Uǧur Atikol

Dr. Uǧur Atikol


Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2015 in Journal of Solar Energy Engineering
Verified
Journal Article
Closed access
PDF file
Sarvenaz SobhansarbandiSarvenaz Sobhansarbandi
Sarvenaz Sobhansarbandi
Uǧur AtikolUǧur Atikol
Uǧur Atikol
There is a growing interest in using solar energy in underfloor heating systems. However, the large areas required for the installation of solar thermal collector's array can be discouraging, especially in the apartment buildings where the apartment's roof is a common area. The objective of this study is to investigate the possibility of using compound parabolic concentrating (CPC) solar collectors instead of the commonly used flat-plate collectors (FPCs) in such systems. It is aimed to explore the feasibility of area reduction required by the collectors. Second, the temperature profiles of circulating water loop and the concrete slabs are sought to be examined. The system consists of solar thermal collectors, a storage tank, and circulation of water to transport the heat to four similar floor slabs. The CPC collector outlet fluid's temperature can reach a maximum of 95 °C, compared to 70 °C obtained from the FPCs. The results from the simulations show that a 2 m2 CPC collector array can perform satisfactorily to match the job of an 8 m2 FPC array, obtaining the same required circulating water's temperature in the slabs.

28 June 2017 in International Journal of Engineering Technologies IJET
Verified
Journal Article
Open access
PDF file
CACenker Aktemur
Cenker Aktemur
Uǧur AtikolUǧur Atikol
Uǧur Atikol
Thermal insulation improves the strength and longevity of buildings by reducing energy consumption, and as a related result, improved energy use. The selection of insulation material is governed by important parameters, including the average outdoor air temperature, the thermal conductivity of the buildings and the cost of the insulation material. Increases in the thickness of the insulation material will gradually decrease the energy consumption for heating; however, the insulation thickness has an optimum value that minimises the total investment cost, and determination of this optimum value is critical for economic analysis. In this paper, a life-cycle cost analysis is presented to show the optimum insulation thickness, energy savings over a lifetime of 15 years and payback periods for six different fuels and insulation materials for four cities in Turkey selected from climate regions identified by the Turkish Thermal Insulation Standard (TS 825). Muğla (1st region), Kocaeli (2nd region), Ankara (3rd region) and Ardahan (4th region) were selected for analysis of a sandwich-type wall constructed from the following six insulation materials: extruded polystyrene, expanded polystyrene, glass wool, rock wool, polyisocyanurate and polyurethane. The calculations were also made on the basis of six different fuels, such as motorin, natural gas, propane (LPG), electricity, coal (imported), and fuel-oil No. 4. As a consequence, results demonstated that the optimum insulation thickness vary between 2.8 cm and 45.1 cm, with energy savings between 16.4 ₺ /m2 and 479 ₺ /m2, and payback periods fluctuating between 0.078 and 0.860 years, depending on the city, the insulation material, and the cost of fuel.

22 February 2013 in International Journal of Energy Research
Verified
Journal Article
Closed access
PDF file
Uǧur AtikolUǧur Atikol
Uǧur Atikol
SAS. Abbasoglu
S. Abbasoglu
RNRaheleh Nowzari
Raheleh Nowzari
In many countries, although solar energy is plentiful, due to technical and economic issues, micro-scale solar energy technologies have not properly found their places in the market. The present work demonstrates the convenience of employing economic feasibility assessments together with engineering analyses before applying solar strategies during the design stages, in order to convince house owners that these solar technologies can be economically viable. In a case study, this approach is tested for a real house project developed in North Cyprus (NC) in which solar energy applications for electricity generation, hot water preparation, space heating and passive cooling are investigated. It is reported that grid-connected photovoltaic (PV) systems would be economically feasible with savings-to-investment ratio (SIR) values of 2.9 to 3.4. A thermal performance analysis is carried out for a thermal storage wall (TSW) together with a direct solar gain (DSG) window in the living room. It is discovered that the temperature range of the living room was within 18–22 °C throughout the majority of winter days. This application is also proved to be economically feasible with an SIR of 1.3, compared to installing an 18,000 Btu/h heat pump. It is determined that both locally produced solar water heaters and imported solar water heaters (ISWHs) are economically viable compared to using a 3-kW storage-type electric water heater. Their SIR values are estimated to be 7.5 and 3.7, respectively. A solar-assisted stack-effect ventilation (SEV) system is verified to have techno-economic feasibility and is also useful in concealing the unattractive cold and hot water storage tanks on the roof. The prospective house owner decides to invest 3840 EUR in installing a grid-connected PV system of 1 kWp, an ISWH, a DSG window, building a TSW for space heating and a SEV system with an overall SIR value of 3.2. This procedure can be developed into a government policy where all these assessments are made mandatory to increase the awareness of the home builders before they make their decisions about the final designs of their houses. The present work demonstrates the convenience of employing economic feasibility assessments together with engineering analyses before applying solar strategies during the design stages, in order to convince house owners that these solar technologies can be economically viable. In a case study, this approach is tested for a real house project developed in NC in which solar energy applications for electricity generation, hot water preparation, space heating and passive cooling are investigated. Copyright © 2013 John Wiley & Sons, Ltd.

1 October 2003 in Energy
Verified
Journal Article
Closed access
Uǧur AtikolUǧur Atikol
Uǧur Atikol
HGH. Güven
H. Güven