Sarolta Borzsák

Dr. Sarolta Borzsák

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
MVMilán Vecsey-Nagy
Milán Vecsey-Nagy
ÁJÁdám Levente Jermendy
Ádám Levente Jermendy
MKMárton Kolossváry
Márton Kolossváry
BVBorbála Vattay
Borbála Vattay
MBMelinda Boussoussou
Melinda Boussoussou
BSBálint Szilveszter
Bálint Szilveszter
Although reaching target heart rate (HR) before coronary CT angiography (CCTA) is still of importance, adequate HR control remains a challenge for many patients. Purpose-built cardiac scanners may provide optimal image quality at higher HRs by further improving temporal resolution. We aimed to compare the amount of motion artifacts on CCTA acquired using a dedicated cardiac CT (DCCT) compared to a conventional multidetector CT (MDCT) scanner. We compared 80 DCCT images to 80 MDCT scans matched by sex, age, HR, and coronary dominance. Image quality was graded on a per-patient, per-vessel and per-segment basis. Motion artifacts were assessed using Likert scores (1: non-diagnostic, 2: severe artifacts, 3: mild artifacts, 4: no artifacts). Patients were stratified into four groups according to HR (70/min). Overall, 2328 coronary segments were evaluated. DCCT demonstrated superior overall image quality compared to MDCT (3.7 ± 0.4 vs. 3.3 ± 0.7, p < 0.001). DCCT images yielded higher Likert scores in all HR ranges, which was statistically significant in the 60–65/min, 66–70/min and >70/min ranges (3.9 ± 0.2 vs. 3.7 ± 0.2, p = 0.008; 3.5 ± 0.5 vs. 3.1 ± 0.6, p = 0.048 and 3.5 ± 0.4 vs. 2.7 ± 0.7, p < 0.001, respectively). Using a dedicated cardiac scanner results in fewer motion artifacts, which may allow optimal image quality even in cases of high HRs.

1 December 2021 in European Journal of Radiology
Verified
Journal Article
Open access
MVMilán Vecsey-Nagy
Milán Vecsey-Nagy
ÁJÁdám Levente Jermendy
Ádám Levente Jermendy
FSFerenc Imre Suhai
Ferenc Imre Suhai
APAlexisz Panajotu
Alexisz Panajotu
JCJudit Csőre
Judit Csőre
BSBalint Szilveszter
Balint Szilveszter
Filtered back projection (FBP) and adaptive statistical iterative reconstruction (ASIR) are ubiquitously applied in the reconstruction of coronary CT angiography (CCTA) datasets. However, currently no data is available on the impact of a model-based adaptive filter (MBAF2), recently developed for a dedicated cardiac scanner. Our aim was to determine the effect of MBAF2 on subjective and objective image quality parameters of coronary arteries on CCTA. Images of 102 consecutive patients referred for CCTA were evaluated. Four reconstructions of coronary images (FBP, ASIR, MBAF2, ASIR + MBAF2) were co-registered and cross-section were assessed for qualitative (graininess, sharpness, overall image quality) and quantitative [image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR)] image quality parameters. Image noise and signal were measured in the aortic root and the left main coronary artery, respectively. Graininess, sharpness, and overall image quality was assessed on a 4-point Likert scale. As compared to FBP, ASIR, and MBAF2, ASIR + MBAF2 resulted in reduced image noise [53.1 ± 12.3, 30.6 ± 8.5, 36.3 ± 4.2, 26.3 ± 4.0 Hounsfield units (HU), respectively; p < 0.001], improved SNR (8.4 ± 2.6, 14.1 ± 3.6, 11.8 ± 2.3, 16.3 ± 3.3 HU, respectively; p < 0.001) and CNR (9.4 ± 2.7, 15.9 ± 4.0, 13.3 ± 2.5, 18.3 ± 3.5 HU, respectively; p < 0.001). No difference in sharpness was observed amongst the reconstructions (p = 0.08). Although ASIR + MBAF2 was non-superior to ASIR regarding overall image quality (p = 0.99), it performed better than FBP (p < 0.001) and MBAF2 (p < 0.001) alone. The combination of ASIR and MBAF2 resulted in reduced image noise and improved SNR and CNR. The implementation of MBAF2 in clinical practice may result in improved noise reduction performance and could potentiate radiation dose reduction.

