Cora Drenkhahn

Ms. Cora Drenkhahn

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 June 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
KVKai Vogl
Kai Vogl
JIJosef Ingenerf
Josef Ingenerf
JKJan Kramer
Jan Kramer
CCChristine Chantraine
Christine Chantraine
CDCora Drenkhahn
Cora Drenkhahn
The coding system Unified Code for Units of Measure (UCUM) serves the unambiguous electronic communication of physical quantities and their measurements and has faced a slow uptake. Despite being closely related to popular healthcare standards such as LOINC, laboratories still majorly report results using proprietary unit terms. Currently available methods helping users create mappings between their units and UCUM are not flexible and automated enough to be of great use in trying to remedy this. We propose the “LOINC to UCUM Mapping Assistant” (LUMA) as a tool able to overcome the drawbacks of existing approaches while being more accessible even to inexperienced users. By mapping LOINC’s Property axis to representations within UCUM reflecting its semantics, we were able to formalize the association between the two. An HL7 FHIR back-end provides LUMA with UCUM unit recommendations sourced from existing lookup tables simply by providing it with a LOINC code. Additionally, the mappings users created may be used to perform unit conversions from proprietary units to UCUM. The tool was evaluated with five participants from the LADR laboratory network in Germany, who valued the streamlined approach to creating the mappings and particularly emphasized the utility of being able to perform unit conversions within the tool.

1 January 2020
Verified
Book Chapter
Open access
PDF file
CDCora Drenkhahn
Cora Drenkhahn
IJIngenerf Josef
Ingenerf Josef
To unambiguously encode the semantic meaning of laboratory tests, the LOINC terminology is widely used. With regard to the constantly changing and diverse requirements of the laboratory domain, LOINC's long-established content model and related publications are reviewed conjointly, revealing some obstacles for flexible adaptation in terms of new or varying application needs as well as issues regarding the comprehensive reusability of lab data. In a concise overview, four specific limitations are identified that require adaptation or the usage of other terminologies.

16 May 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
CDCora Drenkhahn
Cora Drenkhahn
TOTessa Ohlsen
Tessa Ohlsen
JWJoshua Philip Wiedekopf
Joshua Philip Wiedekopf
JIJosef Ingenerf
Josef Ingenerf
Expressive clinical terminologies are of utmost importance for achieving a semantically interoperable data exchange and reuse in healthcare. SNOMED CT, widely respected as the most comprehensive terminology in medicine, provides formal concept definitions based on description logic which not only allows for advanced querying of SNOMED-CT-coded data but also for flexibly augmenting its 350,000 concepts by allowing a controlled combination of these. This ability for postcoordination largely increases the expressivity of the terminology but correlates with an intrinsic complexity. Complicated by the current lack of tooling support, postcoordination is widely either ignored or applied in an error-prone way. To help facilitate the adoption of postcoordination, we implemented a web application that guides users through the creation of postcoordinated expressions (PCEs) while ensuring adherence to syntactic and semantic constraints. Our approach was largely facilitated by making use of the extensive SNOMED CT specifications as well as advanced HL7 FHIR Terminology Services. Qualitative evaluations confirmed the usability of the developed application and the correctness of the PCEs created with it.

