Lukáš Pazourek

Dr. Lukáš Pazourek

Masaryk University, Brno, Jihomoravský Kraj, Czech Republic
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 July 2021 in Cancers
Verified
Journal Article
Open access
PDF file
Michal MahdalMichal Mahdal
Michal Mahdal
JNJakub Neradil
Jakub Neradil
PMPeter Múdrý
Peter Múdrý
SPSilvia Paukovčeková
Silvia Paukovčeková
IZIva Staniczkova Zambo
Iva Staniczkova Zambo
RVRenata Veselska
Renata Veselska
Giant-cell tumor of bone (GCTB) is an intermediate type of primary bone tumor characterized by locally aggressive growth with metastatic potential. The aim of this study was to identify new druggable targets among the cell signaling molecules involved in GCTB tumorigenesis. Profiles of activated signaling proteins in fresh-frozen tumor samples and tumor-derived cell lines were determined using phosphoprotein arrays. Analysis of the obtained data revealed epidermal growth factor receptor (EGFR) and platelet-derived growth factor receptor beta (PDGFRβ) as potential targets, but only the PDGFR inhibitor sunitinib caused a considerable decrease in stromal cell viability in vitro. Furthermore, in the case of a 17-year-old patient suffering from GCTB, we showed that the addition of sunitinib to the standard treatment of GCTB with the monoclonal antibody denosumab resulted in the complete depletion of multinucleated giant cells and mononuclear stromal cells in the tumor tissue. To summarize, the obtained data showed that a specific receptor tyrosine kinase (RTK) signaling pattern is activated in GCTB cells and plays an important role in the regulation of cell proliferation. Thus, activated RTKs and their downstream signaling pathways represent useful targets for precision treatment with low-molecular-weight inhibitors or with other types of modern biological therapy.

13 May 2022 in Current Oncology
Verified
Journal Article
Open access
PDF file
Michal MahdalMichal Mahdal
Michal Mahdal
LPLukáš Pazourek
Lukáš Pazourek
Vasileios ApostolopoulosVasileios Apostolopoulos
Vasileios Apostolopoulos
DKDagmar Adámková Krákorová
Dagmar Adámková Krákorová
IZIva Staniczková Zambo
Iva Staniczková Zambo
TTTomas Tomas
Tomas Tomas
Background: The purpose of this study was to evaluate the implant survival, functional score and complications of intercalary endoprostheses implanted for metastatic involvement of the femoral and humeral diaphysis. Methods: The selected group covered patients with bone metastasis who were surgically treated with an intercalary endoprosthesis between 2012 and 2021. The functional outcome was evaluated with the Musculoskeletal Tumor Society (MSTS) scoring system, and complications were evaluated by using the failure classification for prosthetics designed by Henderson. Results: The mean follow-up was 29.8 months. In our group of 25 patients with 27 intercalary endoprostheses (18 femurs, 9 humeri), there were 7 implant-related complications (25.9%), which were more common on the humerus (4 cases, 44.4%) than on the femur (3 cases, 16.7%). Only type II failure—aseptic loosening (5 cases, 18.5%)—and type III failure—structural failure (2 cases, 7.4%)—occurred. There was a significantly higher risk of aseptic loosening of the endoprosthesis in the humerus compared with that in the femur (odds ratio 13.79, 95% confidence interval 1.22–151.05, p = 0.0297). The overall cumulative implant survival was 92% 1 year after surgery and 72% 5 years after surgery. The average MSTS score was 82%. The MSTS score was significantly lower (p = 0.008) in the humerus (75.9%) than in the femur (84.8%). Conclusions: The resection of bone metastases and replacement with intercalary endoprosthesis has excellent immediate functional results with an acceptable level of complications in prognostically favourable patients.

18 April 2023 in International Orthopaedics
Verified
Journal Article
Open access
PDF file
Vasileios ApostolopoulosVasileios Apostolopoulos
Vasileios Apostolopoulos
LNLuboš Nachtnebl
Luboš Nachtnebl
Michal MahdalMichal Mahdal
Michal Mahdal
LPLukáš Pazourek
Lukáš Pazourek
PBPetr Boháč
Petr Boháč
TTTomas Tomas
Tomas Tomas
Purpose: This study aims to compare total knee replacement (TKA) with NexGen All-Poly (APT) and NexGen Metal-Backed (MBT) in terms of implant survivorship, reasons leading to implant failure and functional results of defined age categories. Methods: A single-centre, retrospective evaluation of 812 patients who underwent knee replacement with NexGen CR between 2005 and 2021, comparing a modern congruent APT component to a modular MBT equivalent component using a similar surgical technique at a notable mean follow-up duration. Implant survival, functional outcomes using the Knee Society Score and range of motion were evaluated and compared in different age categories. Results: Of the 812 NexGen CR TKAs performed at our institution, 410 (50.4%) used APT components and 402 (49.6%) MBT components. The survival rate of NexGen APT was 97.1% and that of NexGen MBT was 93.2% (p = 0.36). Removal of the implant occurred overall in 15 cases, for MBT in ten cases, and for APT in four cases. The FS was proved to be significantly higher when APT components were implanted in younger patients than for MBT (p = 0.005). A similar range of motion between the components was recorded (p = 0.1926). Conclusion: Under defined conditions, we measured the clinical results of implants from a single manufacturer implanted in a single department using a similar surgical technique. Considering the limitations, we suggest that all-polyethylene tibial components are equal or even superior to metal-backed ones across the examined age categories.

