Accurate and precise monitoring of kidney function is critical for a timely and reliable diagnosis of chronic kidney disease (CKD). The determination of kidney function usually involves the estimation of the glomerular filtration rate (eGFR). We recently reported the clinical performance of a new eGFR equation (GFRNMR) based on the nuclear magnetic resonance (NMR) measurement of serum myo-inositol, valine, and creatinine, in addition to the immunoturbidometric quantification of serum cystatin C, age and sex. We now describe the analytical performance evaluation of GFRNMR according to the Clinical and Laboratory Standards Institute guidelines. Within-laboratory coefficients of variation (CV%) of the GFRNMR equation did not exceed 4.3%, with a maximum CV% for repeatability of 3.7%. Between-site reproducibility (three sites) demonstrated a maximum CV% of 5.9%. GFRNMR stability was demonstrated for sera stored for up to 8 days at 2–10°C and for NMR samples stored for up to 10 days in the NMR device at 6 ± 2°C. Substance interference was limited to 4/40 (10.0%) of the investigated substances, resulting in an underestimated GFRNMR (for glucose and metformin) or a loss of results (for naproxen and ribavirin) for concentrations twice as high as usual clinical doses. The analytical performances of GFRNMR, combined with its previously reported clinical performance, support the potential integration of this NMR method into clinical practice.
An accurate estimate of glomerular filtration rate (eGFR) is essential for proper clinical management, especially in patients with kidney dysfunction. This prospective observational study evaluated the real-world performance of the nuclear magnetic resonance (NMR)-based GFRNMR equation, which combines creatinine, cystatin C, valine, and myo-inositol with age and sex. We compared GFRNMR performance to that of the 2021 CKD-EPI creatinine and creatinine-cystatin C equations (CKD-EPI2021Cr and CKD-EPI2021CrCys), using 115 fresh routine samples of patients scheduled for urinary iothalamate clearance measurement (mGFR). Median bias to mGFR of the three eGFR equations was comparably low, ranging from 0.4 to 2.0 mL/min/1.73 m2. GFRNMR outperformed the 2021 CKD-EPI equations in terms of precision (interquartile range to mGFR of 10.5 vs. 17.9 mL/min/1.73 m2 for GFRNMR vs. CKD-EPI2021CrCys; p = 0.01) and accuracy (P15, P20, and P30 of 66.1% vs. 48.7% [p = 0.007], 80.0% vs. 60.0% [p < 0.001] and 95.7% vs. 86.1% [p = 0.006], respectively, for GFRNMR vs. CKD-EPI2021CrCys). Clinical parameters such as etiology, comorbidities, or medications did not significantly alter the performance of the three eGFR equations. Altogether, this study confirmed the utility of GFRNMR for accurate GFR estimation, and its potential value in routine clinical practice for improved medical care.