Since the beginning of measurement of pressure in the 17th century, the unit of pressure has been defined by the relationship of force per unit area. The present state of optical technology now offers the possibility of using a thermodynamic definition—specifically the ideal gas law—for the realization of the pressure unit, in the vacuum regime and slightly above, with an accuracy comparable to or better than the traditional methods of force per area. The changes planned for the SI in 2018 support the application of this thermodynamic definition that is based on the ideal gas law with the necessary corrections for real-gas effects. The paper reviews the theoretical and experimental foundations of those optical methods that are considered to be most promising to realize the unit of pressure at the highest level of metrology.
The maximal liver function capacity (LiMAx) test, a novel 13 C-methacetin breath test, has proven clinical validity in determining hepatic metabolic capacity. In contrast to prior 13 C-methacetin breath test protocols, the LiMAx test is performed by intravenous body-weight-adjusted substrate administration. Furthermore, the DOB kinetics (delta over baseline of the time-dependent exhaled 13 CO 2 / 12 CO 2 ratio) are measured online at the bedside with a high time resolution in order to determine the maximum DOB. The aim of this study was to analyze the recorded DOB kinetics in a large population for further refinement of the test protocol. Two new methods of kinetic analysis are proposed in this article: the time dependency of the DOB kinetics and the time interval until half of the DOB maximum. A total of 10 100 LiMAx tests on 8483 patients performed during routine clinics at eight centers were available. The kinetic analysis revealed a specific pattern of DOB kinetics depending upon LiMAx result. In addition, potential co-factors for DOB kinetics, such as weight, height, gender and age, were analyzed, yielding a potential influence of gender and smoking behavior. Both the specific patterns and the proposed kinetic analysis have the potential to further improve the sensitivity and specificity of the test and its clinical applicability by shortening its duration.
We have developed a flow-through fast liver investigation packet (FLIP) to quantitatively measure the amount of exhaled (13)CO(2), as a result of liver metabolization processes. The FLIP system allows investigation of every single breath in real time. Line width variations due to interactions with other gas components disturb traditional measurements and limit their sensitivity to the ppm range. Detection of the complete breath volume and the spectrally fully resolved line shape allows sensitivity in the ppb range with a standard deviation of approximately 80 ppb, a prerequisite to quantitatively analyze liver metabolization processes.