Background: Information about the cardiac manifestations of the Omicron variant of COVID‐19 is limited. We performed a systematic prospective echocardiographic evaluation of consecutive patients hospitalized with the Omicron variant of COVID‐19 infection and compared them with similarly recruited patients were propensity matched with the wild‐type variant. Methods and Results: A total of 162 consecutive patients hospitalized with Omicron COVID‐19 underwent complete echocardiographic evaluation within 24 hours of admission and were compared with propensity‐matched patients with the wild‐type variant (148 pairs). Echocardiography included left ventricular (LV) systolic and diastolic, right ventricular (RV), strain, and hemodynamic assessment. Echocardiographic parameters during acute infection were compared with historic exams in 62 patients with the Omicron variant and 19 patients with the wild‐type variant who had a previous exam within 1 year. Of the patients, 85 (53%) had a normal echocardiogram. The most common cardiac pathology was RV dilatation and dysfunction (33%), followed by elevated LV filling pressure (E/e′ ≥14, 29%) and LV systolic dysfunction (ejection fraction <50%, 10%). Compared with the matched wild‐type cohort, patients with Omicron had smaller RV end‐systolic areas (9.3±4 versus 12.3±4 cm 2 ; P =0.0003), improved RV function (RV fractional‐area change, 53.2%±10% versus 39.7%±13% [ P <0.0001]; RV S′, 12.0±3 versus 10.7±3 cm/s [ P =0.001]), and higher stroke volume index (35.6 versus 32.5 mL/m 2 ; P =0.004), all possibly related to lower mean pulmonary pressure (34.6±12 versus 41.1±14 mm Hg; P =0.0001) and the pulmonary vascular resistance index ( P =0.0003). LV systolic or diastolic parameters were mostly similar to the wild‐type variant‐matched cohort apart from larger LV size. However, in patients who had a previous echocardiographic exam, these LV abnormalities were recorded before acute Omicron infection, but not in the wild‐type cohort. Numerous echocardiographic parameters were associated with higher in‐hospital mortality (LV ejection fraction, stroke volume index, E/e′, RV S′). Conclusions: In patients with Omicron, RV function is impaired to a lower extent compared with the wild‐type variant, possibly related to the attenuated pulmonary parenchymal and/or vascular disease. LV systolic and diastolic abnormalities are as common as in the wild‐type variant but were usually recorded before acute infection and probably reflect background cardiac morbidity. Numerous LV and RV abnormalities are associated with adverse outcome in patients with Omicron.
Aims: Shift work disrupts the normal circadian rhythm and is associated with risk factors for coronary artery disease (CAD) and a higher incidence of CAD morbidity and mortality. Cardiac computed tomography angiography (CCTA) is a robust noninvasive modality for assessing the presence, extent, and severity of CAD. We sought to investigate whether shift workers are prone to a higher burden of CAD compared to non-shift workers. Methods: We conducted a historically prospective study in consecutive patients who underwent CCTA and answered a telephonic questionnaire. Due to significant differences in age and gender, we compared 89 well-matched pairs of shift workers and non-shift workers with the use of propensity scores. Results: Our cohort consisted of 349 participants, of whom 94 (26.9%) were shift workers. The mean age was 50.7 years, and 62.5% were males. After pairing, we showed that shift workers had a higher prevalence of CAD than non-shift workers (74.2 vs. 53.9%, respectively, p = 0.01), and a lower prevalence of coronary calcium scores of zero (46.8 vs. 63.4%, respectively, p = 0.034). Stenosis >50% was more prevalent in shift workers than in non-shift workers (20.2 vs. 11.2%, respectively, p = 0.006), and the extent of CAD (defined as the presence of ≥1-vessel disease) tended to be higher in shift workers than in non-shift workers (25.8 vs. 13.5%, respectively, p = 0.06). Conclusions: In this CCTA study, we showed in a well-matched cohort of consecutive patients that shift workers had a higher prevalence and extent of CAD than non-shift workers.
Acute kidney injury (AKI) is observed in up to 41% of patients undergoing transcatheter aortic valve implantation (TAVI) and is associated with increased risk for mortality. The aim of the present study is to evaluate whether furosemide-induced diuresis with matched isotonic intravenous hydration using the RenalGuard system reduces AKI in patients undergoing TAVI. Reduce-AKI is a randomized sham-controlled study designed to examine the effect of an automated matched hydration system in the prevention of AKI in patients undergoing TAVI. Patients will be randomized in a 1:1 fashion to the RenalGuard system (active group) versus non-matched saline infusion (sham-controlled group). Both arms receive standard overnight saline infusion and N-acetyl cysteine before the procedure. The Reduce-AKI trial will investigate whether the use of automated forced diuresis with matched saline infusion is an effective therapeutic tool to reduce the occurrence of AKI in patients undergoing TAVI. Clinicaltrials.gov: NCT01866800, 30 April 30 2013.
Summary: Background: Direct mechanical compression of the frame struts on the adjacent bundle branch with local inflammatory reaction might cause conduction system disturbances and need for pacemaker implantation following transcatheter aortic valve implantation (TAVI). We assessed the impact of preprocedural anti‐inflammatory steroid therapy on the occurrence of conduction disturbances following TAVI.Methods and results: From a cohort of 324 patients who underwent transfemoral TAVI, 39 (12%) were pretreated with steroids because of iodine allergy (n=29) or active obstructive pulmonary disease (n=10). We compared the rate of occurrence of new conduction disturbances and pacemaker implantation between TAVI patients with (n=39) and without (n=285) steroid treatment, using Cox logistic regression estimates and proportional hazards models. The overall occurrence of new conduction defects and the need for new pacemaker implantation were similar among steroid and non‐steroid‐treated patients (38.4% vs 37.5% and 25.6% vs 25.3%, respectively). New conduction disturbances were more prevalent in patients treated with CoreValve prosthesis, low implantation, and smaller aortic annulus diameter (P<.001, P<.001, and P=.006, respectively). Thirty‐day mortality and complication rates were similar between the groups.Conclusion: Although safe, steroid treatment prior to TAVI failed to reduce the incidence of new conduction defects and the need for pacemaker implantation.