We report an experimental study on the gain of the Raman signal of aqueous mixtures and liquid water when confined in aerogel-lined capillaries of various lengths of up to 20 cm and various internal diameters between 530 and 1000 µm. The lining was made of hydrophobised silica aerogel, and the carrier capillary body consisted of fused silica or borosilicate glass. Compared to the Raman signal detected from bulk liquid water with the same Raman probe, a Raman signal 27 times as large was detected when the liquid water was confined in a 20 cm-long capillary with an internal diameter of 700 µm. In comparison with silver-lined capillaries of the same length and same internal diameter, the aerogel-lined capillaries featured a superior Raman signal gain and a longer gain stability when exposed to mixtures of water, sugar, ethanol and acetic acid.
An advanced process for the manufacturing of aerogel-lined capillaries is presented; these are applicable as liquid-core waveguides for gaining the Raman signal of aqueous samples. With respect to the spin-coating process we have used so far for the manufacturing of aerogel-lined capillaries, the here-presented manufacturing process is advanced as it enables (i) the lining of longer capillaries, (ii) the adjustment of the lining-thickness via the lining velocity, and (iii) the reproducible generation of crack-free linings. The key parameters of the advanced process and their effect on the fabrication of aerogel-lined capillaries with optimal Raman signal gain are reported and related to the thickness and topography of the aerogel linings by the support of scanning electron microscopy.
18 July 2025 in Analytical and Bioanalytical Chemistry
We compare particulate versus monolithic silica aerogel-lined capillaries as liquid core waveguides for Raman signal gain of liquid aqueous samples. The manufacturing process of monolithic linings, which aims to address the limited robustness of particulate aerogel linings, is discussed in detail and compared with that of particulate linings. The linings of both capillary types are characterized using scanning electron microscopy. Raman signal gain of pure water and aqueous solutions is evaluated for each type. The aqueous solutions are samples drawn at different times from the oxidative conversion of glycerol to formic acid (OxFA process). It is analyzed whether the Raman signal gain provided by aerogel-lined capillaries is affected by the property changes in this exemplary industrial process caused by the ongoing chemical reaction. Finally, the mechanical robustness of the linings and the stability of the Raman signal gain are tested under rapid and repeated capillary purge in both types. Graphical Abstract