Anthony J Lamanna

Prof. Anthony J Lamanna

Del E. Webb School of Construction, Arizona State University, Tempe, Arizona, USA
orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2004 in Journal of Composites for Construction
Verified
Journal Article
Closed access
Anthony J LamannaAnthony J Lamanna
Anthony J Lamanna
Lawrence C. BankLawrence C. Bank
Lawrence C. Bank
DSDavid W. Scott
David W. Scott
The current method of bonding fiber-reinforced polymer (FRP) strengthening strips to concrete structures requires extensive time and semiskilled labor. An alternative method is to use a commercial off-the-shelf powder-actuated fastening system to attach FRP strips to concrete. A series of flexural tests were conducted on 15 304.8×304.8×3,657.6mm (12×12×144in.) reinforced concrete beams. Two beams were tested unstrengthened, 12 were strengthened with mechanically fastened FRP strips, and one was strengthened with a bonded FRP strip. The effects of three different strip moduli, different fastener lengths and layouts, and predrilling were examined. Three of the beams strengthened with mechanically attached FRP strips showed strengthening comparable to the beam strengthened with a bonded FRP strip. The same three beams strengthened with mechanically attached FRP strips also showed a greater ductility than the beam strengthened with a bonded FRP strip.

26 August 2022 in Resources, Conservation and Recycling
Verified
Journal Article
Closed access
FPFarideh Pahlavan
Farideh Pahlavan
Anthony J LamannaAnthony J Lamanna
Anthony J Lamanna
KPKi-Bum Park
Ki-Bum Park
SKSk Faisal Kabir
Sk Faisal Kabir
JKJoo-Sik Kim
Joo-Sik Kim
EFElham H. Fini
Elham H. Fini

1 June 2008 in Journal of Composites for Construction
Verified
Journal Article
Closed access
JMJeremy A. Martin
Jeremy A. Martin
Anthony J LamannaAnthony J Lamanna
Anthony J Lamanna
The use of adhesively bonded fiber-reinforced polymer (FRP) materials has become widely accepted for use in flexural strengthening applications; however, the method of attachment presents drawbacks in application. These include extensive time and labor investments, as well as a tendency of the system to fail in a brittle manner. This paper presents a study of a series of reinforced concrete beams each strengthened in flexure with an FRP strip attached with large diameter concrete screws. The concrete screws were arranged in a variety of patterns. The effect of fastener number and spacing, as well as the effect of fastener pattern on the behavior of the beam, was investigated through the use of two groups of specimens. The beams in each group were tested to failure to verify the behavior of the strengthening system. Measured behavior was then used to determine an analytical approach for prediction of load response behavior of mechanically fastened systems. It was found that the strengthening method investi...

1 May 2007 in Construction and Building Materials
Verified
Journal Article
Closed access
AAArda Akbiyik
Arda Akbiyik
Anthony J LamannaAnthony J Lamanna
Anthony J Lamanna
WHWilliam Micah Hale
William Micah Hale

1 December 2004 in Advances in Structural Engineering
Verified
Journal Article
Closed access
Anthony J LamannaAnthony J Lamanna
Anthony J Lamanna
Lawrence C. BankLawrence C. Bank
Lawrence C. Bank
DBDavid T. Borowicz
David T. Borowicz
A new method has been developed for strengthening reinforced concrete beams for flexure which uses multiple mechanical fasteners to attach a fiber reinforced polymer (FRP) strip to the member. This study investigates the behavior of the method on full scale concrete T beams of three different steel reinforcement levels. The beams were strengthened without surface preparation, and the strips were attached with only four man-hours of labor per beam. The strengthened beams resulted in increases of up to 11.7 % in the yield moment and up to 27.2 % in the moment capacity at a deflection of L/135. The beams exhibited large amounts of ductility, before failure.

27 July 2024 in Resources, Conservation and Recycling
Verified
Journal Article
Closed access
FPFarideh Pahlavan
Farideh Pahlavan
HKHarpreet Kaur
Harpreet Kaur
LALaura K.G. Ackerman-Biegasiewicz
Laura K.G. Ackerman-Biegasiewicz
Anthony J LamannaAnthony J Lamanna
Anthony J Lamanna
EFElham H. Fini
Elham H. Fini