Despite the significant medical and technical improvements in the field of dialytic renal replacement modalities, morbidity and mortality are excessively high among patients with end-stage kidney disease, and most interventional studies yielded disappointing results. Hemodiafiltration, a dialysis method that was implemented in clinics many years ago and that combines the two main principles of hemodialysis and hemofiltration—diffusion and convection—has had a positive impact on mortality rates, especially when delivered in a high-volume mode as a surrogate for a high convective dose. The achievement of high substitution volumes during dialysis treatments does not only depend on patient characteristics but also on the dialyzer (membrane) and the adequately equipped hemodiafiltration machine. The present review article summarizes the technical aspects of online hemodiafiltration and discusses present and ongoing clinical studies with regards to hard clinical and patient-reported outcomes.
The dialyzer is the core element in the hemodialysis treatment of patients with end-stage kidney disease (ESKD). During hemodialysis treatment, the dialyzer replaces the function of the kidney by removing small and middle-molecular weight uremic toxins, while retaining essential proteins. Meanwhile, a dialyzer should have the best possible hemocompatibility profile as the perpetuated contact of blood with artificial surfaces triggers complement activation, coagulation and immune cell activation, and even low-level activation repeated chronically over years may lead to undesired effects. During hemodialysis, the adsorption of plasma proteins to the dialyzer membrane leads to a formation of a secondary membrane, which can compromise both the uremic toxin removal and hemocompatibility of the dialyzer. Hydrophilic modifications of novel dialysis membranes have been shown to reduce protein adsorption, leading to better hemocompatibility profile and performance stability during dialysis treatments. This review article focuses on the importance of performance and hemocompatibility of dialysis membranes for the treatment of dialysis patients and summarizes recent studies on the impact of protein adsorption and hydrophilic modifications of membranes on these two core elements of a dialyzer.
Although high serum uric acid (SUA) has been consistently associated with an increased risk of death in the general population and in persons with nondialysis chronic kidney disease (CKD), studies in patients undergoing dialysis are conflicting. It has been postulated that low SUA simply reflects poor nutritional status in dialysis patients. We here characterize the association between SUA and the risk of death in a large dialysis cohort and explore effect modification by underlying nutritional status as reflected by body composition. In this retrospective cohort study, we included 16,057 hemodialysis (HD) patients treated during 2007 to 2016 in NephroCare centers as recorded in the European Clinical Database (EuCliD). The association between SUA, all-cause, and cardiovascular (CV)−related mortality was evaluated with competing risk models and characterized with splines. Effect modification was explored by lean tissue index (LTI) and fat tissue index (FTI). During a mean of 1.8 years of follow-up, 2791 patients (17.4%) died. We found a multivariable-adjusted U-shaped pattern between SUA and all-cause mortality. Patients with SUA levels of 6.5 mg/dl (387 μmol/l) were at the lowest risk of death (subdistribution hazard ratio = 0.94 [confidence interval {CI} 0.91; 0.96]). The form of association was not meaningfully affected by underlying LTI and FTI. We found a U-shaped pattern between SUA levels and all-cause mortality among HD patients, which was independent of the patients’ body composition.
Anemia is a major comorbidity of patients with end-stage renal disease and poses an enormous economic burden to health-care systems. High dose erythropoiesis-stimulating agents (ESAs) have been associated with unfavorable clinical outcomes. We explored whether mixed-dilution hemodiafiltration (Mixed-HDF), based on its innovative substitution modality, may improve anemia outcomes compared to the traditional post-dilution hemodiafiltration (Post-HDF). We included 174 adult prevalent dialysis patients (87 on Mixed-HDF, 87 on Post-HDF) treated in 24 NephroCare dialysis centers between January 2010 and August 2016 into this retrospective cohort study. All patients were dialyzed three times per week and had fistula/graft as vascular access. Patients were matched at baseline and followed over a one-year period. The courses of hemoglobin levels (Hb) and monthly ESA consumption were compared between the two groups with linear mixed models. Mean baseline Hb was 11.9±1.3 and 11.8±1.1g/dl in patients on Mixed- and Post-HDF, respectively. While Hb remained stable in patients on Mixed-HDF, it decreased slightly in patients on Post-HDF (at month 12: 11.8±1.2 vs 11.1±1.2g/dl). This tendency was confirmed by our linear mixed model (p = 0.0514 for treatment x time interaction). Baseline median ESA consumption was 6000 [Q1:0;Q3:16000] IU/4 weeks in both groups. Throughout the observation period ESA doses tended to be lower in the Mixed-HDF group (4000 [Q1:0;Q3:16000] vs 8000 [Q1:0;Q3:20000] IU/4 weeks at month 12; p = 0.0791 for treatment x time interaction). Sensitivity analyses, adjusting for differences not covered by matching at baseline, strengthened our results (Hb: p = 0.0124; ESA: p = 0.0687). Results of our explorative study suggest that patients on Mixed-HDF may have clinical benefits in terms of anemia management. This may also have a beneficial economic impact. Future studies are needed to confirm our hypothesis-generating results and to provide additional evidence on the potential beneficial effects of Mixed-HDF.