Introduction: The aim of this study was to assess if the complex anatomy of aortic aneurysm and aortic dissection can be accurately reproduced from a contrast‐enhanced computed tomography (CT) scan into a three‐dimensional (3D) printed model.Methods: Contrast‐enhanced cardiac CT scans from two patients were post‐processed and produced as 3D printed thoracic aorta models of aortic aneurysm and aortic dissection. The transverse diameter was measured at five anatomical landmarks for both models, compared across three stages: the original contrast‐enhanced CT images, the stereolithography (STL) format computerised model prepared for 3D printing and the contrast‐enhanced CT of the 3D printed model. For the model with aortic dissection, measurements of the true and false lumen were taken and compared at two points on the descending aorta.Results: Three‐dimensional printed models were generated with strong and flexible plastic material with successful replication of anatomical details of aortic structures and pathologies. The mean difference in transverse vessel diameter between the contrast‐enhanced CT images before and after 3D printing was 1.0 and 1.2 mm, for the first and second models respectively (standard deviation: 1.0 mm and 0.9 mm). Additionally, for the second model, the mean luminal diameter difference between the 3D printed model and CT images was 0.5 mm.Conclusion: Encouraging results were achieved with regards to reproducing 3D models depicting aortic aneurysm and aortic dissection. Variances in vessel diameter measurement outside a standard deviation of 1 mm tolerance indicate further work is required into the assessment and accuracy of 3D model reproduction.
Three‐dimensional (3D) printing and medical imaging have a complementary association, the benefits and application areas of which are increasingly documented and further illustrated in this journal publication. Medical imaging data can be appropriately processed (i.e. segmented) to provide the geometric information from which accurate and realistic 3D medical models can be generated. The resulting models can be printed in a range of different materials to suit their use as phantoms in medical radiation and imaging studies, for medical imaging education and training or patient communication.
Background: Three-dimensional (3D) printing is promising in medical applications, especially presurgical planning and the simulation of congenital heart disease (CHD). Thus, it is clinically important to generate highly accurate 3D-printed models in replicating cardiac anatomy and defects. The present study aimed to investigate the accuracy of the 3D-printed CHD model by comparing them with computed tomography (CT) images and standard tessellation language (STL) files. Methods: Three models were printed, comprising different CHD pathologies, including the tetralogy of Fallot (ToF), ventricular septal defect (VSD) and double-outlet right-ventricle (DORV). The ten anatomical locations were measured in each comparison. Pearson’s correlation coefficient, Bland–Altman analysis and intra-class correlation coefficient (ICC) determined the model accuracy. Results: All measurements with three printed models showed a strong correlation (r = 0.99) and excellent reliability (ICC = 0.97) when compared to original CT images, CT images of the 3D-printed models, STL files and 3D-printed CHD models. Conclusion: This study demonstrated the high accuracy of 3D-printed heart models with excellent correlation and reliability when compared to multiple source data. Further investigation into 3D printing in CHD should focus on the clinical value and the benefits to patients.
Twenty-first-century mining is a complex pursuit. Stakeholders must manage many interconnected processes and data sets to ensure an operation is sustainable. Mixed Reality (MR) simulation may present an opportunity to improve knowledge and understanding of mine operations via a digital twin. Current and future personnel can model and make predictions using past, current and future data sets. However, MR is still an uncommon tool in the mining industry. This paper asks why that is the case, what some common barriers may be to MR adoption, and presents a possible collaborative solution to make MR sustainable as the technology gains hold and becomes commonplace in mine operations and elsewhere.