Oil-immersed paper is a weak link in internal insulation of oil immersed power transformer, whose aging state distributes inhomogeneously. However, most of the current assessment methods fail to consider the spatial distribution of aging areas inside transformer. Aiming at this problem, this paper proposes the inversion detection method to obtain the resistivity of oil-immersed paper in various regions nondestructively, and uses the resistivity of oil-immersed paper to assess directly the insulation state of oil immersed power transformers. Finite element method is applied to establish the mapping relationship between the resistivity of oil-immersed paper in different regions, and the dielectric loss factor obtained from the port of transformer. Back propagation neural network is used to learn inversely this mapping relationship so as to calculate the resistivity. Applying the proposed method on a 10-kV transformer, the calculated results are close to the measured values. The study shows that the inversion method can effectively calculate the oil-immersed resistivity in various regions, which represent the aging state in different regions of the transformer.
The resistivity of oil impregnated paper will decrease during its aging process. This paper takes paper resistivity as an assessment index to evaluate the insulation condition of oil impregnated paper in power transformer. The feasibility of this method are discussed in two aspects: reliability and sensitivity. Iterative inversion of paper resistivity was combined with finite element simulation. Both the bisection method and Newton’s method were used as iterative methods. After the analysis and comparison, Newton’s method was selected as the first option of paper resistivity iteration for its faster convergence. In order to consider the spatial distribution characteristic of paper aging and enhance the calculation accuracy, the resistivity calculation is expanded to a multivariate iteration based on Newton’s method, in order to consider the spatial distribution characteristic of paper aging and improve the calculation accuracy. This paper presents an exploratory research on condition assessment of oil impregnated paper insulation, and provides some reference to the security and economy operation of power transformers.
Inter-turn short circuit fault (ISCF) is the main fault type of dry-type air-core reactors (DARs), and the reactor burnout event caused by winding ISCF seriously threatens the safe and stable operation of the electric power system. In order to effectively curb the further worsening of ISCF in DARs, a fault detection method based on frequency response analysis was proposed. First, the effect of ISCF on the frequency response curve of the windings was investigated based on the distributed parameter model of DARs. Then, four sets of eigenvalues were proposed for ISCF diagnosis based on the influence law and curve data analysis theory. Finally, based on the eigenvalues, the support vector machine model optimized by the sparrow search algorithm was used to effectively classify the degree of ISCF of the reactor, and the accuracy reached 96%. Furthermore, a test platform was built based on the theoretical analysis for experimental verification, and the test results are consistent with the simulation results. Hence, the method proposed in this paper could effectively classify the ISCF and its severity in DARs. The research in this paper could provide effective guidance for the diagnosis of ISCF in DARs.
The regular operation of transformers is significantly impacted by the insulation effectiveness of the transformer insulation oil–paper. In order to explore the mechanism of the influence of an electric field on the thermal decomposition performance of insulating oil–paper, this paper simulated the process of electrothermal coupling decomposition of insulating oil–paper from the micro-level based on molecular dynamics. It was determined that the insulating oil is made up of three 16-carbon hydrocarbon molecules, while the insulating paper is made up of 30 fibrous disaccharide molecules. Using the molecular dynamics simulation approach, the pyrolysis of the insulating oil and insulating paper under various electric field strengths was simulated, and the lysis of reactants and the distribution of products were statistically examined. This paper also studied how the electric field affected the microscopic process of the insulating oil–paper pyrolysis. The findings demonstrate that under the influence of electrothermal coupling, the big molecules of the insulating oil and insulating paper are pyrolyzed to produce a variety of tiny molecules. For the insulating oil, it is easily subject to electron displacement polarization under the influence of an external electric field since it contains non-polar molecules, especially impacted by an electric field of 100 V/m. For the insulating paper, its polar nature, on the other hand, makes itself a good candidate for guiding polarization when exposed to an external electric field. So, the greater the electric field strength is, the greater the impact on the thermal decomposition of the insulating paper is.
Ensuring the structural reliability of power transmission networks is a fundamental prerequisite for the stable operation of modern energy systems. To address the challenges posed by complex weather interference and the small scale of insulator defects during power line inspections, this paper proposes LID-YOLO, a lightweight insulator defect detection network. First, to mitigate image feature degradation caused by weather interference, we design the C3k2-CDGC module. By leveraging the input-adaptive characteristics of dynamic convolution and the spatial preservation properties of coordinate attention, this module enhances feature extraction capabilities and robustness in complex weather scenarios. Second, to address the detection challenges arising from the significant scale disparity between insulators and defects, we propose Detect-LSEAM, a detection head featuring an asymmetric decoupled architecture. This design facilitates multi-scale feature fusion while minimizing computational redundancy. Subsequently, we develop the NWD-MPDIoU hybrid loss function to balance the weights between distribution metrics and geometric constraints dynamically. This effectively mitigates gradient instability arising from boundary ambiguity and the minute size of insulator defects. Finally, we construct a synthetic multi-weather condition insulator defect dataset for training and validation. Compared to the baseline, LID-YOLO improves precision, recall, and mAP@0.5 by 1.7%, 3.6%, and 4.2%, respectively. With only 2.76 M parameters and 6.2 G FLOPs, it effectively maintains the lightweight advantage of the baseline, achieving an optimal balance between detection accuracy and computational efficiency for insulator inspections under complex weather conditions. This lightweight and robust framework provides a reliable algorithmic foundation for automated grid monitoring, supporting the continuous and resilient operation of modern energy systems.