Chao Chen

Dr. Chao Chen

Beijing Institute of Technology, Beijing, China
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 January 2025 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
Chao ChenChao Chen
Chao Chen
Xiaoyong SunXiaoyong Sun
Xiaoyong Sun
ZCZhen Chen
Zhen Chen
XLXiangdong Liu
Xiangdong Liu
Z. Q. ZhuZ. Q. Zhu
Z. Q. Zhu
XLXiaozhong Liao
Xiaozhong Liao
Multiphase permanent magnet synchronous motors (PMSMs) driven by the current source inverters (CSIs) are widely used in safety-critical applications, due to their fault-tolerant capability and high torque/power density. Nevertheless, the fault-tolerant field-oriented control method based on reduced order transformation matrices for addressing the adjacent double-phase open-circuit fault (ADP-OCF) in the CSI has not yet been established. Moreover, the influence of faulty phase winding currents has not been analyzed and suppressed. Hence, this article develops a fault-tolerant control approach that includes compensation for faulty phase winding currents in the case of ADP-OCF in the CSI. First, the optimized fault-tolerant winding currents are derived. Subsequently, the decoupled mathematical model and fault-tolerant space-vector-pulsewidth-modulation (PWM) strategy are established, and finally the fault-tolerant control is achieved. The effectiveness of the proposed fault-tolerant control scheme has been validated in the experimental results. Additionally, the utilization of compensating for faulty phase winding currents can lead to a further reduction in electromagnetic torque ripple by 19.32%.

16 June 2022 in Energies
Verified
Journal Article
Open access
PDF file
Chao ChenChao Chen
Chao Chen
ZCZhen Chen
Zhen Chen
CGCongzhe Gao
Congzhe Gao
JZJing Zhao
Jing Zhao
XLXiangdong Liu
Xiangdong Liu
Xiaoyong SunXiaoyong Sun
Xiaoyong Sun
Among the existing harmonic current suppression methods, it is difficult and complicated to suppress any nth harmonic current accurately for multi-phase permanent magnet synchronous motors (PMSMs). To solve this problem, this paper takes a five-phase dual-rotor PMSM fed with a current source inverter (CSI) as an example, and proposes an nth harmonic current suppression method based on the impulse current PWM algorithm. Firstly, the analysis is conducted and presented for the nth harmonic current in the mth harmonic space. Then, based on the Sliding Discrete Fourier Transformation (SDFT), a low-pass filter (LPF) named SDFT-LPF is designed. Additionally, the impulse current PWM technique for the five-phase CSI is realized. In this paper, the experiments have confirmed that the SDFT-LPF has good filter performance. Compared with the SVPWM, the impulse current PWM technique has the same DC-link current utilization rate, but it is easier to implement. Moreover, the proposed harmonic current control method can accurately control any nth harmonic current without changing the PWM technique, which has significantly reduced the complexity of the harmonic current control. Additionally, the proposed scheme is easy to implement and can be directly extended to the multiple harmonic current’s control.

30 January 2024 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
Chao ChenChao Chen
Chao Chen
Xiaoyong SunXiaoyong Sun
Xiaoyong Sun
Z. Q. ZhuZ. Q. Zhu
Z. Q. Zhu
ZCZhen Chen
Zhen Chen
XLXiangdong Liu
Xiangdong Liu
Due to manufacturing imperfections and assembly tolerances (MIAT), the actual motor inevitably deviates from the desired motor, which may significantly degrade its performance. To ease the influence of MIAT, researchers have studied both motor design and compensation control methods. Compared with the motor design method, compensation control is more cost-effective and flexible but has not been well investigated, especially for motors experiencing asymmetric magnetomotive force (AMMF) due to MIAT. The main purpose of this paper is to suppress the torque ripple for permanent magnet synchronous motor under AMMF caused by MIAT using the compensation control method. This paper firstly analyzes the influence of AMMF on electromagnetic torque performance, then derives the compensation currents for torque ripple suppression. Subsequently, a modified field-oriented-control is established. Moreover, it is found that MIAT can cause neutral voltage oscillation, which significantly affects the current tracking performance. Therefore, a novel space-vector-pulse-width-modulation is proposed to ease the influence of neutral voltage oscillation. The experiments confirmed that the proposed method can reduce the torque ripple by 87.8% and 80.8% during speed acceleration and steady state, respectively. Furthermore, this method has the advantages of better dynamic performance, improved frequency spectrum performance, and higher motor efficiency at high speeds.

11 October 2024 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
Chao ChenChao Chen
Chao Chen
ZCZhen Chen
Zhen Chen
Xiaoyong SunXiaoyong Sun
Xiaoyong Sun
XLXiangdong Liu
Xiangdong Liu
Z. Q. ZhuZ. Q. Zhu
Z. Q. Zhu
Due to system faults, manufacturing imperfections, assembly tolerances, and operational conditions, the filter capacitors of current-source inverters (CSIs) for permanent magnet synchronous motor drives may be asymmetric in real systems, which results in significant torque ripples. To deal with this issue, this article first studies the influence of asymmetric capacitive filters on torque ripples and then proposes three compensation control schemes. Based on the phasor method, the motor currents under asymmetric capacitive filters are first obtained. Then, the torque ripples can be reduced by eliminating the negative-sequence currents (NSCs), which can be achieved by PI controller (NSC-PI), the calculating compensation matrices (NSC-CM-Calculation), and the measuring compensation matrices (NSC-CM-Measured). The control scheme based on NSC-CM-Measured has the best compensation performance among these three methods. However, it requires the measurement of compensation coefficients and d- and q-Axis currents caused by back electromotive forces (back EMFs). It shows that the control scheme based on NSC-CM-Calculation has good compensation performance and fast dynamic performance and can be extended to other asymmetric conditions easily, such as open-circuit filter capacitor conditions. Finally, the experimental results have verified the effectiveness of the proposed compensation schemes.

1 April 2023
Verified
Book Chapter
Closed access
PDF file
Chao ChenChao Chen
Chao Chen
ZCZhen Chen
Zhen Chen
YLYan Li
Yan Li
XLXiongdong Liu
Xiongdong Liu
Youguang GuoYouguang Guo
Youguang Guo

15 December 2025 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
XSXiaoyong Sun
Xiaoyong Sun
WZWenzhe Zhang
Wenzhe Zhang
ZCZhen Chen
Zhen Chen
Chao ChenChao Chen
Chao Chen
RSRuyu Shang
Ruyu Shang
XLXiangdong Liu
Xiangdong Liu
Five-phase permanent magnet machines with current source inverters are preferred for safety critical areas, including aerospace and military industries, owing to superior torque density and robust fault tolerance. Despite the advantages, multi-phase machines are not immune to faults, particularly for the inverters due to potential power switches failures. However, in such systems, there has been no research on single-phase and non-adjacent two-phase open-circuit faults of current-source inverters when the non-zero faulty phase winding current is considered. Therefore, this paper analyses and develops a fault-tolerant control strategy with faulty phase winding current compensation to manage the faults. Firstly, the faulty phase winding current model is established, and the fault-tolerant currents are subsequently derived. Then, a reduced-order decoupled mathematical machine model is proposed, and space current vector pulse width modulation methods are introduced for each fault case. Finally, the effectiveness of the control strategy is validated by experimental results. Under single-phase and non-adjacent two-phase open-circuit faults of the inverter, the fault-tolerant strategy with faulty phase winding current compensation can reduce the torque ripple by 14.98% and 23.21% respectively compared with not adopting it.