Mingyu Lim

Mr. Mingyu Lim


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 July 2022 in Energies
Verified
Journal Article
Open access
PDF file
재정재범 정
재범 정
MLMingyu Lim
Mingyu Lim
JKJin-Yong Kim
Jin-Yong Kim
BHByeong-Gill Han
Byeong-Gill Han
BKByungki Kim
Byungki Kim
Dae-Seok RhoDae-Seok Rho
Dae-Seok Rho
In recent years, the demand for medium and large secondary batteries in EV (electric vehicle) and ESS (energy storage systems) applications has been rapidly increasing worldwide, and accordingly, the market size is increasing exponentially. However, the recent fire accidents related to secondary batteries for EVs and ESS are having a negative impact on the battery market. Therefore, this paper implements an accident simulation device to perform an external short-circuit test, one of the typical safety tests for NMC-series prismatic and pouch-type batteries that are widely used among battery cells used in medium and large secondary batteries. The implemented accident simulation device for the external short-circuit test is composed of short-circuit resistance, measuring device, control device, etc., and is configured to analyze external short-circuit characteristics according to various test conditions. Based on this, an external short-circuit test according to the type, short-circuit resistance and SOC (states of charge) of the lithium-ion battery was performed to confirm the current and temperature characteristics according to each condition. As a result of performing an external short-circuit test for each protection device in the battery module and preprocessing temperature, it is certain that the module fuse operates over 120 times faster than the cell fuse based on the same SOC conditions, and the quantity of electric charge in the module fuse is over 110 times smaller than of the cell fuse in the case of a short-circuit fault. It is also found that the highest and lowest preprocessing temperatures are considered to be severe conditions. Based on the proposed mechanism of an external short circuit in a Li-ion battery and the test device for the external short circuit, it is confirmed that this paper can contribute to the safety assessment of Li-ion battery-based ESS.

27 July 2023 in Energies
Verified
Journal Article
Open access
PDF file
MLMingyu Lim
Mingyu Lim
재정재범 정
재범 정
NKNam-Hyun Kim
Nam-Hyun Kim
JI MYUNG KIMJI MYUNG KIM
JI MYUNG KIM
JSJian Shen
Jian Shen
Dae-Seok RhoDae-Seok Rho
Dae-Seok Rho
The number of used batteries is expected to dramatically increase in the near future due to the expansion of the electric vehicle (EV) market globally. Accordingly, the Korean government has improved the supporting structures for the recycling system for used batteries, and in particular, in the field of repurposing, various studies are being conducted with a focus on effective evaluation methods that can secure the performance and safety of batteries after use. The repurposing of used batteries is mostly adapted in the field of energy storage systems for normally used EV batteries and a total inspection before repurposing is required due to battery characteristics that can vary depending on the operational environments of and accidents involving medium- and large-sized batteries for EVs and energy storage systems (ESSs) that have been occurring continuously for the past few years. Therefore, this paper investigates the operating mechanisms of the internal resistance test method and implements a test device for middle- and large-sized cells and packs. Based on the proposed test method, the internal resistance of nickel manganese cobalt (NMC)-type commercial large batteries is analyzed according to the SOC (state of charge), SOH (state of health), ambient temperature, and connection degradation of batteries. The distribution degrees of the alternative current (AC) internal resistance (IR) and direct current (DC) internal resistance (IR) measurement methods under state of health (SOH) test conditions are about 7% and 50%. It was found that the DC IR measurement method is more effective in diagnosing battery cell degradation. The distribution degree of DC IR measurements for the degraded connection condition shows an increase of less than 1% regardless of the state of charge (SOC), while the distribution degree of the AC IR measurements shows an increase of up to 319%, indicating that the AC IR method is more effective than the DC IR method in identifying connection degradation. It is confirmed that the proposed method is effective in internal resistance measurement and safety evaluations for the repurposing of batteries.