To achieve the best explosion suppression effect of an active powder spraying system, the KHCO3 powder suppression test for a 9.5% methane-air premixed methane explosion was studied based on an independent test platform consisting of a pipe network. The suppression effect of KHCO3 powder particle size and powder spraying pressure on the methane explosion shock wave pressure, flame wave velocity, and flame wave temperature were studied, and the explosion suppression mechanism was analyzed. The results indicated that both the particle size of the KHCO3 powder and powder spraying pressure had a significant effect on the explosion inhibition. When the spraying pressure was in the range of 0.1-0.2 MPa, the increase in KHCO3 powder spraying pressure on the effect of explosion suppression was significantly enhanced, and when the powder spraying pressure exceeded 0.2 MPa, the explosion suppression effect did not obviously increase. With a reduction in the KHCO3 powder particle size, the effect of explosion suppression significantly improved, and when the KHCO3 powder particle size was reduced to 50-75 μm, we observed the best shock wave pressure, flame wave velocity, and flame wave temperature suppression effect.
To explore an effective approach for suppressing methane explosions in actual pipe networks, we used a custom-made diagonal pipe network experimental system to assess the suppression of methane explosions using a fine water mist containing KCl and an inert gas. The shock wave pressure, flame wave velocity, and flame wave temperature under different suppression conditions were compared to characterize the effects of explosion suppression under different working conditions, and the mechanism of explosion suppression was analyzed. The results showed that under single-factor explosion suppression conditions the optimal explosion suppression results were achieved when the volume fraction of N2 was 25%, the volume fraction of CO2 was 20%, and the concentration of KCl was 7%. The suppression effect of CO2 on the flame wave temperature was better than fine water mist containing KCl and N2, and the suppression effect of fine water mist containing KCl on the shock wave overpressure and flame wave velocity was more significant. Under the working conditions of fine water mist containing KCl, which was coupled with an inert gas to suppress the explosion, the suppression effect of the fine water mist containing KCl coupled with 20% CO2 on the shock wave overpressure, flame wave velocity, and flame wave temperature was considerably better than fine water mist containing KCl coupled with 25% N2.
This study examines smoke spread in an underground mall fire under the composite smoke control mode of a smoke barrier and a mechanical smoke exhaust system. The objective is to optimize the selection of smoke containment and exhaust methods in an underground mall in Fuxin City, China. A Fire Dynamics Simulator was used for numerical simulation to investigate the effects of the sagging height and spacing of smoke barriers on smoke containment, as well as the effects of size, number, and arrangement of smoke vents in the mechanical smoke exhaust system on the effectiveness of smoke exhaust. The results indicated that a smoke barrier with a sagging height of 1 m and a spacing of 5 m was effective in preventing the spread of high-temperature smoke. When the sagging height of the smoke barrier increased to 1.2 m, the smoke barrier effect was comparable to that of a 1 m height barrier. Regarding the mechanical smoke exhaust system, the size of the opening area of the smoke vent had no significant effect on the smoke exhaust effect. The best smoke exhaust effect was achieved when the number of smoke vents was 12. Additionally, the double-row setting of smoke vents was more efficient than the single-row setting. Combining a smoke barrier and a mechanical smoke exhaust system can provide a more effective smoke control compared to either system alone. Comprehensively, considering the effectiveness and economy of smoke containment and exhaust, the optimal combination of smoke containment and exhaust was determined to be a smoke barrier with a sagging height of 1 m and spacing of 5 m, and a mechanical smoke exhaust system with 12 smoke vents in a double-row arrangement.
In order to obtain the propagation and attenuation characteristics of a shock wave gas–coal dust explosion, a diagonal pipeline network was built to carry out a gas–coal dust explosion experiment. Methane with a volume fraction of 9.5% was mixed with 20 g of coal dust with a particle size of 50 μm. The shock wave attenuation characteristics in the diagonal pipeline network were characterized by the overpressure attenuation coefficient. The results showed that when the shock wave propagated in the diagonal pipeline network, it was offset and superposed multiple times. The overpressure attenuation in diagonal pipes was greater than that in the other pipeline branches. Secondary explosions occurred at all monitoring points. The propagation characteristics of shock waves is less affected by the pipeline network structure when it is close to the outlet of pipeline network. Nonlinear multivariate regression analysis was carried out to analyze the relationship between the overpressure attenuation coefficient and two adjacent monitoring points, the pressure before and after attenuation, and the pipeline angle. The functional relationship was in good agreement with the experiment data.