Cone-beam computed tomography (CBCT) amounts to an excellent diagnostic tool to evaluate the peri-implant bone thickness in all dimensions. Despite the unquestionable advantages of CBCT, potential artifacts around dental implants might disturb the proper assessment of the surrounding structures. The artifacts may mask osseointegration, shallow bone defects, and other types of radiolucency, which make it difficult to establish an early diagnosis of bone loss. Proper diagnosis of bone defect is necessary to decide about surgical intervention. The aim of this literature review is to assess the CBCT exposure causing artifacts on the peri-implant structures. An electronic search of MEDLINE (PubMed) database includes studies published before July 2021 and supplemented by manual research. Clinical, ex vivo, in vitro, and animal studies evaluating the relationship between exposition parameters and occurrence of artifacts around the dental implant in CBCT studies were included. A literature review revealed that kilovoltage, tube current, and field of view may affect the occurrence of artifacts around dental implants, all of which would compromise radiological evaluation. Therefore, it is feasible to reduce the incidence of artifacts and improve the image quality by appropriate modification of the exposure parameters. However, the reduction of artifacts is often associated with a significant increase in radiation exposure; hence, an effort should be made to minimize the radiation dose in line with the ALARA (as low as reasonably achievable) principle.
The aim of this study was to assess the impact of dimensional distortion and its changes with modification of exposure setting parameters on the measurements of peri-implant bone margin. Ten titanium dental implants (InKone Primo, Global D, Paris, France) were placed in two prepared bovine ribs. Two bone models and an implant-with-transfer model were scanned with 3shape E4 (3shape, Copenhagen, Denmark) laboratory scanner. Cone beam computed tomography (CBCT) images of two bone models were taken with different values of voltage (60, 70, 80, 90 kV), tube current (4, 10 mA) and voxel size (200, 300 µm). All the data were superimposed using planning software, and the measurements of buccal bone thickness in two selected regions were performed both using CBCT and scan cross-sections. The mean squared error (MSE) being the squared differences between measurements was used in the accuracy assessment of the CBCT device. A one-way ANOVA revealed significant differences between voltage and MSE (p = 0.044), as well as implant position and MSE (p = 0.005). The distortions of measurements depend on bone margin thickness, and the higher the distance to measure, the higher the error. Accurate measurements of buccal bone thickness (MSE below 0.25) were achieved with voltage values of 70, 80, and 90 kV.