7 October 2009 in Journal of The Royal Society Interface
Verified
Journal Article
Closed access
CNCatherine Noakes
Catherine Noakes
PSP. Andrew Sleigh
P. Andrew Sleigh
Understanding the risk of airborne transmission can provide important information for designing safe healthcare environments with an appropriate level of environmental control for mitigating risks. The most common approach for assessing risk is to use the Wells–Riley equation to relate infectious cases to human and environmental parameters. While it is a simple model that can yield valuable information, the model used as in its original presentation has a number of limitations. This paper reviews recent developments addressing some of the limitations including coupling with epidemic models to evaluate the wider impact of control measures on disease progression, linking with zonal ventilation or computational fluid dynamics simulations to deal with imperfect mixing in real environments and recent work on dose–response modelling to simulate the interaction between pathogens and the host. A stochastic version of the Wells–Riley model is presented that allows consideration of the effects of small populations relevant in healthcare settings and it is demonstrated how this can be linked to a simple zonal ventilation model to simulate the influence of proximity to an infector. The results show how neglecting the stochastic effects present in a real situation could underestimate the risk by 15 per cent or more and that the number and rate of new infections between connected spaces is strongly dependent on the airflow. Results also indicate the potential danger of using fully mixed models for future risk assessments, with quanta values derived from such cases less than half the actual source value.

4 May 2021 in Indoor Air
Verified
Journal Article
Open access
PDF file
WHWaseem Hiwar
Waseem Hiwar
MKMarco-Felipe King
Marco-Felipe King
FSFARAG SHUWEIHDI
FARAG SHUWEIHDI
LFLouise A. Fletcher
Louise A. Fletcher
Professor StephanieProfessor Stephanie
Professor Stephanie
CNCatherine Noakes
Catherine Noakes
Airborne microorganisms in hospitals have been associated with several hospital‐acquired infections (HAIs), and various measures of indoor air quality (IAQ) parameters such as temperature, relative humidity, carbon dioxide (CO2), particle mass concentration, and particle size have been linked to pathogen survival or mitigation of pathogen spread. To investigate whether there are quantitative relationships between the concentration of airborne microorganisms and the IAQ in the hospital environment. Web of Science, Scopus and PubMed databases were searched for studies reporting airborne microbial levels and any IAQ parameter(s) in hospital environments, from database inception to October 2020. Pooled effect estimates were determined via random‐effects models. Seventeen of 654 studies were eligible for the meta‐analysis. The concentration of airborne microbial measured as aerobic colony count (ACC) was significantly correlated with temperature (r = 0.25 [95% CI = 0.06–0.42], p = 0.01), CO2 concentration (r = 0.53 [95% CI = 0.40–0.64], p ˂ 0.001), particle mass concentration (≤5 µg/m3; r = 0.40 [95% CI = 0.04–0.66], p = 0.03), and particle size (≤5 and ˃5 µm), (r = 0.51 [95% CI = 0.12–0.77], p = 0.01 and r = 0.55 [95% CI = 0.20–0.78], p = 0.003), respectively, while not being significantly correlated with relative humidity or particulate matter of size >5 µm. Conversely, airborne total fungi (TF) were not significantly correlated with temperature, relative humidity, or CO2 level. However, there was a significant weak correlation between ACC and TF (r = 0.31 [95% CI = 0.07–0.52], p = 0.013). Although significant correlations exist between ACC and IAQ parameters, the relationship is not definitive; the IAQ parameters may affect the microorganisms but are not responsible for the presence of airborne microorganisms. Environmental parameters could be related to the generating source, survival, dispersion, and deposition rate of microorganisms. Future studies should record IAQ parameters and factors such as healthcare worker presence and the activities carried out such as cleaning, sanitizing, and disinfection protocols. Foot traffic would influence both the generation of microorganisms and their deposition rate onto surfaces in the hospital environment. These data would inform models to improve the understanding of the likely concentration of airborne microorganisms and provide an alternative approach for real‐time monitoring of the healthcare environment.

1 December 2004 in Indoor and Built Environment
Verified
Journal Article
Closed access
CNCatherine Noakes
Catherine Noakes
CBC. B. Beggs
C. B. Beggs
PSP. A. Sleigh
P. A. Sleigh
Models to evaluate upper room ultraviolet germicidal irradiation (UVGI) devices can be used to improve the understanding of the behaviour of UV devices in ventilated rooms and so enable more confident predictions to be made of their performance. This paper presents two- and three-zone mixing models for investigating the effect of upper room UVGI devices in a typical ventilated room. The results from these analytical models are compared to a CFD simulation of the same room that incorporates the biological inactivation of micro-organisms in the presence of an ultraviolet field. The study demonstrates that analytical mixing models give reasonably good average zone concentrations and are therefore useful in estimating overall performance. However, the CFD simulations are necessary to fully examine the interaction of the room airflow with the inactivation of micro-organisms due to the UV field.

