Lin Xie

Lin Xie


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 May 2022 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
CLCan Li
Can Li
WHWei He
Wei He
NWNan Wang
Nan Wang
ZXZhipeng Xi
Zhipeng Xi
RDRongrong Deng
Rongrong Deng
Xin LiuXin Liu
Xin Liu
Tumor metastasis is one of the main causes of cancer incidence and death worldwide. In the process of tumor metastasis, the isolation and analysis of circulating tumor cells (CTCs) plays a crucial role in the early diagnosis and prognosis of cancer patients. Due to the rarity and inherent heterogeneity of CTCs, there is an urgent need for reliable CTCs separation and detection methods in order to obtain valuable information on tumor metastasis and progression from CTCs. Microfluidic technology is increasingly used in various studies of CTCs separation, identification and characterization because of its unique advantages, such as low cost, simple operation, less reagent consumption, miniaturization of the system, rapid detection and accurate control. This paper reviews the research progress of microfluidic technology in CTCs separation and detection in recent years, as well as the potential clinical application of CTCs, looks forward to the application prospect of microfluidic technology in the treatment of tumor metastasis, and briefly discusses the development prospect of microfluidic biosensor.

13 August 2021 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
JLJingchi Li
Jingchi Li
CXChen Xu
Chen Xu
XZXiaoyu Zhang
Xiaoyu Zhang
ZXZhipeng Xi
Zhipeng Xi
SSShenglu Sun
Shenglu Sun
YSYueming Song
Yueming Song
Backgrounds: Finite element analysis (FEA) is an important tool during the spinal biomechanical study. Irregular surfaces in FEA models directly reconstructed based on imaging data may increase the computational burden and decrease the computational credibility. Definitions of the relative nucleus position and its cross-sectional area ratio do not conform to a uniform standard in FEA. Methods: To increase the accuracy and efficiency of FEA, nucleus position and cross-sectional area ratio were measured from imaging data. A FEA model with smoothened surfaces was constructed using measured values. Nucleus position was calibrated by estimating the differences in the range of motion (RoM) between the FEA model and that of an in-vitro study. Then, the differences were re-estimated by comparing the RoM, the intradiscal pressure, the facet contact force, and the disc compression to validate the measured and calibrated indicators. The computational time in different models was also recorded to evaluate the efficiency. Results: Computational results indicated that 99% of accuracy was attained when measured and calibrated indicators were set in the FEA model, with a model validation of greater than 90% attained under almost all of the loading conditions. Computational time decreased by around 70% in the fitted model with smoothened surfaces compared with that of the reconstructed model. Conclusions: The computational accuracy and efficiency of in-silico study can be improved in the lumbar FEA model constructed using smoothened surfaces with measured and calibrated relative nucleus position and its cross-sectional area ratio.

14 May 2019 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
JLJINGCHI LI
JINGCHI LI
WXWenqiang Xu
Wenqiang Xu
XZXiaoyu Zhang
Xiaoyu Zhang
ZXZhipeng Xi
Zhipeng Xi
LXLin Xie
Lin Xie
Variation in the biomechanical characteristics of intervertebral discs adjacent to the segment disc after undergoing percutaneous transforaminal endoscopic discectomy (PTED) in models with normal and abnormal bone mineral density (BMD) was estimated using the finite element method. The study investigated the change in the incidence of adjacent segment disease (ASD) after PTED in patients without and with osteoporosis. PTED has been widely used for treating lumbar disc herniation (LDH); changes in BMD will affect biomechanical characteristics, possibly leading to changes in the incidence of ASD after PTED. However, this issue remains largely unclear. A non-linear, lumbosacral finite element model was reconstructed based on imaging data and validated using compared values computed by the current model from published and well-validated, in vitro biomechanical experiment studies. Corresponding PTED models with normal and abnormal BMDs were also reconstructed. Shear and von Mises stresses on the annulus fibrosis, the von Mises stress on the endplates in L5–S1 segment discs, and the total deformation of current lumbosacral models were computed in different body positions by changing loading conditions, including flexion, extension, left and right lateral bending, and axial rotation. In most loading conditions, biomechanical characteristics of the lumbosacral segment discs with normal BMDs after PTED slightly increased. However, in the PTED model with osteoporosis, most of the biomechanical characteristics dramatically increased. Osteoporosis leads to the deterioration of biomechanical characteristics in the adjacent segment disc after PTED; this variation may also result in an increase in the incidence of ASD. However, further studies on the interactions between pathological changes are warranted.

