Ernst Michael JUNG

Prof. Ernst Michael JUNG

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 June 2020 in Clinical Hemorheology and Microcirculation
Verified
Journal Article
Open access
PDF file
EJErnst Michael JUNG
Ernst Michael JUNG
CSC. Stroszczynski
C. Stroszczynski
FJF. Jung
F. Jung
In the hands of experienced examiners, the contrast enhanced sonography (CEUS) offers the possibility to analyze dynamic microcirculatory disturbances in real time dynamically without any risk for kidneys and thyroid gland even in severe progressing

17 December 2021 in Clinical Hemorheology and Microcirculation
Verified
Journal Article
Open access
PDF file
EJErnst Michael JUNG
Ernst Michael JUNG
JDJ. Dinkel
J. Dinkel
NVN. Verloh
N. Verloh
MBM. Brandenstein
M. Brandenstein
CSC. Stroszczynski
C. Stroszczynski
JRJ. Rennert
J. Rennert
AIM: To evaluate the diagnostic reliability of a new generation wireless point-of care ultrasound device for abdominal and thoracic findings. MATERIAL AND METHODS: 40 patients (16 females, 24 males 19 –80 years, on average 56.1 years) were scanned by an experienced examiner using the new wireless Vscan Air device for abdominal and thoracic findings. The probe frequencies were 2–5 MHz (convex probe) and 3–12 MHz for the linear probe. As a reference standard, all patients were also examined using high-end ultrasound (LOGIQ E9/LOGIQ E10). Results were interpreted independently by two examiners in consensus, also with regard to the image quality (0–4, from not assessable = 0, to excellent 4). RESULTS: In all 40 patients (100%) examination with conventional high-end ultrasound and the Vscan Air ultrasound device was feasible. Sensitivity, specificity, positive and negative predictive value for the diagnosis of abdominal and thoracic findings were 63.3%, 100%, 100%, and 40%, respectively. Most main diagnostic findings were detected using the mobile device compared to the high-end ultrasound. Limitations were found regarding characterization and classification of hepatic and renal tumorous lesions. Image quality revealed mostly minor diagnostic limitations for the mobile device, mean 2.9 (SD ± 0.300) and was excellent or with only minor diagnostic limitations for conventional high-end ultrasound, mean 3.25 (SD ± 0.438). CONCLUSION: Due to its easy application and its high diagnostic reliability, point-of-care ultrasound systems of the latest generation represent a valuable imaging method for the primary assessment of abdominal and thoracic findings, especially in patients on intensive care units or in emergency situations.

22 July 2020 in Clinical Hemorheology and Microcirculation
Verified
Journal Article
Open access
PDF file
EJErnst Michael JUNG
Ernst Michael JUNG
CSC. Stroszczynski
C. Stroszczynski
FJF. Jung
F. Jung
AIM: Use of contrast enhanced ultrasound (CEUS) in severe cases of Covid-19 infection to assess pulmonary changes near the pleura. MATERIAL AND METHODS: Bedside examinations by an experienced intensive care unit examiner using a multi-frequency probe

21 April 2023 in Clinical Hemorheology and Microcirculation
Verified
Journal Article
Open access
PDF file
EJErnst Michael JUNG
Ernst Michael JUNG
CSC. Stroszczynski
C. Stroszczynski
FJF. Jung
F. Jung
Goal of the study was the assessment of AI-assisted diagnosis of solid thyroid foci with multimodal modern ultrasound imaging. 50 patients (26–81 years, 54.7±13.1 years) were included in the study. Multimodal ultrasound imaging by means of B-mode wi