1 August 2006 in Indoor and Built Environment
Verified
Journal Article
Closed access
CNCatherine Noakes
Catherine Noakes
PSP. A. Sleigh
P. A. Sleigh
LFL. A. Fletcher
L. A. Fletcher
CBC. B. Beggs
C. B. Beggs
The installation of upper-room ultraviolet germicidal irradiation (UVGI) devices in ventilated rooms has the potential to reduce transmission of infections by an airborne route. However, the performance of such devices is dependant on several factors including the location of the lamp and the ventilation airflow in the room. This study uses a CFD model to evaluate the performance of UVGI devices by considering the cumulative UV-C dose received by the bulk room air in a ventilated room. By evaluating the UV dose rather than the resulting micro-organism inactivation the methodology can be used to optimise UVGI systems at the design stage, particularly when the source location of bioaerosol contaminants is not known. The study investigates the relationships between the lamp location, lamp power, ventilation system and room heating in a small, ventilated room. The results show that with ventilation air supplied at low level and extracted at high level the UVGI system performs better than with the air supplied at high level and extracted close to the floor. In addition the results show the presence of a heater in the room is unlikely to have a detrimental effect on performance and may promote mixing to increase the extent of disinfection.

13 July 2020 in PLOS Pathogens
Verified
Journal Article
Open access
PDF file
JNJonathan S. Nguyen-Van-Tam
Jonathan S. Nguyen-Van-Tam
BKBen Killingley
Ben Killingley
JEJoanne Enstone
Joanne Enstone
MHMichael Hewitt
Michael Hewitt
JPJovan Pantelic
Jovan Pantelic
FCfor the EMIT Consortium
for the EMIT Consortium
Uncertainty about the importance of influenza transmission by airborne droplet nuclei generates controversy for infection control. Human challenge-transmission studies have been supported as the most promising approach to fill this knowledge gap. Healthy, seronegative volunteer ‘Donors’ (n = 52) were randomly selected for intranasal challenge with influenza A/Wisconsin/67/2005 (H3N2). ‘Recipients’ randomized to Intervention (IR, n = 40) or Control (CR, n = 35) groups were exposed to Donors for four days. IRs wore face shields and hand sanitized frequently to limit large droplet and contact transmission. One transmitted infection was confirmed by serology in a CR, yielding a secondary attack rate of 2.9% among CR, 0% in IR (p = 0.47 for group difference), and 1.3% overall, significantly less than 16% (p<0.001) expected based on a proof-of-concept study secondary attack rate and considering that there were twice as many Donors and days of exposure. The main difference between these studies was mechanical building ventilation in the follow-on study, suggesting a possible role for aerosols. Understanding the relative importance of influenza modes of transmission informs strategic use of preventive measures to reduce influenza risk in high-risk settings such as hospitals and is important for pandemic preparedness. Given the increasing evidence from epidemiological modelling, exhaled viral aerosol, and aerobiological survival studies supporting a role for airborne transmission and the potential benefit of respirators (and other precautions designed to prevent inhalation of aerosols) versus surgical masks (mainly effective for reducing exposure to large droplets) to protect healthcare workers, more studies are needed to evaluate the extent of risk posed airborne versus contact and large droplet spray transmission modes. New human challenge-transmission studies should be carefully designed to overcome limitations encountered in the current study. The low secondary attack rate reported herein also suggests that the current challenge-transmission model may no longer be a more promising approach to resolving questions about transmission modes than community-based studies employing environmental monitoring and newer, state-of-the-art deep sequencing-based molecular epidemiological methods.

8 February 2022 in Indoor Air
Verified
Journal Article
Open access
PDF file
DMDaniel Miller
Daniel Miller
MKMarco-Felipe King
Marco-Felipe King
JNJames Nally
James Nally
JDJoseph R. Drodge
Joseph R. Drodge
GRGary I. Reeves
Gary I. Reeves
CNCatherine Noakes
Catherine Noakes
We propose the Transmission of Virus in Carriages (TVC) model, a computational model which simulates the potential exposure to SARS-CoV-2 for passengers traveling in a subway rail system train. This model considers exposure through three different routes: fomites via contact with contaminated surfaces; close-range exposure, which accounts for aerosol and droplet transmission within 2 m of the infectious source; and airborne exposure via small aerosols which does not rely on being within 2 m distance from the infectious source. Simulations are based on typical subway parameters and the aim of the study is to consider the relative effect of environmental and behavioral factors including prevalence of the virus in the population, number of people traveling, ventilation rate, and mask wearing as well as the effect of model assumptions such as emission rates. Results simulate generally low exposures in most of the scenarios considered, especially under low virus prevalence. Social distancing through reduced loading and high mask-wearing adherence is predicted to have a noticeable effect on reducing exposure through all routes. The highest predicted doses happen through close-range exposure, while the fomite route cannot be neglected; exposure through both routes relies on infrequent events involving relatively few individuals. Simulated exposure through the airborne route is more homogeneous across passengers, but is generally lower due to the typically short duration of the trips, mask wearing, and the high ventilation rate within the carriage. The infection risk resulting from exposure is challenging to estimate as it will be influenced by factors such as virus variant and vaccination rates.