10 July 2021 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
JLJingchi Li
Jingchi Li
CXChen Xu
Chen Xu
XZXiaoyu Zhang
Xiaoyu Zhang
ZXZhipeng Xi
Zhipeng Xi
MLMengnan Liu
Mengnan Liu
YSYueming Song
Yueming Song
Background: Facetectomy, an important procedure in the in–out and out–in techniques of transforaminal endoscopic lumbar discectomy (TELD), is related to the deterioration of the postoperative biomechanical environment and poor prognosis. Facetectomy may be avoided in TELD with large annuloplasty, but iatrogenic injury of the annulus and a high grade of nucleotomy have been reported as risk factors influencing poor prognosis. These risk factors may be alleviated in TELD with limited foraminoplasty, and the grade of facetectomy in this surgery can be reduced by using an endoscopic dynamic drill. Methods: An intact lumbo-sacral finite element (FE) model and the corresponding model with adjacent segment degeneration were constructed and validated to evaluate the risk of biomechanical deterioration and related postoperative complications of TELD with large annuloplasty and TELD with limited foraminoplasty. Changes in various biomechanical indicators were then computed to evaluate the risk of postoperative complications in the surgical segment. Results: Compared with the intact FE models, the model of TELD with limited foraminoplasty demonstrated slight biomechanical deterioration, whereas the model of TELD with large annuloplasty revealed obvious biomechanical deterioration. Degenerative changes in adjacent segments magnified, rather than altered, the overall trends of biomechanical change. Conclusions: TELD with limited foraminoplasty presents potential biomechanical advantages over TELD with large annuloplasty. Iatrogenic injury of the annulus and a high grade of nucleotomy are risk factors for postoperative biomechanical deterioration and complications of the surgical segment.

17 December 2013 in RSC Advances
Verified
Journal Article
Closed access
PDF file
RKRan Kang
Ran Kang
Yonglun LuoYonglun Luo
Yonglun Luo
LZLijin Zou
Lijin Zou
LXLin Xie
Lin Xie
HLHelle Lysdahl
Helle Lysdahl
CBCody Bünger
Cody Bünger
Biomimetic nanofibrous scaffolds combined with stem cells are promising for bone tissue engineering. In the present study, we have employed nano-hydroxyapatite (nHAp) contained polycaprolactone (PCL) nanofibers as a biomimetic nanofibrous scaffold, and mesenchymal stem cells derived from human induced pluripotent stem cells (hiPS-MSCs) as the novel stem cells sources. The response of hiPS-MSCs on the nanofibrous scaffolds in terms of cell proliferation and differentiation into the osteoblastic phenotype was investigated by XTT assay, scanning electron microscopy (SEM), osteogenic genes expression (runt-related transcription factor 2 (RUNX2), alkaline phosphatase (ALP), collagen I (COL1A1), and osteocalcin (OC)), ALP activity, and calcium deposition. It is clearly shown that the hiPS-MSCs attached, and proliferated on the nanofibrous scaffolds. Compared with PCL nanofibers without nHAp, the cells on the nHAp contained nanofibers demonstrated superior capabilites to differentiate to form calcified extracellular matrix. Together with gene expression, all of the results indicate the great potential of the hiPS-MSCs seeded biomimetic nanofibrous scaffolds for bone regeneration in the future.

9 August 2019 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
JLJINGCHI LI
JINGCHI LI
XZXiaoyu Zhang
Xiaoyu Zhang
WXWenqiang Xu
Wenqiang Xu
ZXZhipeng Xi
Zhipeng Xi
LXLin Xie
Lin Xie
Percutaneous transforaminal endoscopic discectomy (PTED) is widely used for the treatment of lumbar disc herniation. Facetectomy in PTED is necessary for accessing the intraspinal region and for decompressing the exiting nerve roots in patients who suffer from hypertrophy of the facet joints. However, this may increase morbidity in failed back surgery syndrome (FBSS) and has not been clearly elucidated. A three-dimensional lumbosacral model was reconstructed and validated. And corresponding models after PTED with one-quarter and one-half excisions of the superior articular process were reconstructed. The maximum shear stress on the annulus in L5, von Mises stress of the facet cartilage, maximum principle capsular strain and deformation of the lumbosacral model were calculated using finite element methods. Calculated results show no significant differences in the complete model and the model with one-quarter excision of the superior articular process, but all biomechanical indexes have been deteriorated under most of the loading conditions tested in the model with one-half excision of the superior articular process. Less facetectomy is better because it may reduce the risk of biomechanical deterioration and consequently, that of FBSS.