parameters, and material parameters and are a function of them. The required bandgap for engineering vibration isolation can be obtained by adjusting these parameters. The vibration isolation efficacy with the MWIB is markedly enhanced in comparison to the WIB.