Jan Luebke

Dr. Jan Luebke

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 July 2015 in Graefe's Archive for Clinical and Experimental Ophthalmology
Verified
Journal Article
Closed access
PDF file
AAAlexandra Anton
Alexandra Anton
SHSonja Heinzelmann
Sonja Heinzelmann
TNThomas Neß
Thomas Neß
Jan LuebkeJan Luebke
Jan Luebke
MNMatthias Neuburger
Matthias Neuburger
TWThomas Wecker
Thomas Wecker

1 July 2021 in Clinical Epidemiology
Verified
Journal Article
Open access
PDF file
Jan LuebkeJan Luebke
Jan Luebke
DBDaniel Boehringer
Daniel Boehringer
AAAlexandra Anton
Alexandra Anton
MDMoritz Daniel
Moritz Daniel
TRThomas Reinhard
Thomas Reinhard
SLStefan Lang
Stefan Lang
Background/Aims: Surgical procedures in ophthalmology underlie variations over different time periods and are strongly dependent on the technical process and the invention of innovative surgical techniques. Especially, in glaucoma surgery a lot of surgical devices and techniques have been introduced during the last years. Until now, the use of these newer techniques has not been shown on a robust data basis. We herein present the numbers of different types of glaucoma surgeries performed at German hospitals between 2006 and 2018. Methods and Design: The quality reports of hospitals in Germany from 2006 to 2018 were analyzed concerning all procedural codes for glaucoma surgery and intervention. Especially, the change in usage of “classical” and “modern” surgical techniques (MIGS: “minimally invasive glaucoma surgery”) or devices was compared. Results: The number of glaucoma procedures performed increased by 75% from 27,811 in 2006 to 48,794 in 2018. Absolute numbers of trabeculectomies, goniotomies, ab externo trabeculotomies and to a certain level cyclodestructive procedures decreased during the examined years while use of MIGS has increased in absolute and relative numbers since 2012. From 2015 a strong increase in the usage of XEN implants could be seen. Drainage implants (such as Baerveldt/Ahmed) showed stable absolute numbers over the time period covered. Absolute numbers of laser trabeculoplasty peaked in 2014 and decreased afterwards. Iridotomies and iridectomies increased by 120%/248% over the whole period. Conclusion: Our data show a trend towards the modern surgical options and especially MIGS during the recent years. Classical procedures showed a decrease in total numbers emphasized from 2013. These numbers confirm the assumption that modern glaucoma surgery is becoming more and more popular and established in German hospitals.

6 December 2017 in BMC Ophthalmology
Verified
Journal Article
Open access
PDF file
Jan LuebkeJan Luebke
Jan Luebke
TRThomas Reinhard
Thomas Reinhard
HAHansjuergen Agostini
Hansjuergen Agostini
DBDaniel Boehringer
Daniel Boehringer
PEPhilipp Eberwein
Philipp Eberwein
The dislocation of the crystalline lens is a common finding in patients with Marfan syndrome (MFS). Scleral intraocular lens (IOL) fixation is an accepted treatment method of this complication. To now, no long-term data on scleral IOL fixation in MFS exist. We present a retrospective study of 27 eyes of 17 MFS patients that underwent scleral lens fixation at our clinic between 1999 and 2012. These patients are compared to an age- and surgeon-matched group of 31 eyes of 27 patients who underwent the same procedure for reasons other than MFS. The median age in the MFS group was 35.4 years versus 35.6 years in the non-MFS group. The median follow-up was 4 years for MFS and 3 years for non-MFS. In the MFS group, significantly more IOL-dislocations occurred than compared to the non-MFS group (30% vs. 6.5%, p = 0.02). Retinal detachment occurred in four MFS-eyes compared to three eyes in the non-MFS group. Biometry prediction error was 1.11 diopters (D) for MFS and 1.33 D for non-MFS (p = 0.11). Median BCVA (best-corrected visual acuity, logMAR) was 0.1 in the MFS group versus 0.3 in non-MFS patients. Scleral lens fixation in MFS patients achieves satisfying visual and refractive outcomes. Our data shows a significantly higher rate of IOL dislocations in patients with MFS. We therefore recommend addressing this complication preoperatively.

9 February 2019 in Graefe's Archive for Clinical and Experimental Ophthalmology
Verified
Journal Article
Closed access
PDF file
MAMarkus Avar
Markus Avar
JJJens F. Jordan
Jens F. Jordan
MNMatthias Neuburger
Matthias Neuburger
DEDiana Engesser
Diana Engesser
Jan LuebkeJan Luebke
Jan Luebke
TWThomas Wecker
Thomas Wecker

4 December 2014 in Graefe's Archive for Clinical and Experimental Ophthalmology
Verified
Journal Article
Closed access
PDF file
Jan LuebkeJan Luebke
Jan Luebke
DBD. Boehringer
D. Boehringer
MNM. Neuburger
M. Neuburger
AAA. Anton
A. Anton
TWT. Wecker
T. Wecker
JJJ. F. Jordan
J. F. Jordan

1 September 2016 in Journal of Glaucoma
Verified
Journal Article
Closed access
TWThomas Wecker
Thomas Wecker
MNMatthias Neuburger
Matthias Neuburger
LBLaura Bryniok
Laura Bryniok
KBKathrin Bruder
Kathrin Bruder
Jan LuebkeJan Luebke
Jan Luebke
JJJens F. Jordan
Jens F. Jordan
Purpose: Uncontrolled intraocular pressure (IOP) after glaucoma filtration surgery is a challenging problem in the management of glaucoma patients. The Trabectome is a device for selective electroablation of the trabecular meshwork through a clear cornea incision without affecting the conjunctiva. Minimally invasive glaucoma surgery using the Trabectome is safe and effective as primary glaucoma surgery. Here we investigate the results of ab interno trabeculectomy with the Trabectome for IOP control in patients with a failed filtering bleb. Methods: A total of 60 eyes of 60 consecutive patients with primary open-angle glaucoma (POAG) or pseudoexfoliative glaucoma (PXG) were enrolled in this single center observational study. Trabectome surgery was performed alone or in combination with phacoemulsification by 2 experienced surgeons. IOP readings and number of IOP lowering medication as primary outcome parameters were taken by an independent examiner. Intraoperative and postoperative medication were recorded systematically. Results: Mean IOP before surgery was 24.5±3.5 mm Hg and decreased to 15.7±3.4 (−36%) after mean follow-up of 415 days. The number of necessary IOP lowering medication dropped from 2.1±1.3 to 1.8±1.2 (14% reduction from baseline). A total of 25% (n=15) of cases reported here needed additional surgery after 517 days (range: 6 to 1563 d). No major complications were observed. After mean follow-up, we found a qualified success rate for PXG of 87% and 50% for POAG as revealed by the Kaplan-Meier analysis according to the definitions for success in advanced glaucoma cases according to the World Glaucoma Association (40% reduction from baseline IOP and maximum IOP of 15 mm Hg). Discussion: Trabectome surgery for uncontrolled IOP after trabeculectomy is safe and effective especially in PXG patients. Given the demanding subgroup of patients studied here, it is not surprising that success rates are lower compared with previous studies investigating the Trabectome for primary glaucoma surgery. The number of necessary IOP lowering medication drops at first, but seems to reach preoperative values after 20 months of follow-up. Trabectome surgery should be considered as a valuable escape procedure for patients with failed filtering blebs and uncontrolled IOP.