29 September 2022 in Cancers
Verified
Journal Article
Open access
PDF file
MBMoritz Brandenstein
Moritz Brandenstein
IWIsabel Wiesinger
Isabel Wiesinger
JKJulian Künzel
Julian Künzel
MHMatthias Hornung
Matthias Hornung
CSChristian Stroszczynski
Christian Stroszczynski
EJErnst Michael JUNG
Ernst Michael JUNG
Background: The aim was to improve preoperative diagnostics of solid non-cystic thyroid lesions by using new high-performance multiparametric ultrasound examination techniques. Methods: Multiparametric ultrasound consists of B-mode, shear-wave elastography and contrast enhanced ultrasound (CEUS) including Time-Intensity-Curve (TIC) analysis. A bolus of 1–2.4 mL Sulfur Hexafluorid microbubbles was injected for CEUS. Postoperative histopathology was the diagnostic gold standard. Results: 116 patients were included in this study. 102 benign thyroid nodules were diagnosed as well as 20 carcinomas. Suspicious B-mode findings like microcalcifications, a blurry edge and no homogeneous sonomorphological structure were detected in 60, 75 and 80% of all carcinomas but only in 13.7, 36.3 and 46.1% of all benign lesions. The average shear-wave elastography measurements of malignant lesions (4.6 m/s or 69.8 kPa centrally and 4.2 m/s or 60.1 kPa marginally) exceed the values of benign nodules. Suspicious CEUS findings like a not-homogeneous wash-in and a wash-out were detected almost twice as often in carcinomas. Conclusion: Multiparametric ultrasound offers new possibilities for the preoperative distinction between benign and malignant thyroid nodules. A score based system of B-mode, shear-wave and CEUS malignancy criteria shows promising results in the detection of thyroid carcinomas. It reaches a sensitivity of 95% and specificity of 75.49%.

27 April 2017 in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
Verified
Journal Article
Closed access
PDF file
SHSeverin Huf
Severin Huf
NSNatascha Platz Batista da Silva
Natascha Platz Batista da Silva
IWIsabel Wiesinger
Isabel Wiesinger
MHMatthias Hornung
Matthias Hornung
MSMarcus N. Scherer
Marcus N. Scherer
EJErnst Michael JUNG
Ernst Michael JUNG
Purpose To evaluate the diagnostic significance of preoperatively and intraoperatively performed contrast-enhanced ultrasound (CEUS/IOCEUS) in the diagnosis of liver tumors in comparison to magnetic resonance imaging (MRI) and histopathology. Materials and Methods Retrospective analysis of 70/317 patients who underwent surgery for liver tumors between January 2012 and October 2015. Findings of CEUS and IOCEUS were compared to MRI. CEUS and IOCEUS were performed using multifrequency linear probes (1 – 5, 6 – 15 MHz) after bolus injection of 1 – 5 ml sulfur hexafluoride microbubbles. The histopathology after surgical resection, MRI morphology (T1, T2, VIBE, diffusion sequences) and wash-in/wash-out kinetics of CEUS were evaluated. Results In 70 analyzed patient cases, 64 malignant liver lesions could be detected. 6 patients had benign liver lesions. Among the 64 malignant lesions, there were 28 metastases, 24 hepatocellular carcinomas (HCC), 9 cholangiocellular carcinomas (CCC) and 3 gallbladder carcinomas. 2 of the 6 benign liver lesions were hemangiomas, 2 were adenomas, 1 was an FNH and 1 was a complicated cyst. There was no significant difference when determining the lesion’s malignancy/ benignity (p = 1.000). Furthermore, there was no statistical significance between preoperative CEUS and MRI regarding the general differential diagnosis of a tumor (p = 0.210) and the differential diagnosis classification between HCCs (p = 0.453) and metastases (p = 0.250). There was no statistical significance in tumor size (10 mm – 151 mm; mean 49 mm SD +/– 31 mm) and location (tumor size p = 0.579; allocation to liver lobes p = 0.132; segment diagnosis p = 0.121) between preoperatively performed CEUS and MRI. The combination of preoperative MRI and CEUS for lesion detection showed significant differences compared to CEUS or MRI only (p < 0.001 for CEUS; p = 0.004 for MRI). IOCEUS offered the substantial advantage of locating additional liver lesions (p = 0.004 compared to preoperative MRI, p = 0.002 compared to preoperative CEUS). In 10/37 cases (27 %) IOCEUS could locate further liver lesions which had not been identified during CEUS and/or MRI preoperatively, so that operative therapy was adapted accordingly and resection was extended if necessary. Conclusion CEUS proves to be a dynamic imaging method for preoperative diagnosis of liver tumors showing high diagnostic significance in the characterization of a tumor’s microvascularization, its entity and its size. During liver operations CEUS plays an important role in surgical therapy decisions. Citation Format