21 September 2023 in Cancers
Verified
Journal Article
Open access
PDF file
Michal MahdalMichal Mahdal
Michal Mahdal
TTTomas Tomas
Tomas Tomas
Vasileios ApostolopoulosVasileios Apostolopoulos
Vasileios Apostolopoulos
DADagmar Adámková
Dagmar Adámková
PMPeter Múdrý
Peter Múdrý
LPLukáš Pazourek
Lukáš Pazourek
Giant cell tumour of bone (GCTB) is one of the most common local aggressive tumourous lesions with a wide variety of biological behaviour. However, there are no clear indicative criteria when choosing the type of procedure and the complication rates remain high, especially in terms of local recurrence. The purpose of the study was to (1) identify the main risk factors for local recurrence, (2) evaluate the recurrence-free survival in dependence on neoadjuvant denosumab use and the type of procedure, and (3) compare the functional outcomes after curettage and en bloc resection. The group included 102 patients with GCTB treated between 2006 and 2020. The mean age of patients was 34.4 years (15–79). The follow-up period was 8.32 years (2–16) on average. Local recurrence occurred in 14 patients (29.8%) who underwent curettage and in 5 patients (10.6%) after en bloc resection. Curettage was shown to be a factor in increasing recurrence rates (OR = 3.64 [95% CI: 1.19–11.15]; p = 0.023). Tibial location was an independent risk factor for local recurrence regardless of the type of surgery (OR = 3.22 [95% CI: 1.09–9.48]; p = 0.026). The recurrence-free survival rate of patients treated with resection and denosumab was higher compared to other treatments at five years postoperatively (p = 0.0307). Functional ability and pain as reported by patients at the latest follow-up were superior after curettage compared to resection for upper and lower extremity (mean difference: −4.00 [95% CI: –6.81 to −1.18]; p < 0.001 and mean difference: −5.36 [95% CI: −3.74 to −6.97]; p < 0.001, respectively). Proximal tibia tumour location and curettage were shown to be major risk factors for local recurrence in GCTB regardless of neoadjuvant denosumab treatment. The recurrence-free survival rate of patients treated with resection and denosumab was higher compared to other treatments. The functional outcome of patients after curettage was better compared to en bloc resection.

14 May 2024 in Annals of Surgical Oncology
Verified
Journal Article
Open access
PDF file
Vasileios ApostolopoulosVasileios Apostolopoulos
Vasileios Apostolopoulos
PBPetr Boháč
Petr Boháč
PMPetr Marcián
Petr Marcián
IZIva Staniczkova Zambo
Iva Staniczkova Zambo
LPLukáš Pazourek
Lukáš Pazourek
TTTomas Tomas
Tomas Tomas
Background and Objectives: Curettage is the removal of a tumor from the bone while preserving the surrounding healthy cortical bone, and is associated with higher rates of local recurrence. To lower these rates, curettage should be combined with local adjuvants, although their use is associated with damage to nearby healthy bone. Objective: The purpose of this analysis is to determine the effect of local adjuvants on cortical porcine bone by using micro-computed tomography (micro-CT) along with histological and mechanical examination. Methods: Local adjuvants were applied to porcine specimens under defined conditions. To assess changes in bone mineral density (BMD), a micro-CT scan was used. The pixel gray values of the volume of interest (VOI) were evaluated per specimen and converted to BMD values. The Vickers hardness test was employed to assess bone hardness (HV). The depth of necrosis was measured histologically using hematoxylin and eosin-stained tissue sections. Results: A noticeable change in BMD was observed on the argon beam coagulation (ABC) sample. Comparable hardness values were measured on samples following electrocautery and ABC, and lowering of bone hardness was obtained in the case of liquid nitrogen. Extensive induced depth of necrosis was registered in the specimen treated with liquid nitrogen. Conclusion: This study determined the effect of local adjuvants on cortical bone by using micro-CT along with histological and mechanical examination. Phenolization and liquid nitrogen application caused a decrease in bone hardness. The bone density was affected in the range of single-digit percentage values. Liquid nitrogen induced extensive depth of necrosis with a wide variance of values.

30 November 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
LNLuboš Nachtnebl
Luboš Nachtnebl
Vasileios ApostolopoulosVasileios Apostolopoulos
Vasileios Apostolopoulos
Michal MahdalMichal Mahdal
Michal Mahdal
LPLukáš Pazourek
Lukáš Pazourek
PBPavel Brančík
Pavel Brančík
TTTomas Tomas
Tomas Tomas
Numerous studies have compared metal-backed components (MBTs) and all-polyethylene tibial components (APTs), but none of them specifically analysed the clinical results and the overall patient preference in patients who had undergone a staged bilateral knee replacement. The purpose of this study is to compare clinical results, perceived range of motion, and overall implant preference among patients who had undergone staged bilateral knee replacement with an APT and contralateral knee replacement with MBTs. A dataset of 62 patients from a single centre who underwent staged bilateral TKA between 2009 and 2022 was selected and retrospectively analysed. Tibial component removal was performed in three knees overall, all of which had MBTs. The mean measured Knee Score (KS) of knees with APTs was 78.37 and that of contralateral knees with MBTs was 77.4. The mean measured Function (FS) of knees with APTs was 78.22, and that of contralateral knees with MBs was 76.29. The mean flexion angle of knees with APTs was 103.8 and that for knees with MBTs was 101.04 degrees. A total of 54.8% of the patients preferred the knee that received APTs over contralateral MBTs. In our cohort, TKA with an APT in one knee and an MBT in the contralateral knee recorded similar clinical results and perceived ranges of motion. Patients in general preferred the knee that received an APT over contralateral knee with an MBT.