17 September 2024 in JMIR Medical Informatics
Verified
Journal Article
Open access
TOTessa Ohlsen
Tessa Ohlsen
JIJosef Ingenerf
Josef Ingenerf
AEAndrea Essenwanger
Andrea Essenwanger
CDCora Drenkhahn
Cora Drenkhahn
Background: To ensure interoperability, both structural and semantic standards must be followed. For exchanging medical data between information systems, the structural standard FHIR (Fast Healthcare Interoperability Resources) has recently gained popularity. Regarding semantic interoperability, the reference terminology SNOMED Clinical Terms (SNOMED CT), as a semantic standard, allows for postcoordination, offering advantages over many other vocabularies. These postcoordinated expressions (PCEs) make SNOMED CT an expressive and flexible interlingua, allowing for precise coding of medical facts. However, this comes at the cost of increased complexity, as well as challenges in storage and processing. Additionally, the boundary between semantic (terminology) and structural (information model) standards becomes blurred, leading to what is known as the TermInfo problem. Although often viewed critically, the TermInfo overlap can also be explored for its potential benefits, such as enabling flexible transformation of parts of PCEs. Objective: In this paper, an alternative solution for storing PCEs is presented, which involves combining them with the FHIR data model. Ultimately, all components of a PCE should be expressible solely through precoordinated concepts that are linked to the appropriate elements of the information model. Methods: The approach involves storing PCEs decomposed into their components in alignment with FHIR resources. By utilizing the Web Ontology Language (OWL) to generate an OWL ClassExpression, and combining it with an external reasoner and semantic similarity measures, a precoordinated SNOMED CT concept that most accurately describes the PCE is identified as a Superconcept. In addition, the nonmatching attribute relationships between the Superconcept and the PCE are identified as the “Delta.” Once SNOMED CT attributes are manually mapped to FHIR elements, FHIRPath expressions can be defined for both the Superconcept and the Delta, allowing the identified precoordinated codes to be stored within FHIR resources. Results: A web application called PCEtoFHIR was developed to implement this approach. In a validation process with 600 randomly selected precoordinated concepts, the formal correctness of the generated OWL ClassExpressions was verified. Additionally, 33 PCEs were used for two separate validation tests. Based on these validations, it was demonstrated that a previously proposed semantic similarity calculation is suitable for determining the Superconcept. Additionally, the 33 PCEs were used to confirm the correct functioning of the entire approach. Furthermore, the FHIR StructureMaps were reviewed and deemed meaningful by FHIR experts. Conclusions: PCEtoFHIR offers services to decompose PCEs for storage within FHIR resources. When creating structure mappings for specific subdomains of SNOMED CT concepts (eg, allergies) to desired FHIR profiles, the use of SNOMED CT Expression Templates has proven highly effective. Domain experts can create templates with appropriate mappings, which can then be easily reused in a constrained manner by end users.

1 January 2019
Verified
Book Chapter
Open access
PDF file
CDCora Drenkhahn
Cora Drenkhahn
DPDuhm-Harbeck Petra
Duhm-Harbeck Petra
IJIngenerf Josef
Ingenerf Josef
With the proliferation of digital communication in healthcare, the reuse of laboratory test data entails valuable insights into clinical and scientific issues, basically enabled by semantic standardization using the LOINC coding system. In order to extend the currently limited potential for analysis, which is mainly caused by structural peculiarities of LOINC, an algorithmic transformation of relevant content into an OWL ontology was performed, which includes LOINC Terms, Parts and Hierarchies. For extending analysis capabilities, the comprehensive SNOMED CT ontology is added by transferring its contents and the recently published LOINC-related mapping data into OWL ontologies. These formalizations offer rich, computer-processable content and allow to infer additional structures and relationships, especially when used together. Consequently, various reutilizations are facilitated; an application demonstrating the dynamic visualization of fractional hierarchy structures for user-supplied laboratory data was already implemented. By providing element-wise aggregation via superclasses, an adaptable, graph representation is obtained for studying categorizations.

18 May 2023
Verified
Book Chapter
Open access
PDF file
JWJoshua Philip Wiedekopf
Joshua Philip Wiedekopf
CDCora Drenkhahn
Cora Drenkhahn
JIJosef Ingenerf
Josef Ingenerf
Interoperability in healthcare cannot be achieved without mapping local data to standardized terminology. In this paper, we investigate the performance of different approaches for implementing HL7 FHIR Terminology Module operations using a benchmarking methodology, to gather evidence on the benefits and pitfalls of these methods in terms of performance from the point-of-view of a terminology client. The approaches perform very differently, while having a local client-side cache for all operations is of supreme importance. The results of our investigation show that careful consideration of the integration environment, potential bottlenecks, and implementation strategies is required.