Yuting Chen

Ms. Yuting Chen

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 December 2022 in Advanced Engineering Materials
Verified
Journal Article
Closed access
QXQingchao Xia
Qingchao Xia
LXLinghui Xu
Linghui Xu
CLChen Liu
Chen Liu
YYYue Yang
Yue Yang
YCYuting Chen
Yuting Chen
CYCanjun Yang
Canjun Yang

25 April 2025
Verified
Conference Paper
Open access
CZCaroline Yan Zheng
Caroline Yan Zheng
YCYuting Chen
Yuting Chen
ALAdrian Latupeirissa
Adrian Latupeirissa
Georgios AndrikopoulosGeorgios Andrikopoulos
Georgios Andrikopoulos
ASAnna Ståhl
Anna Ståhl
MBMadeline Balaam
Madeline Balaam

30 May 2024 in IEEE Transactions on Medical Robotics and Bionics
Verified
Journal Article
Closed access
LXLinghui Xu
Linghui Xu
YCYuting Chen
Yuting Chen
BFBingfei Fan
Bingfei Fan
Canjun YangCanjun Yang
Canjun Yang
WYWei Yang
Wei Yang
Wearable continuous gait phase estimation is essential for walking assistance, clinical rehabilitation, and clinical assessment; however, most algorithms have only been validated for straight-line and constant-speed walking, and it is unclear how performance will change in real-life locomotion scenarios. A generalized paradigm is needed to comprehensively assess and recommend wearable continuous gait phase estimation strategies for the diverse array of walking situations. We thus propose a comprehensive evaluation indicator system for eight typical gait activities in daily life including slow walking, standard walking, running, walking with turns, stair descent, stair ascent, stop-and-go, and uneven terrain walking. The indicator system was used to evaluate four commonly used continuous gait phase estimation strategies: adaptive oscillators, phase oscillator, neural network, and time-based estimation. Eleven healthy participants were enrolled in the evaluation. All estimation strategies performed well for constant-speed walking but performance varied for other activities. Time-based estimation was most accurate for slow walking (0.094±0.011 rad root mean square error, 1.50±0.18% of one gait cycle), running (0.167±0.028 rad, 2.66±0.44%) and walking with turns (0.124±0.047 rad, 2.00±0.75%). Adaptive oscillators were most accurate for standard walking (0.115±0.037 rad, 1.83±0.59%). Phase oscillator was most accurate for stair climbing (0.280±0.063 rad, 4.46±1.00%) and uneven terrain (0.204±0.069 rad, 4.30±1.10%). Neural network was most accurate for stop-and-go (0.27±0.114 rad, 4.30±1.81%). These results can potentially provide guidance for determining suitable gait phase estimation strategies in realistic locomotion scenarios, and in comparing and optimizing the current proposed strategies.

30 July 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YLYi Liu
Yi Liu
YCYuting Chen
Yuting Chen
XJXiaowu Jiang
Xiaowu Jiang
QNQianying Ni
Qianying Ni
CLChen Liu
Chen Liu
SZSheng Zhang
Sheng Zhang
Intuitive self-assembly devices are of great significance to the emerging applications of self-assembly theory. In this paper, a novel intuitive device with an aerodynamic system is fabricated for the self-assembly experiment. Table tennis balls were used as the objects to be assembled during the self-assembly process. To understand more about the system, two experiments were designed—the directed assembly experiment was conducted to organize a specific structure and to explore the influences of environmental variables, and the indirect assembly experiment repeated with the “bottom-up” self-organization process and expressed the characteristics of “the optimization” and “the emergence” in the self-organization process. This article expressed a novel self-assembly approach at a macroscale and created a new choice or idea for the structural design and the optimization method.

24 September 2025 in IEEE Sensors Journal
Verified
Journal Article
Open access
YCYuting Chen
Yuting Chen
LXLinghui Xu
Linghui Xu
MBMadeline Balaam
Madeline Balaam
Georgios AndrikopoulosGeorgios Andrikopoulos
Georgios Andrikopoulos
Tactile sensors play a key role in human-machine interaction (HMI), providing essential tactile measurement capabilities for this field, where their performance directly determines the operational safety and haptic quality of HMI machines. When tactile sensors are applied to human or machine surfaces, their ability to fit comfortably and conform to the curves of the body is a significant challenge to address. Existing stretchable and flexible sensors show excellent adaptive conformability and accuracy. Yet, their fabrication methods usually rely on expensive and specialised equipment and are not accessible to many researchers from the interdisciplinary field of human-computer interaction to implement, customize and deploy. To address this problem, this paper proposes a stretchable pressure sensor of low-cost and fabrication complexity, drawing inspiration from the ancient paper-cutting art of Kirigami. The developed prototype is experimentally tested for its ability to conform to the human body, while being characterized by a high force-detection accuracy, with an average error of 4% in the range of 0 – 1000 g per cell), and the sampling electronics of it has demonstrated effective crosstalk elimination function. The proposed approach also serves as a methodology for rapid fabrication of flexible electronic devices, enabling high-precision continuous force monitoring across both preloaded (e.g., sitting/lying postures) and non-preloaded scenarios (e.g. contact detection).

17 December 2025 in IEEE Sensors Journal
Verified
Journal Article
Closed access
CZCaroline Yan Zheng
Caroline Yan Zheng
ALAdrian Latupeirissa
Adrian Latupeirissa
YCYuting Chen
Yuting Chen
KWKieran Woodward
Kieran Woodward
MBMadeline Balaam
Madeline Balaam
Georgios AndrikopoulosGeorgios Andrikopoulos
Georgios Andrikopoulos
To enable better human-machine and human-robot interaction in healthcare applications, there is a need to improve haptic devices, assistive and companion robots to touch humans in a way that can be perceived as comfortable, safe and trusting. Towards this vision, we developed a flexible, wearable matrix force-sensing garment capable of recording dynamic force behaviour of caring touch from four healthcare experts in their natural therapy environment, and enable the touch recipient to provide feedback on the perceived quality of the same touches. Instead of assuming particular touch gestures are caring, we explored the application of the sensing and analysing system to characterise a caring quality of touch across different gestures. We were able to characterise distinctive features for touch aimed for sensory aspects and for moving the body. Our findings demonstrate that caring touch is not limited to specific gestures or a single parameter but is rather characterised by how the touch is performed across multiple features, with deliberateness - the careful and smoothness in the increasing and decreasing of force, emerging as a shared characteristic of caring touch regardless of the specific gesture employed. The study also demonstrates the feasibility of using raw tactile sensor data to assess subjective touch quality.