16 August 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
ZMZsuzsanna Mihály
Zsuzsanna Mihály
LILilla István
Lilla István
CCCecilia Czakó
Cecilia Czakó
FBFruzsina Benyó
Fruzsina Benyó
SBSarolta Borzsák
Sarolta Borzsák
PSPéter Sótonyi
Péter Sótonyi
The Circle of Willis (CoW) is the main collateral system, and its morphological variants are more common in patients who have severe carotid artery stenosis. Earlier data suggest that optical coherence tomography angiography (OCTA) may help to assess the changes in cerebral vascular perfusion by imaging the retinal blood flow. In this single-center prospective clinical study, patients scheduled for carotid endarterectomy (CEA) underwent preoperative computed tomography angiography (CTA) of the extra- and intracranial cerebral circulation. OCTA imaging was performed one week before surgery and postoperatively one month later. The patients were divided into two subgroups based on CTA evaluation of CoW: compromised CoW or non-compromised CoW (containing hypoplastic and normal segments). The effect of the patient’s age, OCTA scan quality (SQ), CoW morphology, laterality, and surgery on superficial capillary vessel density (VD) in the macula were assessed in multivariable regression models using linear mixed models. We found that VD significantly decreased with aging (−0.12%; 95%CI: −0.07–−0.15; p < 0.001) and was significantly higher in patients with non-compromised CoW morphology (by 0.87% 95%CI (0.26–1.50); p = 0.005). After CEA, retinal blood flow significantly improved by 0.71% (95%CI: 0.18–1.25; p = 0.01). These results suggest that in the case of carotid artery occlusion, patients with non-compromised CoW have more preserved ocular blood flow than subjects with compromised CoW due to remodeling of the intra-orbital blood flow. Measuring the retinal blood flow might be used as a relevant and sensitive indicator of collateral cerebrovascular circulation.

1 August 2022 in Neuroradiology
Verified
Journal Article
Open access
PDF file
AVAndrea Varga
Andrea Varga
GGGyula Gyebnár
Gyula Gyebnár
FSFerenc Imre Suhai
Ferenc Imre Suhai
ANAnikó Ilona Nagy
Anikó Ilona Nagy
LKLajos Rudolf Kozák
Lajos Rudolf Kozák
BMBéla Merkely
Béla Merkely
Purpose: We assessed diffusion tensor imaging (DTI) metric changes of the corpus callosum and cingulum correlated to postprocedural ischemic lesion load (ILL) and cognitive performance in transcatheter aortic valve replacement (TAVR). Methods: TAVR subjects had DTI post-TAVR (≤ 8 days) and at 6 months (78 participants, males 56%, age 78.8 years ± 6.3) and four neurocognitive tests (pre-TAVR, post-TAVR, 6 months, 1 year). DTI metrics (fractional anisotropy (FA), mean diffusivity (MD), axial diffusivity (AD), radial diffusivity (RD)) were calculated for 7 regions: corpus callosum (genu, body, splenium) and cingulum (cingulate gyrus, parahippocampal cingulum bilaterally). DTI metrics post-TAVR and at 6 months were compared with Student’s t-test (p < 0.0071) and ANOVA covarying for sex, ILL (p < 0.05) with post hoc analysis of ILL groups (p < 0.0167). Repeated-measures linear mixed-effect model (p < 0.05) was performed to investigate the effect of time and ILL on cognition. Results: At 6 months, significant decrease of the following DTI metrics was detected: AD (genu, body, splenium, right parahippocampal cingulum: p ≤ 0.0046); MD (body, both cingulate gyri: p ≤ 0.0050); RD (left cingulate gyrus: p = 0.0021); FA (splenium: p < 0.0001). ANOVA confirmed significant effect of female sex on AD + MD reduction (body, right cingulate gyrus) and AD reduction (left cingulate gyrus) (p ≤ 0.0254). Significant negative effect of ILL on some DTI metric changes was found (AD + MD-body: p ≤ 0.0050; MD-left cingulate gyrus: p = 0.0087). Cognitive performance remained stable with significant negative correlation of ILL and retrograde memory and visual scores (p ≤ 0.0483). Conclusion: Significant effect of TAVR on cerebral microstructural integrity was found with reduced diffusivities opposite to the trends reported in various neurodegenerative conditions/ageing, notably in women and lower ILL, and with preserved/improved cognition. Trial registration number. NCT02826200 at ClinicalTrials.gov; date of registration: 07. July 2016.

