ning zhang

Dr. ning zhang

School of Electrical Engineering and Automation, Anhui University, Hefei 230601, Anhui, China

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 June 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
JYJinke Yao
Jinke Yao
JXJiachen Xu
Jiachen Xu
ning zhangning zhang
ning zhang
Yajuan GuanYajuan Guan
Yajuan Guan
Due to the uncertainty and randomness of clean energy, microgrid operation is often prone to instability, which requires the implementation of a robust and adaptive optimization scheduling method. In this paper, a model-based reinforcement learning algorithm is applied to the optimal scheduling problem of microgrids. During the training process, the current learned networks are used to assist Monte Carlo Tree Search (MCTS) in completing game history accumulation, and updating the learning network parameters to obtain optimal microgrid scheduling strategies and a simulated environmental dynamics model. We establish a microgrid environment simulator that includes Heating Ventilation Air Conditioning (HVAC) systems, Photovoltaic (PV) systems, and Energy Storage (ES) systems for simulation. The simulation results show that the operation of microgrids in both islanded and connected modes does not affect the training effectiveness of the algorithm. After 200 training steps, the algorithm can avoid the punishment of exceeding the red line of the bus voltage, and after 800 training steps, the training result converges and the loss values of the value and reward network converge to 0, showing good effectiveness. This proves that the algorithm proposed in this paper can be applied to the optimization scheduling problem of microgrids.

25 July 2025 in Sustainability
Verified
Journal Article
Open access
PDF file
LSLei Su
Lei Su
WFWangli Feng
Wangli Feng
CKCao Kan
Cao Kan
MWMingjiang Wei
Mingjiang Wei
RSRui Su
Rui Su
ning zhangning zhang
ning zhang
To address the challenges posed by the instability of renewable energy output and load fluctuations on grid operations and to support the low-carbon sustainable development of the energy system, this paper integrates artificial intelligence technology to establish an economic stability dispatch framework for distributed resource aggregators. A phased multi-contract collaborative scheduling model oriented toward sustainable development is proposed. Through intelligent algorithms, the model dynamically optimises decisions across the day-ahead and intraday phases: During the day-ahead scheduling phase, intelligent algorithms predict load demand and energy output, and combine with elastic performance-based response contracts to construct a user-side electricity consumption behaviour intelligent control model. Under the premise of ensuring user comfort, the model generates a 24 h scheduling plan with the objectives of minimising operational costs and efficiently integrating renewable energy. In the intraday scheduling phase, a rolling optimisation mechanism is used to activate energy storage capacity contracts and dynamic frequency stability contracts in real time based on day-ahead prediction deviations. This efficiently coordinates the intelligent frequency regulation strategies of energy storage devices and electric vehicle aggregators to quickly mitigate power fluctuations and achieve coordinated control of primary and secondary frequency regulation. Case study results indicate that the intelligent optimisation-driven multi-contract scheduling model significantly improves system operational efficiency and stability, reduces system operational costs by 30.49%, and decreases power purchase fluctuations by 12.41%, providing a feasible path for constructing a low-carbon, resilient grid under high renewable energy penetration.

6 July 2026 in Sustainability
Verified
Journal Article
Open access
PDF file
YLYixian Li
Yixian Li
XZXudong Zhu
Xudong Zhu
LYLingxiao Yang
Lingxiao Yang
ning zhangning zhang
ning zhang
Reliable state estimation is essential for the secure and efficient operation of sustainable energy systems, especially under the increasing integration of renewable energy, distributed resources, and heterogeneous sensing devices. However, in practical power systems, SCADA, PMU, and AMI measurements often have different sampling rates, accuracies, communication delays, and availability levels, which makes reliable data completion and multi-source fusion difficult. This paper focuses on the state estimation problem of renewable-integrated distribution networks under multi-source heterogeneous measurement conditions. In such distribution networks, the increasing penetration of distributed renewable energy resources and the joint deployment of multiple measurement devices, including SCADA, PMU, and AMI, may lead to incomplete measurements, asynchronous sampling, differences in measurement accuracy, and reduced system observability. To address these issues, this paper proposes a model-based digital twin reference-guided physics-constrained DDPM framework to improve the quality of missing-measurement completion and the reliability of state estimation in distribution-network scenarios. A four-layer simulation-oriented cyber–physical framework is first constructed to integrate physical sensing, model-based digital twin reference mapping, AI-based measurement completion, and state estimation feedback. Within this framework, a physics-constrained self-supervised denoising diffusion probabilistic model is developed to recover missing measurements by combining observed data, digital twin reference measurements, real-time topology information, and power system operational constraints. The completed pseudo-measurements and physical measurements are then fused through a credibility-aware weighting strategy that considers timeliness, data integrity, measurement accuracy, and virtual–real consistency verification under simulation settings. Simulation results on the IEEE 14-bus system show that the proposed method improves pseudo-measurement completion and supports more reliable voltage magnitude and phase angle estimation under different measurement configurations. Under the tested simulation settings and multi-source measurement configurations, the results indicate that the proposed method can improve pseudo-measurement completion and support more reliable voltage magnitude and phase angle estimation. However, its performance under frequent topology switching, high missing-data ratios, and complex abnormal data conditions remains to be further evaluated.