17 January 2025 in Neuroradiology
Verified
Journal Article
Open access
PDF file
AVAndrea Varga
Andrea Varga
CPCsongor Péter
Csongor Péter
MVMilán Vecsey-Nagy
Milán Vecsey-Nagy
GGGyula Gyebnár
Gyula Gyebnár
SBSarolta Borzsák
Sarolta Borzsák
PSPéter Sótonyi
Péter Sótonyi
Aims To test utility of diffusion MRI-derived indices in carotid endarterectomy (CEA), change of diffusion tensor imaging (DTI) metrics, cerebral white matter (WM) volumes were evaluated and predictors of overall mortality determined. Methods Prospectively enrolled participants had preoperative, immediate and late postoperative DTI after CEA. WM volumes, DTI metrics (fractional anisotropy, FA; axial, radial, mean diffusivities; AD, RD, MD, respectively) were calculated for the index/contralateral hemispheres at all time points. Temporal changes, predictors of log2-transformed WM volumes, DTI values were analyzed using linear mixed model. Uni- and multivariable Cox proportional hazards models were used to identify predictors of mortality. Results 60 subjects (57% male, 69.5 ± 7.2years) were included. Significantly increased AD and MD was observed in both hemispheres comparing the preoperative and immediate postoperative DTI metrics (index AD: β = 0.02 [95%CI:0.01,0.02], p < 0.001; index MD: β = 0.02 [95%CI:0.01,0.03], p < 0.001; contralateral AD: β = 0.01 [95%CI:0.01,0.02], p = 0.001; contralateral MD: β = 0.02 [95%CI:0.01,0.03], p = 0.003). The index MD decreased (β = 0.01 [95%CI:0.01,0.001], p = 0.04), bilateral WM volumes (index WM: β = 0.04 [95%CI:0.02,0.07], p < 0.001; contralateral WM: β = 0.05 [95%CI:0.03,0.07], p < 0.001) decreased significantly between the immediate and late postoperative scans. Postoperative contralateral FA correlated significantly with lower mortality (HR = 0.001 [95%CI:0.001,0.19], p = 0.02); postoperative contralateral RD (HR = 3.74 × 104 [95%CI:1.62,8.60 × 108], p = 0.04) and MD (HR = 1.19 × 105 [95%CI:1.03,1.37 × 1010], p = 0.049) were significant predictors of mortality. Conclusion The increase of various DTI metrics from pre-to-postoperative may be indicative of microstructural deterioration following CEA. Temporal changes between the immediate and late postoperative scans suggest, however, reversal of detrimental WM changes and clearance of presumed subclinical WM edema. Our results also imply, that preserved cerebral properties are protective after CEA.

29 June 2026 in Imaging
Verified
Journal Article
Open access
SBSarolta Borzsák
Sarolta Borzsák
BVBorbála Vattay
Borbála Vattay
MBMelinda Boussoussou
Melinda Boussoussou
MVMilán Vecsey-Nagy
Milán Vecsey-Nagy
MKMárton Kolossváry
Márton Kolossváry
BSBalint Szilveszter
Balint Szilveszter
Objectives: Dynamic myocardial CT perfusion (CTP) enables the functional assessment of coronary artery disease. We aimed to assess the impact of iterative reconstruction using hybrid- (HIR) and model-based iterative reconstruction (IMR) – as compared to filtered back projection (FBP) on CTP-derived myocardial blood flow (MBF). Methods: In our observational study we analyzed 35 patients who underwent dynamic myocardial CTP for the assessment of myocardial ischemia. Images were reconstructed using FBP, HIR and IMR algorithms. Qualitative and quantitative analysis of myocardial perfusion was performed by visual assessment and measurement of MBF on all reconstructed datasets. Image quality and interobserver variability were also assessed. Results: Mean MBF was 105.61 ± 27.54 mL/100 g min −1 for FBP, 105.07 ± 27.72 mL/100 g min −1 for HIR and 103.69 ± 27.62 mL/100 g min −1 for IMR, without significant differences between the algorithms ( P = 0.49). Image noise was significantly lower using novel iterative reconstructions compared to FBP (mean SDaorta: 48.3 ± 19.7 for FBP, 30.4 ± 13.3 for HIR and 19.5 ± 5.9 for IMR, P < 0.001 for all). Intraclass correlation coefficient for MBF was 0.96, while kappa value was 0.45 for visual assessment. Conclusion: Iterative reconstruction techniques reduce noise without altering MBF values of dynamic myocardial CTP. Therefore, further dose reduction may be achieved for dynamic myocardial CTP imaging.